Di-LOG ...measurably better DL107 Operating Manual Contents I. Overview II. Safety Notice III. Instrument Symbols IV. Specification V. Display and Controls 1. Operating Instructions 2. Battery Replacement 3. Warranty Information...
Page 3
Certificate of conformity As the manufacturer of the instrument listed below, we declare under our sole responsibility that the product: Di-LOG DL107 - Voltage Detector to which this declaration relates is in conformity with the relevant clauses of the following standards:...
Di-LOG ...measurably better DL107 Operating Manual I. Overview The DL107 is a non-contact voltage detector with a built-in flashlight and audible/optical alarm function. The CAT IV 1000V safety class ensures user safety, making it an essential tool for the electrical industry.
Page 5
Di-LOG ...measurably better DL107 Operating Manual II. Safety Notices (continued) 6. There may still be voltage even when no audible/optical alarm is on. 7. The insulation type, conductor thickness, distance from voltage source, shielded conductors, other cables, socket design, and other factors may adversely affect test result.
Di-LOG ...measurably better DL107 Operating Manual III. Instrument Symbols Symbols displayed on the instrument and in the instruction manual: Warning! Warns of potential danger, and to comply with the instruction manual. Caution! Dangerous voltage, potential risk of electrical shock. Continuous double or reinforced...
Di-LOG ...measurably better DL107 Operating Manual IV. DL10x Series Specification DL10x Series Voltage Detector Specifi cation DL107 DL108 Low: 24V - 1000V AC Detection voltage range High: 90V - 1000V AC Frequency range 50Hz/60Hz Operation mode Automatic Indication Vibration mode ...
Di-LOG ...measurably better DL107 Operating Manual V. Display and Controls 1. Non-contact voltage sensor 2. LED Flashlight 3. LED for Voltage Indication 4. High/Low mode status indicator light 5. Power button 6. Flashlight On/Off button 7. Pocket clip 8. Battery case cover 1.
Page 9
Di-LOG ...measurably better DL107 Operating Manual AC voltage detection Place the sensor head near the test object or the power socket with AC voltage. When AC voltage is detected, the red LED located within the sensor head will flash and an audible buzzer will sound.
Di-LOG ...measurably better DL107 Operating Manual 2. Battery Replacement 1. Hold the detector with one hand, use the thumb of your other hand to press down on the battery compartment latch, and pull the end of the detector. 2. Pull out the end of the detector in the...
Di-LOG ...measurably better DL107 Operating Manual 3. 24 Month Warranty Di-LOG instruments are subject to strin- gent quality controls. If in the course of normal daily use a fault occurs we provide a 24 month warranty (only valid with proof of purchase).
Need help?
Do you have a question about the DL10 Series DL107 and is the answer not in the manual?
Questions and answers