saro BC 138 Instruction Manual

saro BC 138 Instruction Manual

Barcoolers with recirculation fan

Advertisement

INSTRUCTION MANUAL
FOR BARCOOLERS WITH RECIRCULATION FAN
Modell BC 138 (437-1020)
Modell BC 208 (437-1025)
Modell BC 330 (437-1030)
BC 138
BC 208
BC 330
English -
translation of the original

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BC 138 and is the answer not in the manual?

Questions and answers

Summary of Contents for saro BC 138

  • Page 1 INSTRUCTION MANUAL FOR BARCOOLERS WITH RECIRCULATION FAN Modell BC 138 (437-1020) Modell BC 208 (437-1025) Modell BC 330 (437-1030) BC 138 BC 208 BC 330 English - translation of the original...
  • Page 2 Dear customer, we congratulate you on your new SARO Barcooler with recirculation fan. Our barcoolers were developed for commercial use and therefore have all the features you would expect from a professional barcooler. The steel housings of the barcoolers are stove-enamelled and therefore insensitive to daily stress. The barcoolers have two height-adjustable shelves per compartment.
  • Page 3: Table Of Contents

    INHALT Introduction ................2 Scope of delivery .
  • Page 4: Introduction

    SCOPE OF DELIVERY • 1 Professional barcooler with recirculation fan • 2 (BC 138) or 4 (BC208) or 6 (BC 330) inlay gratings • 1 Operating instructions STANDARDS AND DIRECTIVES The device complies with current EU standards and directives.
  • Page 5: Model Overview

    MODELL ÜBERSICHT / TECHNISCHE ANGABEN BC 138 BC 208 BC 330 Modell Order No. 437-1020 437-1025 437-1030 Dimensions (mm) W 600 x D 520 x H 850 W 900 x D 520 x H 850 W 1350 x D 520 x H 850 Content (l) Connection (V / Ph.
  • Page 6: Safety Information

    SAFETY INFORMATION • Before the first start-up, read these operating instructions carefully and observe the information given therein. • Incorrect operation and improper handling can lead to malfunctions on the device and injury to the user. • Observe the accident prevention regulations applicable to the area of application and the general safety regulations.
  • Page 7: Safety Information

    SAFETY INFORMATION • In the event of a fault or malfunction, turn off the unit and unplug the power cord. Notify your dealer. He will carry out the repair with original spare parts. • Refrigeration maintenance may only be carried out by qualified personnel. •...
  • Page 8 WARNING: DANGER OF INJURY! • Never try to place your fingers, chopsticks, screwdrivers or other thin objects between the bars of the cold air blower. Behind the protective grille, a fan rotates at high speed. There is a risk of injury, electric shock and damage to or malfunction of the unit.
  • Page 9: General Information

    GENERAL INFORMATION • Before the first start-up, read these operating instructions carefully and observe the information given therein. • Keep these operating instructions within easy reach, near the device. • The manufacturer/dealer cannot be held responsible for damage caused by non-observance of these operating instructions.
  • Page 10: Unpacking

    UNPACKING Make sure that the packaging is undamaged. The device as well as the accessories are protected and / or fixed for transport. After opening the packaging, remove the packaging material and any transport securing devices in the form of adhesive tapes or cable ties. Then check that the delivery is complete and make sure that neither the unit nor the accessories are damaged.
  • Page 11: Affiliation

    After delivery or transport of the device, do not connect it until the device has been idle for at least 24 hours. This is absolutely necessary so that the coolant can collect in the compressor. AFFILIATION Connect the unit only to a grounding socket outlet with an earthing and a 230 volt connection. Before connecting the device, make sure that the voltage and frequency of the power supply correspond to the information on the nameplate! Other voltages can lead to overheating of the device! If you have connected the unit, wait about one hour to allow the interior to cool down...
  • Page 12: Refrigerator Defrosting / Condensation Collector Tray

    OPERATION Um Energie zu sparen und um zu verhindern, dass kalte Luft entweicht, halten Sie die Türen immer nur so lange geöffnet, wie es eben notwendig ist. Dieses Gerät verfügt über einen Umluftventilator, welcher dafür sorgt, dass die kalte Luft im Inneren zirkuliert.
  • Page 13: Maintenance

    MAINTENANCE Maintenance of the Barcooler may only be carried out by qualified personnel! Ensure that the air inlet and outlet openings on the base of the unit are always free of impurities. Check them regularly and remove any dust deposits with the help of a vacuum cleaner.
  • Page 14: In Case Of Malfunctions

    IN CASE OF MALFUNCTIONS In case of malfunctions, please observe and check the following points before requesting service. Barcooler does not cool: Is the power supply interrupted? Has the mains plug been removed from the socket? Has the corresponding fuse tripped? Barcooler does not cool sufficiently: Is the temperature set correctly? Can the cold air circulate freely?
  • Page 15: Disposal

    Your responsible administration will inform you about the addresses and opening hours of collection points. This is the only way to ensure that old appliances are properly disposed of and recycled. Thank you very much! Produced in P.R.C. for SARO Gastro-Products GmbH Sandbahn 6, 46446 Emmerich am Rhein, Germany Tel. +49(0)2822 9258-0 +49(0)2822 18192 E-Mail info@saro.de...