Photoelectric Sensor
Y SERIES
・YT-1180 □
・YR-140 □
・YD-15 □
・YD-L2 □
・YD-L1 □
・YR-Q39 □
・BGS-Y8 □
INSTRUCTION MANUAL
● Confi rm if the item meets your needs.
● B efore the use, you should fi rst thoroughly
read this manual and operate correctly as
mentioned.
● Y ou should keep this manual at hand for proper
use.
Carefully read and understand the safety precautions before operation.
The important information is provided to protect your health and property.
Do not apply any other installing or operating procedure other than that
described in this manual.
● I t is dangerous to wire or attach/remove the
connector with the power on. Make sure to turn off
the power before operation.
● M ake sure to use the product with the protective
cover attached and closed.
● I nstalling in the following places may result in
malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas.
3. A place directly receiving scattering water or oil.
4. A place suff ered from heavy vibration or impact.
●The product is not designed for outdoor use.
● D o not use the sensor in transient state after power
on (approx.100 ms ).
● D o not wire with the high voltage cable or the power
line.
F ailure to do this will cause malfunction by induction
or damage.
● T he sensor performance or digital display values may
depend on the individual units or the condition of
detected product.
●This product is not an explosion-proof construction.
D o not use the product under fl ammable, explosive
gas or liquid environment.
●Do not use the product in water.
●Do not disassemble, repair, or convert the product.
F ailure to do this may cause failure, fi re, or electric
shock.
●Operate within the rated range.
This product cannot be used as a safety device to
protect human body.
Models
Cable type
M8 Connector type
M12 pig tail type
Sensing range
Spot size
Supply Voltage
Current consumption
Response time
Control output
Output
Sensitivity adjustment
Indicator
Ambient Temp./Humidity
Shock resistance
Protection category
Material
Models
Cable type
M8 Connector type
M12 pig tail type
Sensing range
Spot size
Supply Voltage
Power consumption
Response time
Control output
Output
Sensitivity adjustment
Indicator
Ambient Temp./Humidity
Shock resistance
Protection category
Material
※ NPN/PNP diff erent model.
Unit:mm(inch)
Over-current Alarm
indicatar (red)
Over-current Alarm indicatar (red)
Through-beam
Retro refl ective
YT-1180(N,P)
YR-140(N,P)
YT-1180C(N,P)
YR-140C(N,P)
YT-1180(N,P)-M12
YR-140(N,P)-M12
30m
0.05 〜 3.5m (V-61)
Φ 610mm/30m
Φ 75mm/3.5m
10 to 30V DC including 10% of ripple (P-P)
Emitter: 15mA MAX
Receiver: 20mA MAX
NPN or PNP Open collector, 100mA MAX / 30V DC
Incident (Yellow LED) / Over-current Alarm (Red LED) / Stable (Green LED)
※ Emitter of YT type is Power indicator (Green LED) only.
-25 up to 55℃ /35 up to 85%RH
Case: ABS (glass included) Front cover, Lens: PMMA
Retro-Glass
YR-Q39(N,P)
YR-Q39C(N,P)
YR-Q39(N,P)-M12
BGS-Y8(N,P)-M12
0 〜 200mm (sensing distance)
0.15 〜 1m (P45A)
30 〜 200mm (scanning range)
Φ 25mm/1m
10 to 30V DC including 10% of ripple (P-P)
30mA MAX
500 μ s MAX
NPN/PNP Open collector, 100mA MAX/30V DC
Q or Q output
1 turn volume
Incident (Yellow LED) / Over-current Alarm (Red LED)
/ Stable (Green LED)
-25 up to +55℃ /35 up to 85%RH
100G, xyz three directions
IP67
Case: ABS (glass included) Front cover, Lens: PMMA
M8 4pin Model
M12 4pin Model
(-P4,N4)
(-P4,N4)
①・ ・ ・DC10 〜 30V
②・ ・ ・Q output
③・ ・ ・0V
④・ ・ ・Q out put
High transparent object may need adjustment as follows;
Set YR-Q39 face to refelctor without any object, and
slow down the pot till Yellow LED solely lights.
●Type : V-61
Standard for YR-140.
3.5m : YR-140
Convergent
Diff used refl ective
(regular focus)
YD-15(N,P)
YD-L2(N,P)
YD-15C(N,P)
YD-L2C(N,P)
YD-15(N,P)-M12
YD-L2(N,P)-M12
0.4m
43mm
Φ 12mm/0.4m
Φ 4mm/43mm
30mA MAX
500 μ s MAX
Q or Q output
1 turn volume
100G, xyz three directions
IP67
BGS
BGS-Y8(N,P)
BGS-Y8C(N,P)
Φ 15mm/200mm
4 turn (endless)
Tightening torque need to be under 0.5N・m.
Use M3 size screw
M18 nut for front mounting
for side mounting
is packed in the box
●Type : P45A
Standard for YR-Q39.
1m : YR-Q39
Convergent
(close focus)
YD-L1(N,P)
YD-L1C(N,P)
YD-L1(N,P)-M12
16mm
Φ 2mm/16mm
(Unit mm)
Need help?
Do you have a question about the Y Series and is the answer not in the manual?
Questions and answers