925 Temperature measuring instrument Bedienungsanleitung Instruction manual Mode d’emploi Content General notes ............22 Safety advice............23 Intended purpose ..........24 Product description ..........25 Display and control elements ........25 Interfaces ..............26 Voltage supply ..............26 Commissioning ..........27 Operation ............28 Connect the probe ............28 Switching the instrument on / off ........28...
Text Display text Text appears on the instrument display. Button Control button Press the button. Result Denotes the result of a previous step. Cross-reference Refers to more extensive or detailed information. Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Ensure correct disposal Take faulty rechargeable batteries/spent batteries to the collection points provided for them. Send the product back to Testo at the end of its useful life. We will ensure that it is disposed of in an environmentally friendly manner.
This chapter gives the areas of application for which the product is intended. Use the product only for those applications for which it was designed. Ask Testo if you are in any doubt. testo 925 is a compact measuring instrument for measuring temperatures.
Select option, increase value (press and hold to increase values rapidly) Print data Change between displaying connected probe and radio probe ( lit) In configuration mode: Select option, decrease value (press and hold to decrease values rapidly) Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
3.2 Interfaces Infrared interface Measurement data can be sent to a Testo printer via the infrared interface on the head of the instrument. Sensor socket(s) Plug-in measuring probes can be connected via the probe socket(s) on the head of the instrument.
To open the radio module compartment on the rear of the instrument, push the clip lock downwards and remove the lid of the radio module compartment. Insert the radio module. To close the radio module compartment, replace the radio module compartment and close it. Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
5.2 Switching the instrument on / off Switching t t he i i nstrument o o n: Press - Measurement view is opened: The current reading is displayed, or ---- lights up if no reading is available. Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Configuration mode is opened, Alarm is displayed. Select the desired option with and confirm with · OFF: Switches the alarm function off. · On: Switches the alarm function on. OFF was selected: Continue with objective O REGISTER THE RADIO PROBE Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Page 10
Select the desired option with and confirm with · YES: Switches automatic probe detection on (recommended). · no: Switches automatic probe detection off. no was selected: to set the probe ID manually and confirm with Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Page 11
10 min. Exception: A recorded reading is shown on the display (Hold or Auto Hold is lit). · OFF: The measuring instrument does not switch itself off automatically. Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Page 12
To s s et t t he d d ate/time: Configuration mode is opened, Year is lit. to set the current year and confirm with to set the other values for the month (Month), day (Day) and time (Time) and confirm each one with Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Page 13
· no: Instrument is not reset. · Yes: Instrument is reset. The instrument is reset to the factory settings. The setting of the probe ID for the radio probe is not reset. - The instrument returns to measurement view. Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Holding t t he r r eading, d d isplaying t t he m m aximum/minimum value: The current reading can be recorded. The maximum and minimum values (since the instrument was last switched on) can be displayed. Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
Page 15
The readings shown on the display (current reading, recorded reading or max./min. reading) can be printed out. A Testo printer is required (accessory part). With the Max./Min. print function switched on, the maximum and minimum values are printed out as well as the current reading or recorded reading.
- The instrument switches itself on and configuration mode is opened. Set the date/time and unit of measurement. See the chapter , objectives ERFORMING SETTINGS and following. ETTING THE DATE TIME Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664 www. .com...
If we are unable to answer your question, please contact your dealer or Testo Customer Service. Contact details can be found on the guarantee card or on the Internet under Testo-Direct sales@GlobalTestSupply.com 1.888.610.7664...
0602 1993 Robust air probe, TC type K 0602 1793 Miscellaneous TopSafe testo 925, protects from impact and dirt particles 0516 0221 Testo printer with IRDA and infrared interface, 1 roll thermal paper and 4 round cell batteries 0554 0547 Radio probes may only be used in countries in which they have been Type Approved (see application information of the radio probe).
Need help?
Do you have a question about the 925 and is the answer not in the manual?
Questions and answers