INSTALLATION INSTRUCTIONS FOR CENTRAX
CENTRIFUGAL FAN
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
With the use of any electrical appliance, it is important to observe all basic precautions to minimize the risk associated with use, such as
electrical shock, fire, or injury to persons. If this unit is installed in a bathroom or kitchen, power must be supplied from a ground fault
circuit interruptor (GFCI). Read these instructions before using your Centrax ® fan.
NEVER EXPOSE YOUR CENTRAX ® FAN TO TEMPERATURES OVER 140ºF (60ºC)
INSTALLATION
1. Install mounting brackets to fan. (Refer to Figure 1)
2. Secure mounting brackets to a fixed structure. (Refer to Figure 2)
3. Connect the Centrax ® to ventilation system using 6 #6 screws (supplied) when connecting to rigid duct or 2 cable ties (supplied)
when connecting to flex duct.
4. Connect to power source. (Refer to Figure 3)
CAUTION: Before carrying out any maintenance or servicing, ensure the unit is disconnected from the main supply. FOR GENERAL
VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS OR DUST. Use supply
wires suitable for 105°C.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a
tag to the service panel.
c) Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
d) When cutting or drilling into walls or ceilings, avoid damaging electrical wiring and other hidden utilities.
e) Ducted fans must always be vented to the outdoors.
f) If this unit is to be installed over a tub or shower, it must be marked appropriately for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) protected branch circuit.
g) NEVER place a switch where it can be reached from a tub or shower.
h) When used in an attic, install exhaust side of the fan facing an unoccupied space.
i) This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals.
j) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
Model
TF104(-W)
TF106 &
TF108
Model
TF110 & TF112
MOUNTING HARDWARE INCLUDED
#8 x 5/8"
#8 x 1"
Self Tapping
Machine
Screw
Screw
Qty. 4
Qty. 4
Qty. 8
Qty. 8
#10 x 3/4"
#10 x 1"
Self Tapping
Machine
Screw
Screw
Qty. 8
Qty. 8
#6 Screws For Securing Rigid Duct Connection
Qty. 6
Cable Ties For Securing Flex Duct Connection
Qty.2
#6 Lock
Rubber
Hex Nut
Washer
Washer
Qty. 4
Qty. 4
Qty. 4
Qty. 8
Qty. 8
Qty. 8
#10 Lock
Rubber
Hex Nut
Washer
Washer
Qty. 8
Qty. 8
Qty. 8
(Included in all units)
(Included in all units)
Flat
Mounting
Washer
Bracket
Qty. 2
Qty. 4
Flat
Mounting
Washer
Bracket
Qty. 8
Qty. 4
®
Need help?
Do you have a question about the CENTRAX TF104 and is the answer not in the manual?
Questions and answers