Page 2
iba AG 2009 all rights reserved. ibaFOB-4i-X - Manual V 2.3 en / ibaFOB A2/A1 We have checked that the contents of this manual match the hardware and software de- scribed here. However, deviations cannot be fully ruled out, so that we cannot assume any warranty should any deviations actually exist.
Installing the Card ............... 10 Removing the Card ..............11 Installation of drivers Windows XP ................12 System Integration Sample Topologies with ibaFOB-4i-X .......... 14 7.1.1 Operation for data acquisition ..............14 7.1.2 Operation with ibaLogic (Vibration Monitoring, Bearing Monitoring) ..14 7.1.3 Operation with ibaPDA-V6 in X-Mode............15...
Page 4
Page 4 Manual ibaFOB-4i-X Support and Contact iba AG 2012...
A reference to additional documentation or more in-depth literature. iba training courses Hint for training courses by iba concerning related products or subjects Copyright notice Windows is a registered trademark of Microsoft Corporation. Other product or company names mentioned in this manual may be brand names or reg- istered trademarks of the corresponding owner.
On one hand these are devices from iba which care the "X" in the name and on the other hand system components of other manufacturers like ABB AC 800 PEC or Simatic TDC with LO5A interface.
What's new? The ibaFOB-4i-X and respectively the ibaFOB-2io-X and ibaFOB-2i-X card represent the new generation of iba's fiber optic PC boards. These boards extend the existing board family and will replace the previous ibaFOB-cards in long-term. The new boards are 100% compatible on the fiber optical bus side while in the PC the interface and dual port ram layout differ between the old and new boards.
Manual ibaFOB-4i-X Scope of Delivery The following components are included with the delivery. ibaFOB-4i-X device Flat ribbon cable with four jacks for iba card interrupt synchronization Manual Safety Information Please consider the following safety advises: W A R N I N G! To avoid electrical shock during installation or uninstallation of the device disconnect the power supply from the computer before opening.
Please see http://www.iba-ag.com for further details on a properly outfitted workstation. Recommendation for operation of two ibaFOB-4i-X (= 8 FO-links) with 32 Mbit/s. Lower requirements, lower transmission rates or less links permit use of PCs with lower performance. Software Microsoft Windows 2000, XP or 2003 Server ...
Stop and switch off the computer, disconnect it from the power supply and open it. Release the screw in the front panel. Pull out the card off the PCI slot carefully and put in a safe place or conduc- tive plastic bag. iba AG 2012...
Installation of drivers Windows XP The ibaFOB-4i-X cards comply to the plug and play conventions of Windows. After the first-time installation of the card and booting of the computer the hardware in- stallation wizard pops up and guides you through the next steps of the installation proc- ess.
Page 13
Manual Page 13 The system searches the driver software and installs it automatically. After, click on <Finish>. In the Windows device manager you can check if the card has been detected and in- stalled correctly. iba AG 2012...
No jumpers or DIL switches, all parameters are software controlled (the switch on top of the board is for iba internal use only); interrupt synchronization cable to con- nect multiple iba cards in one PC Dynamic reassigning of interrupt sources and interrupt generation (board and driver ...
Page 17 Views, Displays and Connectors Connector for ibaFOB-4o-X for monitoring of input signals Connector for ibaFOB-4o-X for output signals Power supply for Sync-i / Sync-o- modules Sync-IRQ-connector 7-Segment display LEDs (4 x) Receivers (4 x) iba AG 2012...
(dot is off). 8.3.3 Fiber Optic Interface of ibaFOB-4i-X The ibaFOB-4i-X provides four ST type jacks (grey) for the fiber optic receivers. If the card was configured for external synchronization, e. g. for operation with an ibaBM-SLM, the first (top) input channel needs to be connected with the external device for proper function (otherwise the whole PC process will be stopped).
512 analog and 512 digital in- put channels, with practically no delay. To do this connect the ibaFOB-4o-X to the ibaFOB-4i-X on the light grey 14-pin connec- tor. The ibaFOB-4o-X module mirrors the input and output signals.
For applications which require only two in-/output channels, the use of the ibaFOB-2io-X is recommended. If the module is used for mirror function then another iba system may be supplied with the same input signals, e. g. ibaPDA and ibaLogic. Therefore, connect the module with the light grey 14-pin connector on the ibaFOB-2io-X or ibaFOB-4i-X card.
9.1.1 Configuration of the Card If an ibaFob-2io-X or ibaFob-4i-X card is installed, you'll find an additional tab FOB in the General dialog. These settings apply to measurements with high data rate only. If you use the card in F- mode the settings are not relevant.
Page 22
If you mark the sub branches with the links you'll get further information about the proc- essors. There are different sets of information, depending on whether a link is operating in X- mode or F-/M-mode. a) Link operating in F-Mode (with ibaPADU-8) iba AG 2012...
Page 23
If you open the "link"-branches you can see the connected devices (= modules). Each link is subdivided in eight groups of eight channels each (64 in total per link) which corre- sponds to the smallest information package in the ibaPADU-8 philosophy. iba AG 2012...
In the signal tables you can give a name to the signals assign physical units and limit val- ues (Max, Min) or set the signals active or passive. The column Actual shows already in- coming values when an active device is physically connected. Further information finds you in the manual ibaPDA-V6. iba AG 2012...
FobFast module should be added to the corresponding link. The module type is only available if an ibaFob-2io-X or ibaFob-4i-X card is installed. Fob Fast modules can only be connected to links which are configured for high data rate mode.
Page 26
By selection of the link mode, i. e. data types, the signal tables of analog signals will be adjusted automatically. (Integer: Min / Max; Real: Gain / Offset) iba AG 2012...
Page 27
The signal tables for the analog and digital signals will be adjusted automatically. Moreover, you may specify the position in the telegram and the datatype of each signal in the signal tables. iba AG 2012...
Page 28
Link mode Address offset for digital signals 64 Int 0xC0 128 Int / 64 Real 0x140 256 Int / 128 Real 0x240 512 Int / 256 Real 0x440 1024 Int / 512 Real 0x840 1024 Real 0x1040 iba AG 2012...
Page 29
WORD, 2 Byte -value DWORD, 4 Byte-value BYTE, 1 Byte FLOAT, 4 Byte floating point value (real) It might be necessary to adjust the addresses after a change with respect to the data type. iba AG 2012...
The main branch General in the tree view, tab Interrupt Info, shows the interrupt counter. The counter iba-Interrupts must have 1000 increments per second! If not, the interrupt master is missing. In this case check the card settings. In the dialog box of the link level (see 9.1.1), tab Info, you can see if the communication between ibaFOB card and ibaPADU device is working by checking the baud rate value.
Manual Page 31 Synchronization of Several Boards Shut down the computer, remove the power connection and plug in the other iba PCI cards. Connect the synchronization cable between the devices. This is now necessary because the PCI bus does not support any synchronization signal on the bus which is available at all slots simultaneously.
1,44 A / 5 V (without connected modules) FO-cable 62,5/125 µm Coupling ST Lean Max. distance of fiber optical cable between de- up to 2000 m (6,560 ft) vices (without repeater) Weight (incl. package/documents) 200 g iba AG 2012...
Page 33
90762 Fuerth Germany Phone: +49 911 97282-0 Fax: +49 911 97282-33 Email: iba@iba-ag.com Contact: Mr. Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www.iba-ag.com. iba AG 2012...
Need help?
Do you have a question about the ibaFOB-4i-X and is the answer not in the manual?
Questions and answers