LumaSense technologies IN 5 plus Series Operation Manual

Impac-pyrometer
Table of Contents

Advertisement

Serie IN 5 plus
IMPAC-Pyrometer
Betriebsanleitung · User Manual
Operation Manual · Betriebsanleitung
Proven Quality

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IN 5 plus Series and is the answer not in the manual?

Questions and answers

Summary of Contents for LumaSense technologies IN 5 plus Series

  • Page 1: General

    Serie IN 5 plus IMPAC-Pyrometer Betriebsanleitung · User Manual Operation Manual · Betriebsanleitung Proven Quality...
  • Page 2: Table Of Contents

    IMPAC pyrometers series IN 5 plus Contents General ..............................2 Information about the user manual......................2 Types of instruments ..........................2 Limit of liability and warranty ........................2 Copyright ..............................5 Legend ..............................5 Terminology............................... 5 Disposal / decommissioning........................5 Technical data............................
  • Page 3 IMPAC pyrometers series IN 5 plus Settings via interface / software ......................20 10.1 Connecting the pyrometer to a PC....................20 10.2 Installation ........................... 20 10.3 Program start ..........................21 10.4 The start menu ..........................21 10.5 Beginning ............................ 21 10.6 Number of devices ........................
  • Page 4: Copyright

    IMPAC pyrometers series IN 5 plus Copyright All copyrights reserved. This document may not be copied or published, in part or completely, without the prior written permission of LumaSense Technologies GmbH. Contraventions are liable to prosecution and compensation. All rights reserved. Legend Note: The note symbol indicates tips and useful information in this manual.
  • Page 5 IMPAC pyrometers series IN 5 plus IN 5-L plus T=0...300°C: 0.6% of reading in °C or 2°C (T = 15...30°C) 1% of reading in °C or 3°C (T = 0...15 or 30...63°C) T=300...900°C: 1% of reading in °C (T = 15...30°C) 1.5 % of reading in °C (T = 0…15 or 30…63°C) IN 5/5 plus...
  • Page 6: Dimensions

    IMPAC pyrometers series IN 5 plus IN 5-H plus, IN 5/5-H plus: 0.01 s; adjustable in the pyrometer: 0.5 s; 1 s; 2 s; 5 s, adjustable via interface: 0.5 s; 1 s; 2 s; 5 s; 10 s; 30 s IN 5-L plus: 0.18 s;...
  • Page 7: Overview

    IMPAC pyrometers series IN 5 plus Overview Laser warning label (only instruments with Housing rear panel laser targeting light) Fixing screws for rear panel Stainless steel housing Electrical connector Optics Laser targeting light button Type label (only instruments with laser targeting light) Setting keys at the pyrometer Appropriate use IN 5 plus: The IMPAC pyrometer IN 5 plus is a stationary infrared thermometer for non-contact temperature...
  • Page 8: Safety

    IMPAC pyrometers series IN 5 plus Safety This section offers an overview about important safety aspects. Additionally in the several sections there are concrete safety aspects to avert danger. These aspects are indicated with symbols. Labels and markings at the instrument have to be noticed and keep in a permanent readable condition. General Each person working with the pyrometer must have read and understood the user manual before operation.
  • Page 9: Pin Assignment For The Connector On The Back Of The Pyrometer

    IMPAC pyrometers series IN 5 plus Pin assignment for the connector on the back of the pyrometer Color Indication white + 24 V power supply (18 to 30 V) brown 0 V power supply green analog output output. yellow – I analog output output.
  • Page 10: Connecting To Rs485 Interface

    IMPAC pyrometers series IN 5 plus 4.2.2 Connecting to RS485 interface Half-duplex mode: Terminator 120 Ohm Master A1 and A2 as well as B1 and B2 are bridged in the 12-pin round connector of the connecting cable, to prevent reflections due to long stubs. It also safeguards against the interruption of the RS485 Bus system should a con- necting plug be pulled out.
  • Page 11: Sighting

    IMPAC pyrometers series IN 5 plus Cooling: The completely covered water cooling jacket made from stainless steel protects the pyrometer if exposed to a hot environment. It is designed for ambient temperatures up to 180°C. Water cooling jacket with integrated air purge Miscellaneous: The air purge protects the lens from contamination with dust and moisture.
  • Page 12: Thermal Alignment

    IMPAC pyrometers series IN 5 plus Thermal alignment When measuring a hot object in front of a cooler background, it usually suffices to align the pyrometer to achieve the highest temperature reading. Optics The pyrometers are equipped ex works with one of the following optics. These lenses are focusing to certain distances.
  • Page 13 IMPAC pyrometers series IN 5 plus IN 5/5 plus, IN 5/5-H plus, IN 5/4 plus (each MB 13) Measuring distance a [mm] Optics 100 Spot size M [mm] 1000 Measuring distance a [mm] Optics 300 Spot size M [mm] 4000 Measuring distance a [mm] 2500 1200...
  • Page 14: Instrument Settings

    IMPAC pyrometers series IN 5 plus Note: Please note that the optical profiles show nominal dimensions. The spot size di- ameter or the focal distance may be slightly different due to lens tolerances. Note: The InfraWin program includes a Spot size calculator that roughly estimates the unknown values.
  • Page 15: Instrument Switches

    IMPAC pyrometers series IN 5 plus 8.1.1 Instrument switches 4/0 mA: DIP switch 2 for ad- Emi: Rotary switch for justing the analog output to Emissivity adjustment 0 ... 20 mA or 4 ... 20 mA ONL/OFFL: DIP switch 1 : DIP switches 3,4,5,6 for switching for adjusting the...
  • Page 16: Exposure Time T 90

    IMPAC pyrometers series IN 5 plus Measuring object Emi (at 8 ... 14 µm) Measuring object Emi (at 8 ... 14 µm) "Black body furnace" 100% Brickwork Human skin Fire clay Black dull varnish Rubber Carbon soot Porcelain 85 to 95% Wood 80 to 92% Ceramics...
  • Page 17: Analog Output 0/4 To 20 Ma

    IMPAC pyrometers series IN 5 plus 9.1.3 Analog output 0/4 to 20 mA Settings: When the DIP switch 2 is in the ON position, the analog output will be 4 - 20 mA, in the OFF position, the analog output will be 0 - 20 mA. The analog output has to be selected according to the signal input of the connected instrument (controller, PLC, etc.).
  • Page 18: Subrange

    IMPAC pyrometers series IN 5 plus 9.2.2 Subrange You have the opportunity to choose a subrange (minimum 51°C) within the basic measuring range of the pyrometer. This subrange corresponds to the complete analog output. The lower value (0 or 4 mA) describes the beginning of this measuring range, the upper value (20 mA) the end of the range.
  • Page 19: Wait Time T W (Only Available Via Interface Commands, See 14, Data Format Upp ® )

    IMPAC pyrometers series IN 5 plus ® 9.2.6 Wait time t (only available via interface commands, see 14, Data format UPP Using a pyrometer with RS485 it is possible that the connection is not fast enough to Settings: receive the pyrometer’s answer to an instruction of the master. In this case a wait time 00 Bit can be set to slow down the data transfer (e.g.: tw = 02 at a baud rate 9600 means a 99 Bit...
  • Page 20: Program Start

    IMPAC pyrometers series IN 5 plus 10.3 Program start After installation and the first program start a language must be chosen (German, English, Italian, Spanish. The language also can be changed in the program). On the start page the screen shows the following icons: 10.4 The start menu Opens a saved file...
  • Page 21: Measurement Color Bar

    IMPAC pyrometers series IN 5 plus • When entering a reset time interval other than 0, it must also be determined with “max” or “min” if the maximum or minimum value storage will be activated. • If the pyrometer is equipped with a laser targeting light the laser icon is visible. A click on the laser tar- geting light icon ( ) turns the laser targeting light on or off at this point.
  • Page 22: Measurement Online Trend

    IMPAC pyrometers series IN 5 plus Emi: AutoFind: If the true temperature of the measured object is known, you can calculate the emissivity of the measured object using the "Emi: AutoFind“ function: • A measured temperature is displayed with the current set emissivity (in this example 100%) (here: 824°C).
  • Page 23: Trend Output (Analyzing)

    IMPAC pyrometers series IN 5 plus 10.11 Trend output (analyzing) The graph’s curve depicts the tem- perature change over time within the specified temperature range. Additionally, other information appears in this window; such as recorded time (x-axis) and temperature in degrees (y-axis) as well as the time and temperature at the vertical cur- sor line which can be dragged with the mouse.
  • Page 24: Maintenance

    IMPAC pyrometers series IN 5 plus Maintenance 12.1 Safety Attention during pyrometer services: Should the pyrometer be integrated in a running machine process the machine has to be switched off and secured against restart before servicing the pyrometer. 12.2 Service The pyrometer does not have any parts which require regular service, only the lens has to be kept clean.
  • Page 25: Data Format Upp (Universal Pyrometer Protocol)

    IMPAC pyrometers series IN 5 plus Data format UPP ® (Universal Pyrometer Protocol) Via interface and a suitable communication software or via “Test” function of the InfraWin software (see 10.7 Basic settings Test) commands can be exchanged directly with the pyrometer. Note: The ONL/OFFL switch must be in the ONL position before adjusting the following parameters via the software (see 8.2).
  • Page 26 IMPAC pyrometers series IN 5 plus Error status: AAfs Output 1 Byte hex Bit 0 = 1: EEPROM error Bit 1 = 1: Watch dog Reset Bit 2 = 1: Under voltage reset Reading parameter: AApa Output 11-digit decimal: Digit 1 and 2 (20 to 99 or 00): emissivity Digit 3 (0 to 6): t (exposure time) Digit 4 (0 to 8): t...
  • Page 27: Reference Numbers

    IMPAC pyrometers series IN 5 plus Reference numbers 15.1 Reference numbers instruments Type Optics Temperature range with laser targeting light Interface RS232 RS485 -32 to 900°C (MB 9) 3 869 400 3 869 410 IN 5 plus -32 to 900°C (MB 9) 3 869 420 3 869 430 -32 to 900°C (MB 9)
  • Page 28: Reference Numbers Accessories

    IMPAC pyrometers series IN 5 plus 15.2 Reference numbers accessories 3 820 330 Connection cable, length 5 m (straight connector, 12 pin) 3 820 500 Connection cable, length 10 m (straight connector, 12 pin) 3 820 510 Connection cable, length 15 m (straight connector, 12 pin) 3 820 810 Connection cable, length 20 m (straight connector, 12 pin) 3 820 820...