2.4 Warnings
Table 2.2 Warnings
Error
Detect low cleaning efficiency
Cleaning interval too intermittent
Time to change Main Filter
HEPA Filter clogged (Hi dp)
Time To Service
Compressed Air Pressure < 5 Bar
PTC fuse Lamp is tripped
Cleaning motor overheated
2.5 Errors
Table 2.3 Errors
Error
Fan Motor overloaded
External Fire detected
V Control transformer overheated.
Overcurrent 10V DC circuits
Overcurrent 24V AC lamp circuits PTC fuse Lamp
tripped
Overcurrent 24V Power DC circuits
24
FilterBox
Solution
Check the cleaning motor (FilterBox A and eQ).
Check the cleaning motor (FilterBox A and eQ).
Change the main filter.
Change the HEPA-filter.
Order service.
• Check the compressed air connection.
• Check that compressed air is 5–8 bar.
• Check maximum voltage for the main light bulb.
(Maximum 20 W)
• Check the connection of the main lighting.
Check that motor and the main filter can rotate
freely.
Solution
• Check that the motor can rotate freely.
• Check the 3-phase connection and fuses.
• Check the external fire alarm.
• Check the transformer voltage.
• Check for a short circuit in the cable.
• Check the transformer voltage.
• Check for a short circuit in the cable.
• Check for short circuits in digital input.
• Check the transformer voltage and maximum
power of the main light bulb. (Maximum 20 W)
• Check for a short circuit in the main lighting.
• Check the transformer voltage.
• Check for a short circuit in the cable.
• Check for short circuits in digital input.