TEMPERATURE CONTROL
Rheem controllers enable the user to control the temperature of the delivered water
from the outlet of the water heater. There are three controllers suitable for installation
with this water heater. They are the Kitchen controller, Bathroom1 controller and
Bathroom2 controller. One, two or three controllers can be installed. A Bathroom2
controller can only be installed if a Bathroom1 controller is installed. Only one of
each type of controller can be connected to the water heater.
The temperature settings of each type of controller are:
Bathroom1 & 2
Kitchen
The installation of Bathroom controller/s only (ie. no Kitchen controller) limits the
outlet temperature of the water heater to a maximum of 50ºC, regardless of the
preset outlet temperature of the water heater. If Rheem controllers are not installed,
the water heater defaults to the preset outlet temperature. Other manufacturers'
controllers cannot be installed with this water heater.
TEMPERATURE ADJUSTMENT
A controller must be on and have priority to be able to adjust the temperature
setting.
The temperature adjustment is made by pressing the up ( ) button or down ( )
button.
The maximum temperature setting for the Kitchen controller is 60
Bathroom controllers is 50
Each press of the up ( ) button will increase the temperature setting by one
increment.
Pressing the up ( ) button continuously will scroll the temperature setting up to
a maximum 43
The temperature setting cannot be increased above 43
flowing.
From the 45
C setting, the up ( ) button must be pressed once for each increase
o
in increment.
The minimum temperature setting for each type of controller is 37
Each press of the down ( ) button will decrease the temperature setting by one
increment.
Pressing the down ( ) button continuously will scroll down the temperature setting.
The temperature setting can be decreased from any temperature setting whether
the hot water is flowing or not.
37
C to 46
C (in 1
o
o
37
C to 46
C (in 1
o
o
C.
o
C if hot water is flowing or 45
o
C increments), 48
o
C increments), 48
o
C if no hot water is flowing.
o
7
C, 50
C.
o
o
C, 50
C, 55
C, 60
o
o
o
C and for the
o
C whilst hot water is
o
C.
o
C.
o
Need help?
Do you have a question about the Integrity 20 and is the answer not in the manual?