Page 1
SCW53/A (HP201) SCW53/B (HP201) SCW54 (HP201/S) SCW54/A (HP201/S) SCW54/B (HP201S) MADE IN AUSTRALIA SPITWATER AUSTRALIA PTY LTD 953 METRY STREET NORTH ALBURY NSW 2640 AUSTRALIA WARNING: Read and understand this instruction manual before operating this unit and retain for future reference.
Page 2
SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, accessories and service please contact 1800 SPITWATER (1800 774 892) and to view Spitwater's extensive range of high pressure cleaners online visit www.spitwater.com.au...
TECHNICAL DATA MODEL HP201 HP201 HP201/S HP201/S SCW53/A SCW54/A PRODUCT SCW53 SCW54 UNIT SCW53/B SCW54/B PERFORMANCE FLOW RATE PRESSURE PRESSURE NOZZLE WATER INLET PRESSURE MAX TEMP MAX °C ELECTRICAL VOLTAGE PHASE FREQUENCY PLUG CONNECTED LOAD 8.65 8.65 10.72 10.72 RATED CURRENT 12.5...
DESCRIPTION OF SYMBOLS The following symbols are used throughout this instruction booklet in order to mark important paragraphs or sections that require particular attention. Their meaning is listed next to them for your attention. The following symbols are used on the unit, in order to warn user of potential injury if not cautious. Their meaning is listed next to them for your attention.
Page 5
SAFETY LABELS, UNIT COMPONENTS FEATURES & CONTROLS Always pay attention to the safety instructions provided on each label. Do not alter or remove safety labels CHEMICAL TANK TRIGGER PRESSURE LANCE LOW / HIGH HANDLE CHEMICAL LANCE HOLDER FLOW ADJUSTMENT PRESSURE GAUGE WATER INLET PLUG CONNECTOR...
Page 6
GENERAL SAFETY PRECAUTIONS 1. OBSERVE SAFETY INSTRUCTIONS • Make sure you have read and understood the whole instruction manual before installing, operating or carrying out any maintenance on this unit. • Warnings and data plates on the unit provide important directions and information on the safe use of the unit.
5. EXTENSION CORD • If using an extension cord make sure it is according to cross section / maximum length requirements as shown to the right. • Inadequate extension cords can be dangerous. If an extension cord is used, it shall be suitable for outdoor use, and the connection has to be kept dry and off ground.
OPERATIONAL SAFETY PRECAUTIONS All health and safety regulations applicable to general safe work practices, as well as safe operation of equipment, as well as any specific standard for safe operation of high pressure cleaners according to local regulations must be followed. When operating this unit, 1.
Never exceed the maximum working temperature and pressure as indicated on the unit data plate and in this manual. • Only use this unit with cleaning chemicals recommended by Spitwater. The use of other cleaning agents or chemicals may adversely affect the safety of the unit. •...
5. When not in use the unit must be stored in a dry building where there is no possibility for the temperature to be at or below 0°C. If necessary to store the unit at or below 0°C contact your authorized Spitwater service agent for advice.
2. Remove carton and carefully remove the unit from the pallet keeping it upright. Visually check for any damage, leaks or other issues. If any problem is found, contact your Spitwater agent immediately. 3. Identify the unit from the information on the serial label affixed to the unit.
Page 12
• High pressure hoses, fittings and couplings are important for the safety of the machine. Use only high pressure hoses, couplings and fittings recommended by Spitwater. • Do not pull on high pressure hose in order to move the unit.
Contact your Spitwater agent for advice and /or supply. • Make sure the water supply temperature and pressure meet the values specified in the technical data, then turn the water supply on. Visually check for leaks and contact your Spitwater service agent if found. •...
LIST” in the SERVICE / CARE section as a guide. If the unit is damaged or faulty in anyways, DO NOT use it, and immediately contact your authorized Spitwater service agent for advice. TO START 3. Check that the pressure indicated on the 1.
Page 15
4. To adjust spray angle, turn the nozzle head clock USING CLEANING AGENT wise and anti-clock wise as desired. 1. Fill the detergent tank with cleaning solution. Only use a cleaning detergent approved by the manufacturer and do not use under any circumstance acid or corrosive products (contact an authorized service agent or the manufacturer if in doubt).
Page 16
TO STOP 1. Close the chemical injector by turning it clockwise until it stops. 2. Press the unit stop button (I). 3. Disconnect the unit from the power supply. 4. Release all trapped water pressure in the unit by pulling the trigger of the spray gun, then engage the spray gun trigger lock.
2. Carry out all regular maintenance and Spitwater recommends that all maintenance is inspections as listed in this manual using carried out by an authorized Spitwater service original Spitwater parts where required. agent using original Spitwater spare parts. 3. Always make sure before carrying out any...
Check pump seals for any leak. Check proper functioning of STOP button. Assess any undue noise levels from the motor. STOP operting the unit, Unit is fit, proceed task Contact Spitwater service agent immediately Contact Spitwater service Do It Yourself, agent / Qualified person for...
Page 19
USAGE VS SERVICE FREQUENCY TABLE-A: Usage vs Service Frequency Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (e.g. heavy use, dirty water, extreme temperatures or conditions etc.) times should be reduced accordingly.
OIL CHECK POINT PUMP OIL CHECK Ensure the unit is on a flat surface. Check the oil level in the pump using the dipstick or the sight glass on the back / side of the pump. Make sure the level is between min/max level notches on the dipstick, or is level with the indicator on the sight glass...
TROUBLESHOOTING GUIDE If the fault cannot be identified or corrected using the below list (or remedy suggests contacting Spitwater service agent) stop using the unit immediately and contact your authorized Spitwater service agent to rectify. TROUBLESHOOTING GUIDE FAULT CAUSE REMEDY...
Need help?
Do you have a question about the HP201 and is the answer not in the manual?
Questions and answers