INSTALLATION AND OPERATING INSTRUCTIONS
"DESIGNER S" SERIES SAUNA HEATERS
MODELS 4.5S,6.0S,8.0S
(Model #'s 1712-45-0204, 1712-60-0204,1712-80-0204)
(With separate control, -3 designates 3 Phase.)
Read all instructions carefully before installation. Please leave all
instructions and warranty with the owner.
WARNING
Prolonged exposure to elevated temperatures is capable of inducing
hyperthermia. Hyperthermia occurs when the internal temperature of the
body reaches several degrees above the normal body temperature of
98.6°F. The symptoms of hyperthermia include an increase in the normal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The
effects of the hyperthermia include failure to perceive heat, failure to
recognize the need to exit the room, unawareness of impending hazard,
fetal damage in pregnant women, physical inability to exit the room and
unconsciousness.
WARNING
The use of alcohol, drugs, or medication is capable of greatly increasing
the risk of fatal hyperthermia.
SECTION 1: GENERAL INFORMATION
These heaters are ETL approved by Intertek for permanent installations and
electrical connections. Built with splash proof construction, the conducting
parts are protected against water. All wiring must be performed in
accordance with local codes. See Diagram 2 for wire and room size
requirements.
4211-82 01-27-2020
SET TIMER
0
50
10
40
20
30
Sauna Heating
0
SET TEMPERATURE
10
9
1
8
2
7
3
6
4
5
Room Light
TEMPERATURE
CONTROL
MODEL 19-8
U L
Listed
Sauna heater
R
No. 339 B
WARNING
Do not take a sauna if using
alcohol, drugs or medications.
Pregnant women or persons
with poor health should
consult their physician before
using any sauna.
Caution re hazard: Do not use
the sauna room for drying
clothes, bathing suits, etc. Do
not hang towels above heater
or place any object other than
the rocks supplied on the
heater. If any darkening of the
wall around the heater is
noticed discontinue sauna use
immediately.
Inspect sauna regularly for
required maintenance to
heater, control and benches.
Replace wood surfaces which
show any signs of
deterioration.
The heater gets extremely hot
during operation and should
not be touched or burns may
result.
Minors should be adequately
supervised whenever near a
hot or warming sauna.
7014132
314 SKSM 104 P
Page 1
Need help?
Do you have a question about the DESIGNER S Series and is the answer not in the manual?
Questions and answers
On the control panel, the temperature control is not working. I have to turn the knob past the #10 setting on the control panel for the unit to kick on. What do I need to fix, repair, or replace. Having difficulty heating the sauna.
If the temperature control on the Amerec DESIGNER S Series control panel is not working properly and requires turning the knob past the #10 setting for the unit to activate, the thermostat knob or the thermostat itself may need to be fixed, repaired, or replaced. Specifically:
1. Check the Thermostat Knob (Part No: 2140-653) – Ensure it is properly attached and not worn or damaged.
2. Inspect the Thermostat Component – If the knob functions correctly but the temperature setting is inaccurate, the internal thermostat may need adjustment or replacement.
3. Verify Electrical Connections – Loose or faulty wiring could affect temperature regulation.
If replacing, use the specified parts from the heater specification chart.
This answer is automatically generated
Got this unit for my wife--no control panel or heat sensor came with it.
The Amerec DESIGNER S Series heater is intended for use with an SC-9, SC-60, or SC-CLUB control panel. If your unit did not come with a control panel or heat sensor, you should obtain the correct control panel to ensure proper operation. Using any other control panel voids the warranty and UL listing. Additionally, the unit requires a heat sensor for proper function. You may need to contact the manufacturer or a service provider to acquire the necessary components.
This answer is automatically generated
Hello, I **** trying to upgrade from the SC-60 controller to the digital Saunalogic2 60 minute digital controller. Is the Saunalogic2 digital controller compatible with this model Saunatec 1712-80-0204 Sauna model? Note: We have the Control Box (CB16) needed for new digital controller and have installed everything properly but we get a permanent (HL) High Limit error when we turn components on.
My sc60 control panel timer does not shut off after 60 min, what could be issue?
If the timer on the Amerec DESIGNER S Series SC60 control panel does not shut off after 60 minutes, the issue could be a malfunction in the 60-minute timer component (Part No. 3140-505). It may need to be inspected or replaced.
This answer is automatically generated