2-2-2

Mounting of the Connector for Series Connection (Optional)

For constructing the series connection, the following procedure is required.
Do not lose any screws during extension / dismantling work.
Furthermore, do not mix emitters and receivers to mount in series connection
The packing is attached to the connector of the
not attached correctly, reattach the packing as shown in the figure below, and
mount to this device.
<Constructing method for the series connection>
1. Loosen the two M3 screws of the end cap on the main sensor (SF2B-□), and then remove
the end cap from the device.
2. Insert the cable for the series connection (SF2B-CSL□) into the connector of the main
sensor (SF2B-□) and the sub sensor (this device). When inserting the connector, fit the
cable into the groove of the main sensor (SF2B-□) and the sub sensor (this device).
3. Tighten each two M3 screws. The tightening torque should be 0.3N·m or less.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
bottom cap cable.
If the packing is
- 15 -