C6 Is Flashing - Junkers ZWE 24-5 MFA Service Manual

Table of Contents

Advertisement

C6
IS FLASHING
Air pressure switch not closing.
Order
Control Step
1.
Check flue pipe for any blockage or
wrong installation
2.
Check if air pressure switch hoses are
installed correctly?
3.
Check if APS hoses are damaged or
blocked or check if there is
condensation in hoses?
4.
C h e c k the mains supply voltage.
Is it < 230 V?
5.
Check if APS is working or not
6.
Check if the fan is operating or not?
Check if condensation in APS
hose connection points?
6 720 660 238 (2008/07)
Measure
No:
↓ 2.
Yes:
Turn off the appliance
Clean the flue gas pipe or correct the installation
Switch on the appliance
If C6 still flashing ↓ 2.
Yes:
Ø 4.
No:
Turn off the appliance
Correct the assembly of APS hoses
Switch on the appliance
If C6 still flashing ↓ 4
Yes:
Turn off the appliance
Clean and dry APS hoses.
Switch on the appliance
If C6 still flashing ↓ 4.
No:
↓ 5.
Turn off the appliance
Yes:
Change fan
If C6 still flashing ↓ 5.
No:
↓ 5.
Yes:
↓ 6.
No:
Turn off the appliance
Change APS
Switch on the appliance
If C6 still flashing ↓ 6.
Yes:
Turn off the appliance
Clean and dru Aps hose connection points on the
fan
If C6 still flashing ↓ 7.
No:
↓ 7.
Troubleshooting
| 39
39

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZWE 24-5 MFA and is the answer not in the manual?

Questions and answers

מרדכי יורם
March 20, 2025

מה צריך לעשות כשהמכשיר מראה c4

User image 67dc712e4dd21
1 comments:
Mr. Anderson
March 20, 2025

When the Junkers ZWE 24-5 MFA shows error code C4, follow these steps:

1. Check APS hoses: Ensure they are not damaged, blocked, or have condensation.
- If damaged or blocked, turn off the appliance, clean and dry the hoses, then switch it back on.
- If C4 is still flashing, proceed to step 2.

2. Check 20-poled connection cable: Inspect for damage.
- If damaged, change the cable harness and switch on the appliance.
- If C4 is still flashing, proceed to step 3.

3. Check APS functionality: Verify if it is working.
- If APS is not working, further investigation or replacement may be needed.

Following these steps should help diagnose and resolve the C4 error.

This answer is automatically generated

Table of Contents

Save PDF