Assembly Instructions Tube Applicator AXON 2 MADE IN GERMANY...
Page 2
Assembly Instruction Edition: 09/2019 - Part No. 9003458 Copyright This documentation as well as translation hereof are property of cab Produkttechnik GmbH & Co. KG. The replication, conversion, duplication or divulgement of the whole manual or parts of it for other intentions than its original intended purpose demand the previous written authorization by cab.
Introduction Instructions Important information and instructions in this documentation are designated as follows: Danger! Draws attention to an exceptionally great, imminent danger to your health or life due to hazardous voltages. Danger! Draws attention to a danger with high risk which, if not avoided, may result in death or serious injury.
Introduction Intended Use • The device is intended exclusively as an option for SQUIX 4MP printers for applying labels onto tubes. Any other use or use going beyond this shall be regarded as improper use. The manufacturer/supplier shall not be liable for damage resulting from unauthorized use;...
Introduction Environment Obsolete devices contain valuable recyclable materials that should be sent for recycling. Send to suitable collection points, separately from residual waste. The modular construction of the device enables it to be easily disas- sembled into its component parts. ...
Mounting Attention! Disconnect the printer from the electrical outlet before mounting or removing the applicator. Removing the Cover Loosen screw (2) and remove cover (1). Replacing the Print Roller Turn the roller bearing (3) with the 2.5 mm Allen key out of the side plate (4).
Mounting Replacing the Dispense Plate Loosen the screw (3) several turns. Slide the original dispense plate (4) upwards and remove it. Place dispense plate of the applicator (1) onto the screw (3) and slide it downwards behind the pins (2). ...
Mounting Insert the pins (5) of the applicator into the holes (3) of the printer. Press the applicator against the printer. That way the plug (7) will be connected to the peripheral port (4) of the printer. Secure the applicator with the screw (6). ...
Settings The applicator can be adjusted as follows: • Adjusting the swing arms (1) to adapt the applicator to the length of the tube and the positioning of the label 3.1 on page 11 • Adjusting the pressure rollers (2) for guiding the cap or thread of the tube ...
Settings Adjusting the Swing Arms The positioning of the swing arms is depending on the following dimensions: • L1 - Length of the tube • B - Width of the label • C - Distance of the label to the upper edge of the tube On the applicator there is a scale (1) to position the swing arms.
Settings Adjusting the Pressure Rollers 2 4 1 5 • Move the pressure roller at the cap side to such a position that the cap (4) will be guided by the swing arm (5) and the pressure roller (2). • Adjust the pressure roller at the other side to the cylindrical zone of the tube (3).
Settings Printer Configuration Note! In that chapter are described the specific applicator parameters of the menu Labelling only. For more information about the configuration Configuration Manual of the printer. Start menu. Select Setup > Labelling. Parameter Meaning Default Peel-off 0.0 mm...
Operation Preparation Press down the locking lever (1) to unlock the applicator. Fold down the applicator. Load labels as shown the figure Instructions of the printer. Load transfer ribbon Instructions of the printer. Fold up the applicator and press it against the printer. The applicator will be locked automatically.
Operation Standard Operation Warning! Risk of injury by rotating parts! During operation, rotating parts are freely accessible. Ensure that people‘s clothing, hair, jewelry etc. do not come into contact with the exposed rotating parts. Send a print job. Insert the first tube. ...
Fault Correction Error message Cause Remedy Device not locked The tube applicator is not Fold up the applicator. in operating position Initialization failed Hardware error tube Switch off and on the system. applicator If error recurs call service. No tube detected No tube in the labelling Insert tube.
In the event of any alteration which has not been approved by us being made to any device as designated below, this statement shall thereby be made invalid. Device: Tube Applicator Type: AXON 2 Applied EU Regulations: Applied Standards: Directive 2006/42/EC on machinery •...
Health. In the event of any alteration which has not been approved by us being made to any device as designated below, this statement shall thereby be made invalid. Device: Tube Applicator Type: AXON 2 Applied EU Regulations: Applied Standards: Directive 2014/30/EU relating to electromagnetic •...