Chirana Medical Smile Mini 04 Instructions For Use Manual

Chirana Medical Smile Mini 04 Instructions For Use Manual

Dental unit
Table of Contents

Advertisement

Dental unit
Smile Mini 04
Instructions for use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smile Mini 04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Chirana Medical Smile Mini 04

  • Page 1 Dental unit Smile Mini 04 Instructions for use...
  • Page 2 Smile Mini 04 INSTRUCTIONS FOR USE DU CHIRANA MEDICAL a.s., STARÁ TURÁ Dr. A. Schweitzera 194, 916 01 Stará Turá, P. O. Box 57, SLOVAK REPUBLIC medical@chirana.eu www.chirana.eu date of the last revision – 04/2019 Serial. No. S14 04100 54...
  • Page 3: Table Of Contents

    Smile Mini 04 INSTRUCTIONS FOR USE DU CONTENTS: Page Operating warnings ......................5 1.1. Symbols ........................5 1.2. Target group ........................ 5 1.3. Service ......................... 5 1.4. Operating book ......................5 1.5. Warranty conditions ....................5 Purpose and use ........................6 Assembly and installation ....................
  • Page 4 15.1. Electromagnetic radiation ..................22 15.2. Resistance against the electromagnetic interference ..........23 15.3. Recommended protective distances between the portable and mobile high frequency communication devices and the dental unit SMILE MINI 04 ......25 Serial. No. S14 04100 54...
  • Page 5: Operating Warnings

    Smile Mini 04 INSTRUCTIONS FOR USE DU Operating warnings 1.1. Symbols By this symbol are marked the attentions in the instructions for use, which require special attention. Before the first using of the product, please be familiar with all of the attentions written in this instructions for use.
  • Page 6: Purpose And Use

    INSTRUCTIONS FOR USE DU Purpose and use The dental unit Smile Mini 04 is intended only for the use in the field of dentisty. The handling of the device can be done only by the qualified medical personnel. The unit is intended for the explosion-proof surrounding.
  • Page 7: Spittoon Block

    Smile Mini 04 INSTRUCTIONS FOR USE DU Dentist table – lower guidance 4.1.1.1. 1. Dentist table 2. Holders of the tools 3. Hoses of the tools 4. Keyboard 5. Rubber tray Dentist table – upper guidance 4.1.1.2. 1. Dentist table 2.
  • Page 8: Foot Actuator

    Smile Mini 04 INSTRUCTIONS FOR USE DU 4.1.2.1. Spittoon bowl The spittoon bowl is rotary. The pipes of the glass and bowl rinsing are detachable. 1. Spittoon bowl 2. Catcher 3. Bowl to the catcher 4. Cover of the sieve 5.
  • Page 9: The Head Of The Light

    Smile Mini 04 INSTRUCTIONS FOR USE DU 4.1.4. The head of the light The headlights are available in four versions: a Halogen light FARO EDI, or LED lights FARO ALYA and FARO MAYA, FARO MAYA and LED A. 4.2. The dimensions of the dental unit...
  • Page 10: The Production Label

    Smile Mini 04 INSTRUCTIONS FOR USE DU 4.3. The production label Producer Year of production The device must not be disposed with Serial Number the household waste CE mark according to Directive 93/42 IPX1C Protection degree / EEC on medical devices with a...
  • Page 11: Basic Equipment

    ATTENTION dental unit - Use only spare parts from CHIRANA Medical inc. Additional equipment Additional equipment delivered with the device is included in the part of the Packing list as an equipment delivered with the device for the special order.
  • Page 12: Operation Of The Product

    Smile Mini 04 INSTRUCTIONS FOR USE DU Operation of the product 8.1. Manipulation with the dentist table The vertical position of the dentist table placed on the pantographic arm is fixed by the brake. By mechanical loading of tray tables it is not given out to the mechanical falling of the table. Before changing of the vertical position of the dentist table is necessary to release the brake.
  • Page 13: Button For The Chair

    Smile Mini 04 INSTRUCTIONS FOR USE DU 8.2.2 Button for the chair The controlling of the chair is the same from the dentist keyboard as well from the multifunctional foot actuator. The chair has its own instructions for use. Safety button STOP By pressing the button is stopped the movement of the chair.
  • Page 14: Multifunctional Syringe

    Smile Mini 04 INSTRUCTIONS FOR USE DU 8.3.1. Multifunctional syringe Pull the syringe from the holder resp. take it up from the seating. For starting the air press the blue button. For starting the water press the green button. For starting of the water nebula press simultaneously blue and green button.
  • Page 15: Ultrasonic Scaler

    Smile Mini 04 INSTRUCTIONS FOR USE DU Revolutions of the micromotor can be adjusted continuously by foot just a foot actuator. Foot switch can only turn on the micromotor revolutions, respectively. switch off. Speed setting can be done using keyboard buttons of the dentist.
  • Page 16: Controlling Tools For The Spittoon Block

    Smile Mini 04 INSTRUCTIONS FOR USE DU 8.4. Controlling tools for the spittoon block 8.4.1. The saliva ejector It is activated by switching the mechanical switch located in the saliva ejector mounted to the position (down) (upwards). To stop the activity switch to position 8.4.2.
  • Page 17: Controlling Of The Assistant Table (Optional Equipment)

    Smile Mini 04 INSTRUCTIONS FOR USE DU Release pressure in the bottle by putting the vent valve to position Breather valve Bottle unscrew by turning of the bottle to the left. When filling bottles make sure that in the bottle are no foreign substances that could affect the composition and quality of clean water.
  • Page 18: The System Of Exhausting And Waste Separation

    Smile Mini 04 INSTRUCTIONS FOR USE DU By blood, sputum exhaustion and by different sanitation resource comes foam, which can cause flooding of the separating CATTANI system and long – time breaking of exhaustion. If you want to avoid the existence of foam insert to the filter of the exhausting hoses (see picture in the Chapter 9.1.) one cleaning and antifoam pill CATTANI and exhaust small amount of...
  • Page 19 Smile Mini 04 INSTRUCTIONS FOR USE DU Dry exhaustion The wet suction Filter of exhausting hoses The filters of suction hoses The filter of spittoon valve Dürr MSBV - Start the cleaning of spittoon valve Dürr MSBV twice a day by pressing the button on the spittoon valve Dürr MSBV (wet suction).
  • Page 20: Maintenance By Service Technician

    Smile Mini 04 INSTRUCTIONS FOR USE DU Chemicals must be collected only on a tray with rubber. When accidental spillage of a substance such. Trikresol, Chlumského solution and other aggressive substances painted parts of the device, the surface must be immediately wiped with swab soaked in water.
  • Page 21: Safety Technical Controls

    Smile Mini 04 INSTRUCTIONS FOR USE DU - Switch ON the dental unit and by the activation of foot control (eventually with the button on the syringe) leak continuously the disinfection agent from each tool hose to the spittoon bowl.
  • Page 22: Storage

    15.1. Electromagnetic radiation The dental unit SMILE MINI 04 is designed for using in the electromagnetic environment described in the following table. The customer or user should ensure that the dental unit SMILE MINI 04 will be operated in the appropriate environment.
  • Page 23: Resistance Against The Electromagnetic Interference

    The dental unit SMILE MINI 04 is designed for using in the electromagnetic environment described in the following two tables. The customer or user should ensure that the dental unit SMILE MINI 04 will be operated in the appropriate environment.
  • Page 24 If the measured field intensity in the site where the dental unit SMILE MINI 04 will be used exceeds the above mentioned complying level, then the dental unit SMILE MINI 04 should be observed to confirm its operation in accordance with the intended purpose.
  • Page 25: Recommended Protective Distances Between The Portable And Mobile High

    SMILE MINI 04 The dental unit SMILE MINI 04 is designed for operation in the electromagnetic environment where is controlled the radiated high frequency interference. The customer or user of the dental unit SMILE...

Table of Contents

Save PDF