Page 1
EclProfile CT+ High quality six colours full spectrum ellipsoidal LED USER MANUAL English version REV.02-07/20...
Page 2
PROLIGHTS product are trademarks OWNED or licensed by Music & Lights S.r.l., its affiliates, and subsidiaries. PROLIGHTS is a registered trademark by Music & Lights S.r.l. All right reserved. Music & Lights – Via Appia km 136,200; Itri 04020, Italy.
• Do not reapply power until repairs have been completed. • Refer any service operation not described in this manual to PROLIGHTS Service team or an authorized PROLIGHTS service center. Installation •...
Page 5
• Warning! Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling. • Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture. • Users may carry out external cleaning, following the warnings and instructions pro- vided, but any service operation not described in this manual must be referred to a qualified service technician.
Page 6
The products to which this manual refers comply with: • 2014/35/EU - Safety of electrical equipment supplied at low voltage (LVD). • 2014/30/EU - Electromagnetic Compatibility (EMC). • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS). PROLIGHTS - EclProfile CT+...
Warning! When clamping the fixture to a truss or other structure at any angle, use clamps of half-cou- pler type. Do not use any type of clamp that does not completely encircle the structure when fastened. Ø13 [Ø0.5] 40 [1.6] 40 [1.6] Fig.2 PROLIGHTS - EclProfile CT+...
• Connect the power connector into the Mains input socket (100-240 VAC-50/60 Hz). • The product is then ready for its operations and can be controlled through the available input sig- nals on board. • To disconnect power from the product, disconnect the Mains from the socket. PROLIGHTS - EclProfile CT+...
12. MAIN FUSE HOLDER: replace a burnt-out fuse by one of the same type only (T5A, 250 V); ); 13. POWER IN: for connection to the Mains 100-240V~/50-60Hz; 14. POWER OUT: power output for connection of multiple units in series. 12 13 14 Fig.3 PROLIGHTS - EclProfile CT+...
... . DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX512 Controller Fig.5 - Example 9 DMX channels configuration PROLIGHTS - EclProfile CT+...
2. Reach the addressing menu, then select the DMX ADDRESS settings. 3. Select the address from 1 to 512 using the navigation arrows/buttons and confirm by pressing ENTER. 4. Press Menu to exit and return to the Home screen. PROLIGHTS - EclProfile CT+...
UP: Browse upwards through the menu list and increases the numeric value displayed. DOWN: Browse downwards through the menu list and decreases the numeric value dis- played. ENTER: Used to confirm the current menu or confirm the current function value or option within a menu. PROLIGHTS - EclProfile CT+...
3400 K 3600 K 3800 K 4000 K 4200 K 4400 K 4600 K 4800 K 5000 K 5200 K 5400 K 5600 K 6000 K 6500 K 7000 K 8000 K 9000 K 10000 K PROLIGHTS - EclProfile CT+...
Page 16
Addr the daisy chain, including or not the With DMX Address dmx address. DMX LOST Blackout Fixture go in blackout if it lose dmx signal. Hold Fixture hold last dmx frame if it lose dmx signal. PROLIGHTS - EclProfile CT+...
Page 17
NOTE: If the projector is in Slave mode if the DMX signal is lost, the projector will remain on according to the last received DMX value. If the projector was in STATIC or AUTO mode, if the DMX signal is lost, the projector will return to the previously set STATIC or AUTO. PROLIGHTS - EclProfile CT+...
189 ÷ 190 0,9 Hz to 20 Hz Random Strobing 191 ÷ 251 Duty Cycle Open Time: 100 ms to 25 ms Duty Cycle Closed Time: 1000 ±500 ms to 25 ±12 ms 252 ÷ 255 Open PROLIGHTS - EclProfile CT+...
Page 21
COLOUR MIX 1 RGB: 255 CMY: 000 Channel Function depending on Set Colour mode 000 ÷ 255 HS: 000 COLOUR MIX 2 RGB: 255 CMY: 000 Channel Function depending on Set Colour mode 000 ÷ 255 HS: 000 PROLIGHTS - EclProfile CT+...
Page 22
Pale Gold 124 ÷ 125 Orange 126 ÷ 127 Deep Straw 128 ÷ 129 Rose Purple 130 ÷ 131 Deep Purple 132 ÷ 133 Soft Green 134 ÷ 135 Reserved 136 ÷ 211 2800K 212 ÷ 213 PROLIGHTS - EclProfile CT+...
13 - ACCESSORIES INSTALLATION OPTIC (CODE ECLPRL) Optics are available as optional accessories. 1. Loosen and remove the two marked knobs. 2. Mount the side desired optic. 3. Insert and tighten the knobs. Fig.8 PROLIGHTS - EclProfile CT+...
1. Push the clip, located at the top of the optics body, outwards and lift it. Then insert the filter into the marked track and close the clip, always applying an outward push. NOTE: To remove the accessory, reverse the procedure. Fig.9 PROLIGHTS - EclProfile CT+...
GOBO HOLDER (CODE ECLPRGH) Gobo holder is available as optional accessory. Gobo dimensions: • Type B • Ø external= 86 mm; • Ø of image= 64.5 mm; • Thinckness= 1.1 mm. 1.1 [0.04] Put in place the Gobo. Fig.10 PROLIGHTS - EclProfile CT+...
Page 29
1. Loosen the marked screws. Then open the slot of the middle part. 2. Insert the gobo holder into the slot. The flaps will go into the appropriate size. NOTE: To remove the accessory, reverse the procedure. Fig.11 PROLIGHTS - EclProfile CT+...
1. Loosen the marked screws. Then open the slot of the middle part. 2. Insert the steel iris diaphram into the slot. The flaps will go into the appropriate size. NOTE: To remove the accessory, reverse the procedure. Fig.12 PROLIGHTS - EclProfile CT+...
Soft edge filter is available as optional accessory. 1. Loosen the marked screws. Then open the slot of the middle part. 2. Insert the Soft edge filter into the slot. NOTE: To remove the accessory, reverse the procedure. Fig.13 PROLIGHTS - EclProfile CT+...
1. Loosen the marked knob and screw. Then rotate the middle part and remove it. 2. Insert the soft focus diffusion kit by placing the magnets (1) on the back of the framing system (2) of the middle part. NOTE: To remove the accessory, reverse the procedure. Fig.14 PROLIGHTS - EclProfile CT+...
Yoke replacement. 1. Loosen and remove the marked screws. 2. Remove the bracket. 3. Mount the Pole Operated Yoke bracket. 4. Tighten the screws. NOTE: To remove the accessory, reverse the procedure. Fig.15 PROLIGHTS - EclProfile CT+...
WARNING: the use of alcohol or any other detergent could damage the lenses. • All other service operations on the product must be carried out by PROLIGHTS, its approved service agents or trained and qualified personnel.
• Check if the Fuse is intact and eventually replace it if fault necessary. • Contact the PROLIGHTS Service or authorized service partner. Do not remove parts and/or covers, or carry out any repairs or service that are not described in...
Page 36
PROLIGHTS is a trademark of prolights.it Via A.Olivetti snc MUSIC & LIGHTS S.r.l. support@prolights.it 04026 - Minturno (LT) ITALY musiclights.it Tel: +39 0771 72190...
Need help?
Do you have a question about the EclProfile CT+ and is the answer not in the manual?
Questions and answers