Elmes Electronic STM controller is designed for use in
automated window or door roller and shade installations
where 230VAC electric tube motors with end position switch-
es are used.
The controller may be installed inside 60mm deep cable
box of wall switch or inside roller container. Wired control of
the roller is made by two (up/down) pulse operated wall
switches. The roller stops either by reaching end position or,
by passing programmed set on time or, by pressing any con-
trol switch. The controller operates wirelessly with any Elmes
Electronic made hand transmitter comprising of at least two
control buttons. To operate wirelessly a transmitter must be
learned to the STM controller. Most recommended is dedi-
cated STX transmitter with LCD. It features three roller con-
trol type switches for manual control of up to 35 rollers inclu-
sive of up to 8 rollers that can be time pro-
grammed for auto operation. This function is
supported by built in internal real time clock.
Elmes Electronic STM controller can also
operate
DW200H, CH4H, CH4H200, CH8H and
CH23H
transmitters can operate in two wireless con-
trol modes depending on which control but-
ton was used at learning the transmitter to
the STM controller (see fig.1 for buttons lay-
out). One button transmitters cannot be
used.
Mode 1 (recommended) – when button
1 is used at learning transmitter to STM
controller allows roller's upwards movement
when button 1 is pressed, whereas button 3
executes roller's downwards movement. But-
The STM controller pro-
gramming is made using
PRG button with LED status
indication, as shown on side
figure. Led's slow flashing
speed (one per second) in-
dicates correctly performed
procedure.
Fast
flashing
(four per second) indicates
procedures made incorrectly or procedure error. Program-
ming procedures, except for programming motor rotation
timing, are allowed 16 seconds to be completed. After that
time the controller automatically exits programming mode
and indicates programming error.
1. LEARNING TRANSMITTER/S to controller's memory
(up to 112 max):
a) press control unit PRG switch for less than 2 seconds
(LED lights on). Releasing the switch LED continues to
light indicating entering programming mode,
b) press appropriate transmitter button (depending on se-
lected operation mode – see text above) once - LED
switches off. Press the same transmitter button second
time - end of procedure.
2. PROGRAMMING MOTOR ROTATION TIME (from 0,5
second up to 4 hours) – factory programmed time is 40
seconds suitable for most roller applications. To change
the time follow programming steps below:
a) move the roller to down end position,
e-mail: elmes@elmes.pl
MINIATURE WIRELESS CONTROLLER FOR ROLLERS & SHADES AUTOMATION
wirelessly
with
DWB100H,
type
hand
transmitters.
PROGRAMMING PROCEDURES
tons 2 and 4 stop roller movement.
This operation mode is recommended for many rollers
installation controlled by the use of one hand transmitter, as
it allows repeated use of buttons in either direction of roller
movement when, due to low operation range or radio inter-
ference conditions, not all controllers started motor rotation.
This wireless operation mode requires the use of three
or more control buttons transmitters. Two buttons transmit-
ters cannot be used. This mode is also recommended in op-
eration with STX transmitter (with LCD). Learning STX
transmitter to the STM controller "UP" roller movement but-
ton should be used.
Mode 2 – when button 2 is used at learning transmitter
to the controller allows roller's upwards movement and stop
(up-stop-up-stop...) when button 1 of the transmitter is used.
The use of button 2 of the transmitter moves roller down-
wards and stop (down-stop-down-stop...) operation.
This mode is not recommended for use in multi roller in-
stallations. Suitable for operation in this mode are Elmes
Electronic transmitters comprising of two and more buttons.
These
Fig.1. Control buttons layout in Elmes Electronics hand transmitters.
All hand transmitters use KEELOQ® hopping code system.
b) press and hold PRG switch for longer than 2 and shorter
than 8 seconds. Releasing the switch sets the LED off.
c) press hand transmitter's upwards movement button once
– the LED lights and roller start upward movement,
d) when the roller hits end of upward movement position
and its motor is disconnected by internal end of rotation
switch, wait few seconds and press transmitter's up-
wards movement button again – end of procedure.
IMPORTANT: Performing procedure 2 is possible only
with the use of wall switch connected to the controller or
hand transmitter learned to controller's memory.
3. DELETING ALL TRANSMITTERS in controller's memory.
Procedure suitable in case one of transmitters is stolen
or lost:
Press and hold PRG switch (LED lights) in controller un-
til LED starts flashing (over 8 seconds) and release. The
controller memory is now cleared of transmitters, how-
ever programmed motor rotation timing remains un-
changed. To operate the controller by hand transmitter/s
perform learning operation as in clause 1.
4. DELETING ONE TRANSMITTER in controller's memory.
This operation is possible under condition that the
transmitter to be deleted is in our possession.
Start the procedure as in sub-clause 1a) and follow
steps by pressing two different buttons of the transmit-
ter. LED indicating error in this case mean the transmit-
ter is now deleted and will no longer operate the control-
internet: www.elmes.pl