  • Page 1 GSM SMS SECURITY ALARM S120 User Manual Ver 2.0 Date Issued: 2012-08-16...
  • Page 2: Table Of Contents

    3 X1200mAH 120 Seconds Notice: 1. All of the S100,S110,S120 inbuilt 1 Alarm Link relay output, 1 independent relay output for SMS Commands. 2. All of the S100,S110,S120 are provide free charge Android Apps. Please download from our official website.
  • Page 3: Brief Introduction

    SMS Commands from worldwide, no distance limitation. The user can receive SMS Text and incoming from the S120 once the alarm occurrence. Also, the user can remotely switch ON or OFF the electric equipments on-site by SMS Commands. Moreover, the user can call in the S120 to listen in or create two way voice communication with the person on-site.
  • Page 4: Standard Packing List

    A Professional GSM Alarm System designer and manufacturer! GSM SMS Controller Alarm &GSM House Alarm System& GSM Telemetry Units & GSM GPRS Logging System 3. Standard Packing List Control Unit X1 Regulated 12VDC Power Supply X1 Remote Keys X 2...
  • Page 5 Built in 240VAC@3A rated relay output, connect to the device negative electrode. 4.2 Working Principle Drawing The S120 works with wireless detectors or Wired detectors. It can switch on or off one appliance by SMS command and automatically switch on other appliance, equipments for 4 minutes once alarm occurrence. Please see below: 4...
  • Page 6: Features

    GSM Frequency: 850/900/1800/1900Mhz; LCD displays the entire setup menu, user friendly concept to make it easily to setup; Using ICON to display Armed(Away), Partial Armed(At House or Stay), Disarmed, Power status and GSM Signal status; User friendly Icons for LED indicators, Functional Buttons;...
  • Page 7: Settings

    6 tones, if hasn’t been answered, will hang up. If you want to test the two way voice communication, please make sure the other phone is far from the S120, at least 500meters. Otherwise, the near-cross will make lots of noise interference.
  • Page 8 GSM Telemetry Units & GSM GPRS Logging System 6.1.1 Led indicator Description The S120 uses the icons to stand for the function, it is visual and intuitive to users. STAY: Stay Mode indicator, on is in stay mode; ARM: Arm Mode indicator, on is in arm mode, off is in disarm mode;...
  • Page 9 GSM Telemetry Units & GSM GPRS Logging System 6.1.3 Keyboard functions The S120 uses the icons to mark the buttons; it will be more user friendly to user. : Enter button, dial out and answer incoming. : Turn Left Button, Hang up the incoming, Exit, and Backspace button.
  • Page 10 Enter, you can see “Turn on the device” or “Please trigger the new wireless detector”. Then following the instruction to add the new wireless detector to the S120. For Remote control, it will display VVVV if the unit has been assigned remote control.
  • Page 11 Zones’ Attribute definition of the wired zone is the same as the wireless zone. The S120 can accept total 19 wired detectors to 19 wired zones; each zone can be assigned one wired detector, and renamed it by SMS Command. The IN20 is 24 Hours Zone and special for Tamper Switch.
  • Page 12 GSM Operator with different communication protocols. Our system is with the international communications protocols. The Auto-dial Tel. Number can dial to the S120, 6 tones later, can wiretap the system site. Before 6 tones, if somebody answers the calling, then can create two-way voice communication. The other telephone number can call in the S120, if nobody answer 11...
  • Page 13 2 minutes except the SOS help caused. Default is Switch on. If setup the Self-Checking, the system will periodically send “GSM Alarm System in good working condition” to the first SMS Alert number. This is very useful for long time use the system. Default is 0. Means will not report the system condition.
  • Page 14: Operating Instructions

    SMS to the first SMS number. If enable the GSM Jammer Alert function, when the GSM Signal is 0 for more than 90s, the system will drive the siren for 2 minutes and the link-output relay will close 4 minutes.
  • Page 15 A Professional GSM Alarm System designer and manufacturer! GSM SMS Controller Alarm &GSM House Alarm System& GSM Telemetry Units & GSM GPRS Logging System 7.2 SMS Commands for Arm or Disarm or Inquiry system status or switch on/off independent output relay.
  • Page 16: Installation

    Please ensure the wireless detectors and electricity appliances from the mainframe more than 3~5m. 8.1 Insert SIM into Control Unit and install the GSM ANT. In the backside of the control unit, please install the GSM SIM card . The GSM ANT must be Vertical installation to ensure it in good working condition.
  • Page 17 A Professional GSM Alarm System designer and manufacturer! GSM SMS Controller Alarm &GSM House Alarm System& GSM Telemetry Units & GSM GPRS Logging System For a Scrolling Steel Door, a special Wireless Scroll Steel Door magnetic detector must be used due to interference of the wireless signal caused by the steel door.
  • Page 18 A Professional GSM Alarm System designer and manufacturer! GSM SMS Controller Alarm &GSM House Alarm System& GSM Telemetry Units & GSM GPRS Logging System Wireless curtain detector, detection area illustration below: 8.4 Install the Wired Detectors and Electricity equipments Please help to see below wiring diagram, then fixed the related wired detectors, the detectors connect to the related digital inputs.
  • Page 19 A Professional GSM Alarm System designer and manufacturer! GSM SMS Controller Alarm &GSM House Alarm System& GSM Telemetry Units & GSM GPRS Logging System Diagram 2 Diagram 3 8.5 Install the Control Unit In order to avoid destruction of the Control Unit by intruders, please install it in a concealed location, convenient to the operator.
  • Page 20: Add Wireless Detectors

    4 minutes, please contact the siren to the Relay Output 1, the connection please reference Diagram 3. Please note the rated voltage is different for siren and lights. Tips! The Siren should be at least 1.5meters away from the GSM SMS Controller unit, if possible, more than 3meters is better. Siren Strobe Siren 9.
  • Page 21: Technical Specifications

    GSM Telemetry Units & GSM GPRS Logging System 9.3 Add Remote keys to the Control unit: Because of both of the S120 and its remote keys are with learning code, you can add the remote keyto the S120 directly following the 6.2.2.1 Add/Del RF Parts a) Enter the Add/Del RF Parts menu;...
  • Page 22: Maintenance

    GSM SMS Controller Alarm &GSM House Alarm System& GSM Telemetry Units & GSM GPRS Logging System 9) More information will be available of the S120, we will not inform you again after we upgraded, please check with your dealers. 12. Maintenance 1) If the Control Unit works, while the remote key and other detectors fail, please check and change the battery.
  • Page 23 2) Haven’t setup SMS Alert/Auto 3) Please check the commands with CAPS LOCK and correct format. Dial/ dial Numbers. 4) Also, please help to change another GSM Operator SIMCard to test it. No action 3) Caps Lock letters in the SMS after send Commands.