Stylus Level Setting - Renishaw TS27R Installation And User Manual

Tool setting probe
Hide thumbs Also See for TS27R:
Table of Contents

Advertisement

18
Square stylus
H, L1 and L2
4 mm A/F
4.6 Nm – 5.6 Nm
(3.40 lbf.ft – 4.13 lbf.ft)
Stylus types
Disc stylus
Ø12.7 mm (Ø0.5 in)
Square stylus
19.05 mm × 19.05 mm
(0.75 in × 0.75 in).

Stylus level setting

The top surface of the stylus must be set level,
front to back and side to side.
Stylus level setting
CAUTION: Do not stress the break stem
Disc stylus
L1
Screw with
spring washer
L2
L4
L3
The front to back stylus level is obtained by
alternately adjusting screws L1 and L2, which
causes the probe cable end to rise or lower,
changing the stylus level setting. When a level
stylus surface is obtained, tighten screws L1 and L2.
Side to side level is obtained by alternately
adjusting grubscrews L3 and L4, which causes
the probe module to rotate and change the
stylus level setting. When a level stylus surface is
obtained, tighten screws L3 and L4.
L3 and L4
2.5 mm A/F
0.7 Nm – 0.9 Nm
(0.52 lbf.ft – 0.66 lbf.ft)
Side
Back
Side
Front
H
H