VEC029AC POWER ™ MULTI-FUNCTION AC/DC JUMPSTART SYSTEM VEHICLE JUMPSTARTER • 200 WATT INVERTER 260 PSI AIR COMPRESSOR • WORKLIGHT/LANTERN OWNER’S MANUAL & WARRANTY INFORMATION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY MANUFACTURER GUIDELINES.
DO NOT clamp directly to positive battery terminal or moving part. • Replace worn or defective parts immediately - contact Vector Technical Support Department at (954) 584-4446. • Skin: if battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap and water.
1. INTRODUCTION ... 1.1 General Discription ... 4 1.2 Key Features ... 5 1.3 Use Power City to ... 5 1.4 Storage Location ... 6 2. USE AS A JUMPSTART SYSTEM ... 2.1 Jumpstart Warnings ... 5 3. USE AS A 12 VOLT DC PORTABLE POWER SUPPLY ... 4.
Power City is also ideal to power 12 volt DC cordless, portable, rechargeable appliances with ratings up to 23 amperes. For information about Vector appliances, contact Vector Customer Sup- port for the location of the nearest retailer.
FIGURE 2 1. NEGATIVE (BLACK) CLAMP 2. AIR COMPRESSOR ON/OFF SWITCH 3. AC RECHARGE PORT 4. POSITIVE (RED) CLAMP 5. AIR COMPRESSOR PRESSURE GAUGE 6. 110 VOLT AC CHARGER KEY FEATURES • ON/OFF safety power switch (no key required, no key to get lost!) •...
STORAGE LOCATIONS Figure 3 shows all removable parts and their locations. Note the location of the storage channels for the jumper cables and compressor hose and nozzle. Two cables are supplied with Power City and they are the Inverter Power Cable with attached Lantern Extension cord and the DC Recharge Cable.
USE AS A 12 VOLT DC PORTABLE POWER SUPPLY WARNING: NEVER INSERT A CIGARETTE LIGHTER IN POWER CITY’S ACCESSORY SOCKET. 1. Lift up the cover of one of the12 volt DC Accessory Sockets. 2. Insert the 12 VOLT DC plug from the appliance into the Accessory Socket. 3.
PRINCIPLES OF OPERATION The Power Inverter converts power in two stages. The first stage is a DC-to-DC conversion process that raises the low voltage DC at the inverter input to 145 volts DC. The second stage is the actual inverter stage that converts the high voltage DC into 110 volts, 60 Hz AC, Modified Sine Wave (MSW).
If the inverter is connected to the incorrect polarity, the fuse will blow. If the unit does not function after replacement of the fuse, the unit must be returned to Vector for repair. Repairs for this type of damage are not covered by warranty.
DO NOT CONNECT TO AC DISTRIBUTION WIRING: the inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner described above. Do not direct wire the power inverter to household or RV ac distribution wiring. Do not connect the power inverter to any AC load circuit in which the neutral conductor is connected to ground (earth) or to the negative of the DC (battery) source.
8. If fuse is good the green LED will light. 9. Check for proper operation by powering a 110 VAC appliance. If there is still a problem, call Vector Technical Support at 954-584-4446. NOTE: If the Main Unit battery is discharged, the Inverter may also be quickly checked by connecting the Inverter Power Cable to the inverter's power pins and plugging the DC Plug into a known to be operating 12 volt DC accessory socket.
TIRE INFLATION OR PRODUCTS WITH A VALVE STEM 1. Place connector (chuck) on valve stem. 2. Push connector toward valve stem and close thumb latch. 3. Make sure connector is pushed on to valve stem as far as possible before closing thumb latch. 4.
LANTERN OPERATION DETATCHED FROM MAIN UNIT The Lantern may be removed for use away from the Main Unit by first sliding the top latch back and then lifting the Lantern as shown in Figure 8. FIGURE 8 LANTERN LATCH A barrel connector near the spring contacts on the back of the Lantern accepts either the AC Recharge or DC Inverter Power Cable’s Lantern Extension cord.
All lead-acid batteries suffer from self-discharge over time and more rapidly when they are at higher temperatures. Therefore, these types of batteries need periodic charging to replace energy lost through self-discharge. When Power City is not in use Vector recommends that the batteries be recharged at least every 60 days.
AC RECHARGE AC Recharge requires the use of the supplied AC/DC Adapter. The adapter must be powered from 110 volt AC, 60 Hz North American standard household AC receptacles. The Battery Status Display will automatically activate during AC recharge. As recharge progresses, the red LEDs will light one by one.
WARNINGS: Other than a fuse in the inverter and a lamp in the lantern, there are no user serviceable parts inside. DO NOT operate unit if there is any evidence of damage. The product must be returned to vector for testing and repair. Replace any damaged cables immediately before further use.
All Vector Manufacturing, Ltd. products are warranted to the original purchaser only for 120 days from the date of purchase, to be free of defects in materials and workmanship. Vector Manufacturing, Ltd. disclaims any liability for consequential damages. In no event will Vec- tor Manufacturing, Ltd.
Page 19
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this warranty. Mail the completed registration form, along with a copy of the original sales receipt, and a check or money order for US$45.00 made payable to Vector Manufacturing, Ltd., to: ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
Need help?
Do you have a question about the Power City VEC029AC and is the answer not in the manual?
Questions and answers