General nozzle table
Type of gas
Natural gas
G20
Liquefied gas
Butane
Propane
G30/G31
Positioning and levelling
Positioning the appliance
When installing the appliance, make sure that there is enough
space in the final installation location to pull the appliance
forwards for cleaning and maintenance work.
The ground underneath must be hard and firm. The wall
immediately behind the appliance must be made from non-
flammable material, e.g. tiles.
If you need to move the appliance in order to position it, make
sure that the adjustable feet are fully screwed in.
Levelling the appliance
Level the appliance once all other work has been completed.
To do this, turn the adjustable feet.
34
mbar
Nozzle
Number
Bypass
20
115Y
Gap
97Z
Gap
72X
Gap
130k
Gap
150
Gap
105
Gap
28 - 30/37
85
0.42
65
0.31
50
0.27
96
0.60
100
0.55
66
0.65
Type of burner
Output (W)
High output burner
3,000
Standard burner
1750
Economy burner
1000
Wok burner
3600
Oven burner
4300
Grill burner
2000
High output burner
3,000
Standard burner
1750
Economy burner
1000
Wok burner
3600
Oven burner
4300
Grill burner
2000
Consumption max.
286 l/h
167 l/h
95 l/h
343 l/h
410 l/h
191 l/h
219 g/h
128 g/h
73 g/h
262 g/h
313 g/h
146 g/h