Meaco MeacoFan 1056P Instruction Manual

Meaco MeacoFan 1056P Instruction Manual

Hide thumbs Also See for MeacoFan 1056P:

Advertisement

MeacoFan 1056P Air Circulator
Instruction Manual
MeacoFan 1056P Air Circulator
Please read this instruction manual before using the air circulator and keep safe for
future reference.
Thank you for choosing Meaco, we really appreciate it.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MeacoFan 1056P and is the answer not in the manual?

Questions and answers

Summary of Contents for Meaco MeacoFan 1056P

  • Page 1 MeacoFan 1056P Air Circulator Instruction Manual MeacoFan 1056P Air Circulator Please read this instruction manual before using the air circulator and keep safe for future reference. Thank you for choosing Meaco, we really appreciate it.
  • Page 2: Safety Information

    If these areas become wet for any reason, thoroughly dry them before using the air circulator. If in doubt, do not use the air circulator and consult a qualified electrician or a Meaco approved engineer. The operator must make the operating instruction available for the user and make sure that the user...
  • Page 3: Wiring Instructions

    GREEN/YELLOW. Always ensure that the cord grip is positioned and fastened correctly. Only ever use the same fuse as fitted in the original product, if in doubt please contact Meaco first, or a qualified electrician. Example wiring for a Standard British Plug:...
  • Page 4: General Advice

    GENERAL ADVICE ----------------------------------------------------------------------------------------------------------------------------- ---------- • Before putting your air circulator into operation for the first time, the instruction manual should be studied carefully. • After receiving the air circulator, you should check the unit for any transport damage. In case of damage, you should inform the sender immediately.
  • Page 5 SET UP ----------------------------------------------------------------------------------------------------------------------------- ---------- The MeacoFan 1056P is a pedestal air circulator which can be used at various adjustable heights. In order to adjust the height of the air circulator press the release button on the back of the pedestal.
  • Page 6: Control Panel

    CONTROL PANEL ----------------------------------------------------------------------------------------------------------------------------- ---------- Please note all the buttons are touch sensitive and bleep when pressed. The buttons need to be pressed quickly, do not hold your finger on the button for longer than one second (unless when turning the air circulator ON/OFF, see below).
  • Page 7 ECO Mode Room temperature Fan speed <23°C 23 to 25°C 25 to 27°C 27 to 29°C 29 to 31°C 31 to 33°C >33°C SPEED BUTTON Press the speed button to adjust the air flow fan speed. There are 12 fan speeds available.
  • Page 8: Remote Control

    REMOTE CONTROL ----------------------------------------------------------------------------------------------------------------------------- ---------- POWER BUTTON PRE-ON TIMER PRE- OFF TIMER MODE BUTTON LIGHT BUTTON INCREASE FAN HORIZONTAL SPEED OSCILLATION BUTTON DECREASE FAN VERTICAL SPEED OSCILLATION BUTTON (LOCATING DOT) The following functions are only available via the remote control. All other buttons on the remote-control work in the same way as the control panel (see pages 6 and 7).
  • Page 9: Specifications

    ELECTRICAL CONNECTIONS AND OPERATING CONDITIONS ----------------------------------------------------------------------------------------------------------------------------- ---------- This air circulator was designed to operate in a 220-240V / 50Hz electrical installation. Make sure that the electric sockets are connected to earth and that all safety precautions are taken. This air circulator can be operated within an ambient temperature range from +5°C to +40°C and with a non-condensing relative humidity.
  • Page 10: Cleaning And Maintenance

    CLEANING AND MAINTENANCE ----------------------------------------------------------------------------------------------------------------------------- ---------- Always turn the air circulator off and unplug it from the socket before cleaning. Use a soft dry cloth to clean the external and internal parts of the air circulator. Do not allow the air circulator to get wet.
  • Page 11: Replacing The Remote Control Battery

    REPLACING THE REMOTE-CONTROL BATTERY If the remote control fails to work whilst close to the fan, the battery will need replacing. The battery is a CR2025 and can be replaced following the steps in the diagram below. STORAGE ----------------------------------------------------------------------------------------------------------------------------- ---------- When storing the air circulator use the cable compartment at the back of the air circulator to store the mains cable.
  • Page 12: Troubleshooting

    TROUBLESHOOTING ----------------------------------------------------------------------------------------------------------------------------- ---------- PROBLEM CAUSE SOLUTION The display shows ‘00’ or There is a problem with the Please contact Meaco ‘99’ circuit The air circulator does not The MPCB needs resetting Unplug the air circulator from oscillate the mains for 40 minutes...
  • Page 13: Warranty And Customer Service

    For the full list of the warranty terms and conditions please visit: www.meaco.com/warranty-terms. To prevent unnecessary expenses, we recommend that you always carefully read the user’s manual first. If this does not provide a solution, please call Meaco and we will be happy to help. This air circulator has been imported into...
  • Page 14 This marking indicates that this product should not be disposed with other household wastes throughout the UK and EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.

Table of Contents