5.1
SELF CHECK FEATURE
5.1.1 OUTLINE
This unit comes with the "SELF CHECK" feature, which checks
the operational state of the circuit and displays/saves it during
failure.Diagnosis is performed when power is turned on, and
information input to the main microcomputer is monitored at all
time.Diagnosis is displayed in 2 ways via screen display and LED
flashes. Failure detection is based on input state of I
the various control lines connected to the main microcomputer.
5.1.2 HOW TO ENTER THE SELF CHECK MODE
Before entering the SELF CHECK mode, confirm that the setting
of TV / CATV SW of the REMOTE CONTROL UNIT is at the "TV"
side and the setting of VCR / DVD SW is at the "VCR" side. If the
switches have not been properly set, you cannot enter the SELF
CHECK mode.
(1) Press the [SLEEP TIMER] key and set it to 30 minutes.
(2) Press the [VIDEO STATUS] key and [DISPLAY] key
simultaneously, then enter the TEST MODE.
(3) Press the [4] key (SELF-CHK) .
5.1.3 HOW TO EXIT THE SELF CHECK MODE
To Save Failure History:
Turn off the power by unplugging the AC power cord plug when
in the SELF CHECK mode.
To Clear (Reset) Failure History:
Turn off the power by pressing the [POWER] key on the remote
control unit when in the SELF CHECK mode.
5.1.4 FAILURE HISTORY
Failure history can be counted up to 9 times for each item.When
the number exceeds 9, display will remain as 9. Failure history
will be stored in the memory unless it has been deleted.
NOTE:
Only SYNC (with/without sync signals) will be neither counted
nor stored.
5.1.5 POINTS TO NOTE WHEN USING THE SELF CHECK
FEATURE
In addition to circuit failures (abnormal operation), the following
cases may also be iagnosed as "Abnormal" and displayed and
counted as "NG".
(1) Temporary defective transmissions across circuits due to
pulse interruptions
(2) Misalignment in the on/off timing of power for I
(VCC) when turning on/off the main power.
Diagnosis may be impeded if a large number of items are
displayed as "NG". As such, start SELF CHECK only after 3
seconds in the case of receivers and 5 seconds in the case of
panels upon turning on the power. If recurrences are expected,
ensure to clear (reset) the failure history and record the new
diagnosis reults.
1-52 (No.YA318)
SECTION 5

TROUBLESHOOTING

2
C bus and
2
C bus
TEST MODE MAIN MENU
TEST MODE
1. I2C STOP
2. STATUS DISP.
4. SELF-CHK
5.CONVER OFF
ROM CORRECTION : ACT
ROM VERSION :
Fig.1
<SELF CHECK>
XRAY
XRAY
NG5
NG5
OCP
OCP
NG2
NG2
LOB
LOB
OK
OK
TIM
TIM
OK
OK
SYNC
SYNC
M:OK
M:OK
S:OK
S:OK
HD:NG
HD:NG
MEM
MEM
OK
OK
AVSW
AVSW
OK
OK
VCD
VCD
OK
OK
AIO
AIO
OK
OK
YC
YC
OK
OK
TUN
TUN
OK
OK
PP
PP
NG 4
NG 4
IP IP
OK
OK
HDMI
HDMI
OK
OK
SPRT
SPRT
OK
OK
Item
Item
Diagnosis
Normal = OK
Abnormal = NG
Fig.2