Field Wiring; Pairing A: Symbio Condenser Or Heat Pump With Constant Volume; Air Handler; Pairing B: Symbio Condenser Or Heat Pump With Szvav / 2-Speed Air - Trane Odyssey TWE0604*A/B Installation, Operation And Maintenance Manual

Split system air conditioners odyssey with symbio controls air handler 5 to 25 tons
Table of Contents

Advertisement

I I n n s s t t a a l l l l a a t t i i o o n n

Field Wiring

Refer to the table below for instructions on field wiring
connections.
Table 7. Field wiring instructions
Condenser
Symbio Condenser
(cooling or heat pump)
Symbio Condenser
(cooling or heat pump)
Symbio Condenser
(cooling or heat pump)
Symbio Condenser
(cooling or heat pump)
Legacy Electromechanical
Condenser
Legacy Electromechanical
Condenser
Legacy ReliaTel
Condenser (cooling or
heat pump)
Note: Gray shaded cells indicate older legacy units.
(a)
Contact the local Trane Commercial Sales office to receive a copy of Hub Case details.
2-Speed Air Handler (identified by a "C" in digit 15) is specifically designed as a replacement air handler for a system with a legacy electromechanical
(b)
condenser.
Pairing A: Symbio Condenser or Heat
Pump with Constant Volume Air Handler
1. Refer to Condenser (SS-SVX001*-EN) or Heat Pump
(SSP-SVX001*-EN) IOM for instructions on
connecting a room thermostat or other zone control
device to the controls of the outdoor unit.
2. 24VAC connection
a. For TWE060 units, transformer TNS3 is
provided and factory wired to supply 24VAC to
the Relay Board.
b. For all other units, 24VAC should be supplied to
the air handler from the outdoor unit as shown
in the schematic (See
3. Thermostat interface
Interconnection wiring as shown in
is required to initiate air handler supply fan
operation and to prevent air handler coil frosting (if
desired).
4. Electric Heat (when installed)
a. IMC (InterModule Communication) wiring is
required as shown in
I I m m p p o o r r t t a a n n t t : : IMC (+, -) signal wiring should be a
twisted pair.
b. For all other wiring associated with electric heat,
refer to Air Handler unit schematic and Electric
30
Condenser
Paired with Air
Model No.

Handler

(Digit 15)
S
Constant Volume
SZVAV / 2-Speed
S
Legacy CV
S
Electromechanical
Legacy 2-Speed
S
Electromechanical
2-Speed
(b)
E
E
Constant Volume
R
Constant Volume
Figure 23, p.
31).
Figure 24, p. 31
Figure 25, p.
31.

Air Handler

Model No.
Field Control Wiring Instructions
(Digit 15)
Pairing A
1
Pairing B
D
182095
0
(a)
182095
(a)
A
Pairing C
C
182095
(a)
1
182095
(a)
1
Heat Accessory Installation Guide (ACC-
SVN91*-EN).
Pairing B: Symbio Condenser or Heat
Pump with SZVAV / 2-Speed Air Handler
1. Refer to Condenser (SS-SVX001*-EN) or Heat Pump
IOM (SSP-SVX001*-EN) for instructions on
connecting a room thermostat or other zone control
device to the controls of the outdoor unit.
2. Connect 24VAC from the outdoor unit to the air
handler as shown in
3. Thermostat interface
Interconnection wiring as shown in
is required to initiate air handler supply fan
operation and to prevent air handler coil frosting (if
desired).
4. Make IMC and MODBUS connections between
outdoor and indoor units as shown on the unit
schematic (see
Figure 25, p. 31
32).
I I m m p p o o r r t t a a n n t t : : Ensure MODBUS and IMC signal wires
(+, -) are twisted pairs.
5. Electric Heat (when installed)
a. The IMC circuit (connected per step 4) controls
stages of electric heat.
b. For all other wiring associated with electric heat,
Figure 23, p.
31.
Figure 24, p. 31
and
Figure 26, p.
SSA-SVX06H-EN