ENGLISH DWPS102S DWPS102A DWPS102U DWPD102SXX DWPD102AXX DWPD102UXX DIGIWAY plus Single or double door, inward and outward, automation door The installer’s choice INSTALLATION, USE AND MAINTENANCE MANUAL...
INSTALLATION MANUAL DIGIWAY PLUS Summary page General safety precautions..........................2 Machinery Directive ............................3 Instructions of use .............................. 3 Declaration of the Manufacturer ......................... 3 Identifying product and parts ..........................4 Accessories ............................... 5 Overall dimensions and mounting guide ......................6 Technical specifications ............................
Page 3
INSTALLATION MANUAL DIGIWAY PLUS Important precautIonS for the Safety The present document contains important precautions for the use and the operating safety. Read carefully the instructions before commencing the installation Keep this document even after installation. This manual is intended for professional installers, adequately trained.
INSTALLATION MANUAL DIGIWAY PLUS Important precautIonS for the Safety ( follows) Only use genuine spare parts if replacements or repairs are required. The motor manufacturer declines any responsability in the event of component parts fitted that are not compatible with the safe and correct operation. The actuator must be installed only inside buildings The manufacturer declines all liability for damage caused by assembly on the outside, without adequate protection.
Applications : HEAVY DUTY, for pedestrian accesses to institutional complexes with very intense use. Declaration of the manufacturer ( according to Directive 2006/42/CE, Annex II part B ) The Manufacturer CDVI WIRELESS SPA - CDVI Group Via Piave,23 31020 S.Pietro di Feletto (TV) ITALY...
INSTALLATION MANUAL DIGIWAY PLUS Identifying the product and its parts Digiway type DWPx102xx is a indoor operator for swing doors, with integrated electronic controller and radio receiver. The opening and closing motion is electromechanical with backup battery which assures the operation in cases of power failure.
INSTALLATION MANUAL DIGIWAY PLUS accessories Description F-code Kit articulated arm DWKBA F0543000030 Kit sliding arm DWKBS F0543000031 Kit universal arm DWKBU F0543000122 Extension 55 mm DWSE F0543000033 Extension 30 mm DWSE30 F0543000123 Extension 80 mm DWSE80 F0543000136 Double door cable...
INSTALLATION MANUAL DIGIWAY PLUS mounting diagram Cover lift point Screws for plugs SX8 Plugs SX8 M6x14 M6x14 Washer M6x14 accessories Sliding arm Screw M6x14 provided articulated arm Screw M6x14 provided universal arm The Universal arm kit allows to realize both the arms. The kit is composed by a complete sliding arm, with the guide and by an adjustable forearm with the door bracket.
Digiway plus does not need a door-stop fitted to complete the open cycle. Make sure any closing device is completely removed including hydraulic devices, turn to free or minimum is not sufficient.
INSTALLATION MANUAL DIGIWAY PLUS articulated arm version This part is addressed to outward door installations Identify the dimensions of the motor, locate the fixing position, the holes for the cables and the 6 fixing holes making use of the mounting template provided;...
Page 12
INSTALLATION MANUAL DIGIWAY PLUS Wiring diagram 6 x 0.8 mm ftc-S [ Stop ] 6 x 0.8 mm ftc [ re-open ] Internal external radar radar Connect the equipment to the Mains power using the appropriate cable ( 3 x 1,5mm ), passing it through the rear opening of the profile and the backplate and avoiding being too tense and touching sharp edges.
INSTALLATION MANUAL DIGIWAY PLUS electrical connections to the motor fuSe 5a from toroidal transformer to toroidal transformer 230 Vac electrolock Supply ftc-S (*) ftc (*) external magnet supply magnet (*) See next page for the connection connections detail 19-way terminal block...
If devices type ESPE ( photocells ) are used, they must be monitored by the drive system. Digiway Plus is equipped with output test signals ( Test1, C, Test2 ) that check the photocells status before any motion. The system switches off for few mS the photocell through the test signal and checks the changement of the signals on the terminals 5-6 or 6-7.
GettInG StarteD Digiway Plus is equipped with a 2x16 characters LCD Display and by a 5-keys keyboard. The operating configuration can be set navigating through several menus. The menu has a tree structure with a main menu and different sub-menus.
INSTALLATION MANUAL DIGIWAY PLUS Guided configuration The operator is supplied with a 4-button transmitter included. On completion of the mechanical fixing and the electric connections, proceed with the memorization of the transmitter into the internal memory inside Digiway. This transmitter can then set-up of all parameters, without accessing the 5 buttons onboard.
INSTALLATION MANUAL DIGIWAY PLUS STEP II: CONFIGURATION Step II allows you to set all the basic parameters of the operator, according to the type of door to automate The submenu CONFIGURATION consists of 18 parameters. Each parameter can have 2 or more values.
STEP III: DOOR CALIBRATION [ SINGLE LEAF ] DIGIWAY PLUS is equipped with an innovative software which fits the internal parameters to the door characteristics. The calibration sets the door travel limits and launches a special 5 cycles routine for the automatic detection of the door characteristics.
INSTALLATION MANUAL DIGIWAY PLUS STEP IV : ADJUSTMENTS CURRENT CALCULATION CYCLES At the end of the door calibration, the door will operate normally. However, to complete the calibration the system needs 2 more complete cycles to calculate the 2 currents ( called “i” and “I”) necessary for obstacle management.
STEP V: ADVANCED SETTINGS DIGIWAY PLUS is equipped with many further parameters (all adjustable) to fit better to any type of installation. From the main menu select ADVANCED SET to enter this submenu, which allows more adjustments.
Page 21
INSTALLATION MANUAL DIGIWAY PLUS STEP V: ADVANCED SETTINGS (Continued...) The dynamic pause is a function which automatically adjusts the pause time Advanced Setting Enable / Disable Dynamic Pause programmed, avoiding too many closing attempts of the door in high traffic situations.
Page 22
INSTALLATION MANUAL DIGIWAY PLUS After the detection of an obstacle during the closing the door will react in different way, Advanced Setting OD on Closing OD on Closing Reopen according to the following settings: • Reopen : The door reopens and after the pause time recloses •...
INSTALLATION MANUAL DIGIWAY PLUS Disabled persons access settings If the operator is used for disabled persons access, adjust the opening and closing speed of the leaf for Low Energy setting Door weight Door lenght 50 Kg 60 Kg 70 Kg...
INSTALLATION MANUAL DIGIWAY PLUS menu Service The unit is equipped with 2 cycle counters : Absolute Counter and Partial Counter The Absolute Counter registers the cycles of the motor for all its life : It cannot be reset except by the factory.
INSTALLATION MANUAL DIGIWAY PLUS Information It’s possible to change the information displayed on the LCD by setting the operating Information Display Display Expert / Normal mode EXPERT or NORMAL In EXPERT Mode all the main parameters of the motion will be displayed according to...
INSTALLATION MANUAL DIGIWAY PLUS Double door configuration The double door configuration applies to both the types DWPD102X and DWPS102X. For the types DWPD, for which a central profile is provided, it is necessary to install a back plate which ensures perfect alignment between the profiles and 2 lateral back plates in place of the regular single door back plate.
Page 27
INSTALLATION MANUAL DIGIWAY PLUS 3. Motor fixing Fix each motor with the 6 screws M6x14 provided. 6 x M6x14 screws for fixing to the back-plate Left Motor Right Motor 4. Door guides fixing ( inward opening ) • Fix the 2 arms on the motor shafts with the screws M6x12 provided;...
Page 28
INSTALLATION MANUAL DIGIWAY PLUS part II: electrical connections The range of motors for the double door is described in the following table: Double door total width Leaves width p/n Articulated Arm p/n Sliding Arm p/n Universal Arm 1600 mm 70 - 80 mm...
Page 29
INSTALLATION MANUAL DIGIWAY PLUS part III : final set-up Follow the set-up procedure hereunder both 2 x single motors ( DWPSxx ) and for a double door unit ( DWPDxx). This can be completed only if the mechanical and electrical installations have been executed.
DIGIWAY PLUS maintenance An automatic door, realized through the installation of the operator DIGIWAY PLUS, needs periodic checks ( at least every 12 months ) as listed in the following points: 1) Check the door balancing and the perfect functionality of the hinges;...
INSTALLATION MANUAL DIGIWAY PLUS use Instructions If the door is working properly the led Lp is StaBLe Green HOW TO OPEN THE DOOR According to the peripherals installed the door driven by this operator can be opened by the following devices: •...
Page 32
INSTALLATION MANUAL DIGIWAY PLUS NOTE Manufactured by CDVI Wireless S.p.A. Via Piave, 23 31020 S.Pietro di Feletto (TV) ITALY...
Page 33
INSTALLATION MANUAL DIGIWAY PLUS Installing manufacturer: (Name of the company who installed the Automatic Door Operator) Identification: (Identity of the door that has been automated such as door location or serial number) Site (Details of the building where the door operator has been installed)
Page 34
INSTALLATION MANUAL DIGIWAY PLUS Hazard Description Installation notes and/or actions taken to eliminate or reduce the risk Impact Crushing Shearing Wedging Conveying Cutting Hooking Service Date: Operator name: Description Maintenance Repair Upgrading Other Signature Date: Operator name: Description Maintenance Repair...