Full Disassembly - Nescafe Dolce Gusto KRUPS KP 2106 Service Manual

Beverage center
Table of Contents

Advertisement

Full disassembly

A full disassembly
-
is based on the partial disassembly,
-
is only necessary to repair resp. replace thermoblock, pump with silicone elbow or
power cord with thermo cut off fuses.
A
B
1. Perform partial disassembly first (see page 26).
2. Remove silicone elbow (B) from filter element (A) in housing back bowl (C).
3. Put aside housing back bowl.
D
Line
4. Unplug NTC temperature sensor (E) from electronic main board (D).
5. Unplug 3 flat receptacles (F).
6. For soldered wire (G) on electronic main board:
Unplug flat receptacle from thermoblock.
E
NTC
Heater
Neutral
Pump
G
F
R E P A I R
C