Siemens SIMATIC MV320 Operating Instructions Manual page 48

Handheld reading systems
Hide thumbs Also See for SIMATIC MV320:
Table of Contents

Advertisement

Technical data
Optical resolution
Roll angle
Angle of inclination
Rotational tolerance
Print contrast resolution
Target beam
Number of scanning operations
Read distances
The read distances are made up of a wide field and a near field.
● All code patterns must be of high quality and on a physical midline at an angle of 10°
when read.
● The table refers to the AGC factory settings; accuracy: ± 10 %
Table 9- 1
Test code
3 mil Code 39
7.5 mil Code 39
10.5 mil GS1 DataBar
13 mil UPC
4.2 mil Data Matrix
5 mil Data Matrix
6.3 mil Data Matrix
10 mil Data Matrix
20.8 mil Data Matrix
1 mil = 0.0254 mm
The ideal read distance is about 100 mm. Depending on the code type and code size,
smaller or larger distances are possible.
48
Near field
Wide field
Read distances
6GF3325-0HT01
960 x 640
960 x 640
±60° (from front to rear)
± 60° level parallel to symbol (from side to side)
± 180°
25% (1D codes) or 35% (2D codes) absolute
dark/light reflectance differential measured at
650 nm
Single, blue target strip
Up to 50 000 scans/charge
Min. mm
80
33
20
28
48
43
33
20
28
Operating Instructions, 08/2015, C79000-G8976-C352-03
Max. mm
102
182
220
280
110
115
150
180
343
SIMATIC MV320 / SIMATIC MV325

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic mv3256gf3320-0ht016gf3325-0ht01

Table of Contents