Choose Your Complaint: Leaking Pump Performance Clutch Operation Agitation Issues Other Hydroseeder Practical Service Guide for the Parts Professional ...
Page 3
What is Leaking? Choose an area: o Agitator Bearing/Shaft o Suction or Discharge Piping/Joints o Pump o Hydraulic Components Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 4
Suction or Discharge Piping/Joints Choose an area: o Leaking at clamp joints o Leaking at nozzle connections o Leaking from Swivel Joints Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 5
Pump Leaking Choose an area : o Leaking around Pump Shaft o Leaking water around Pump Suction Cover Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 6
Pump Performance Choose an issue: o Pump Vibrating o Lack of distance or low pressure all the time o Lack of distance or low pressure‐ starts okay gets steadily worse o Sprays then stops quickly o Pump not working at all Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 7
Clutch Operation Choose an issue: o Clutch will not engage o Clutch is hard to engage‐ Not applicable on Kohler powered equipment o Clutch is too easy to engage‐ Not applicable on Kohler Powered equipment o Clutch jumps out once engaged‐ Not applicable on Kohler Powered equipment Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 8
Agitation Issues Choose a complaint: o Agitator will not turn on o Agitator makes machine Jump when running o Leaking around Agitator shaft o Agitator making banging noise o Agitator motor moving Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 9
Agitator Bearing/Shaft Leaking 1. Check the tightness of the bolts‐ tighten uniformly to 25 ft. lbs. 2. Seal is worn‐ Replace the bearing and seal Kit choose machine below to access part Breakdown. o T30 o T60 o T75 o T90/T120 o T170/T280/T330 Serial Numbers BN, BU, BB, BR, RS, RM, RO, RD, RE, RL, RN, RU o T170/T280/T330/T400 Serial Numbers‐ All other serial numbers o Titan Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 10
Clamp Joints Leaking Rubber seals are cracked, pinched or torn and need replaced. Be sure to grease the seals before clamping shut. Back to Complaint Screen ...
Page 11
Nozzle Connections Leaking Rubber O‐ring inside of the female connector is worn or missing. Replace the gasket‐ making sure to grease before installing. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 12
Swivel Joints Leaking Is the joint leaking and wobbling in all four directions? The swivel has to be replaced. Choose your machine below. Is the joint leaking and still feels fairly stable? The swivel can be rebuilt. Choose your machine below. o T60 o T75 o T90/T120 o T170 o T280/T330/T400 o Titan Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 13
Leaking around Pump Suction Cover Pump Maintenance should only be performed with engine off and battery cables disconnected. 1. Replace Suction cover O‐ring‐ be sure to grease o‐ring before installing. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 14
Leaking water around Pump Shaft Pump Maintenance should only be performed with engine off and battery cables disconnected. 1. Replace mechanical seal in the pump. Be sure to fill the pressure lubricator daily with Finn Pump Grease. *Note: Customer may want to replace all the seals and bearings in the pump while they are taking it apart. Be sure to suggest the labor savings in doing it all at one time. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 15
Hydraulic Fluid Leaking 1. Determine which component is leaking‐ motor, pump valves etc. Call Finn Parts Department to determine if a seal kit is available or if part must be replaced. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 16
Pump Vibrating Pump Maintenance should only be performed with engine off and battery cables disconnected. 1. Check for material Packed around the impeller‐ clean area of any debris. 2. Feel the bearing area on the casing. Is it warm or the source of the vibration? If so replace pump seals and bearings. 3. If machine has a coupling insert between the pump and the clutch‐ inspect for missing teeth or alignment issues. If missing teeth replace insert. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 17
Lack of distance or low pressure all the time 1. Check impeller tolerance. It should be .030”‐.040”. Click here to access adjustment instructions. 2. Check the nozzle opening for wear and/or blockage. Clean and replace if necessary. 3. If machine is belt drive‐ check the belt tension and adjust if needed. 4. See Clutch Adjusting instructions‐ Click here to access. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 18
Lack of distance or low pressure‐ starts okay gets steadily worse 1. Are you spraying a new material? Slow the agitator to ½ speed and close the recirculation valve. 2. Is it cold outside? Slow the agitator to ½ speed and close the recirculation valve. 3. If machine is belt drive‐ check the belt tension and adjust if needed. 4. See Clutch Adjusting instructions‐ Click here to access. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 19
Sprays then stops quickly 1. Check for clogs in nozzle, suction or discharge piping. Back flush unit with air or trash pump to clear lines. If this does not rectify‐ unit may need to be disassembled and cleaned to resolve issue. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 20
Pump not working at all 1. Is the pump turning when engaged? Yes or No **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 21
Pump Turning when Engaged Pump Maintenance should only be performed with engine off and battery cables disconnected. 1. Check for clogs in suction or discharge piping. Back flush unit with air or trash pump to clear lines. If this does not rectify‐ unit may need to be disassembled and cleaned to resolve issue. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 22
Pump Not Turning when Engaged 1. Is the clutch engaging? Watch for the shaft to turn‐ Yes or No **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 23
Clutch Engaging Pump or Clutch Maintenance should only be performed with engine off and battery cables disconnected. 1. Check components between pump and clutch‐ Coupling, belt etc. 2. If it is cold outside make sure that pump is not frozen. 3. Check to see if pump is jammed with fertilizer or lime‐ remove suction cover and remove debris. 4. Check to see if impeller is rusted to suction cover‐ pull cover and remove any rust. **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 24
Clutch Not Engaging 1. See Clutch Adjusting instructions‐ Click here to access Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 25
Clutch will not engage 1. Please choose your machine: o T30 o T60 o T75 o T90/T120 o T170 o T280/T330/T400 Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 26
Clutch will not engage‐ Electric Clutch 1. Check for 12V power when switching on. 2. If you have power‐ it is the clutch that needs replaced. There is no adjustment on this clutch. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 27
Clutch will not engage‐ Mechanical Clutch 1. Clutch needs adjustment. See Clutch Adjusting instructions‐ Click here to access. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 28
Clutch is hard to engage‐ Mechanical Clutch 1. Clutch needs loosened. See Clutch Adjusting instructions‐ Click here to access Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 29
Clutch is too easy to engage‐ Mechanical Clutch 1. Clutch needs tightened. See Clutch Adjusting instructions‐ Click here to access Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 30
Clutch Jumps out once engaged‐ Mechanical Clutch 1. Clutch needs tightened. See Clutch Adjusting instructions‐ Click here to access Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 31
Agitator will not turn on 1. Check Hydraulic Oil‐ Add oil if necessary. 2. Check the agitator control cable for functionality. Adjust if necessary. 3. Check Hydraulic Oil Pressure‐ With the agitator off‐ jam the agitator with a long board. Then start the agitator. Check the hydraulic pressure gauge for the stalled pressure. T30‐ 1750 PSI T60‐ 2250 PSI T75‐ 2300 PSI T90/T120‐ 2100 PSI T170‐ 2650 PSI T280/T330/T400‐ 3000 PSI Click the appropriate result: o Pressure is low; o Pressure Spikes & Falls o Pressure is nonexistent Back to Complaint Screen o Pressure is correct Hydroseeder Practical Service Guide for the Parts Professional ...
Page 32
Agitator makes machine Jump when running 1. Check agitator for bent paddles. Straighten or replace paddle and realign agitator. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 33
Leaking around Agitator shaft 1. Click here to jump to leaking complaint. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 34
Agitator making banging noise 1. Check the torque arrestors on the agitator motor for wear. If the are torn or worn‐ replace. 2. Check agitator for movement in one direction‐ paddles may be hitting the tank‐ If so‐ realign agitator and check set screws on the bearings. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 35
Agitator motor moving 1. Check the coupling between the motor and the shaft for tightness or wear. Tighten or replace. 2. Check the alignment the agitator shafts‐ shim or replace if necessary. 3. If coupling and the shaft check okay‐ as long as torque arrestors do not compress completely some movement is acceptable. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 36
Agitator Hydraulic Pressure is low 1. Adjust the pressure by turning the relief cartridge clockwise. Using small increments until desired pressure is reached. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 37
Agitator Hydraulic Pressure Spikes and then falls 1. This is a sign of a failing hydraulic pump. Replace hydraulic pump. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 38
Agitator Hydraulic Pressure is nonexistent 1. This is a sign of a failing hydraulic pump. Replace hydraulic pump. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 39
Agitator Hydraulic Pressure is correct 1. This is a sign of a failed hydraulic motor. Replace the Hydraulic motor. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 40
Other 1. Customer lost nozzles‐ Refer to nozzle manual available online. 2. Customer needs part breakdown or wiring diagram‐ Refer to parts manuals available online. 3. For other complaints‐ Please call Finn Parts or Service 1‐800‐229‐8707 or 1‐800‐543‐7166. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 41
T30 1‐1/2” Bearing & Seal Kit‐ 085161‐01 and 085161‐02 Bearing and Seal Assembly Back to Complaint Screen ...
Page 42
1‐1/2” Bearing and Seal Kit‐ 007420 Bearing and Seal Assembly Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 43
2” Bearing and Seal Kit‐ 012529 Bearing and Seal Assembly (Includes items 2‐9) Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 44
T60 Discharge Boom & Swivel 8 003207 Replacement 1‐1/2” Swivel Joint 1 003355 Swivel Repair Kit‐ Includes ball bearings and seals 1 Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 45
T75/T90/T120 Discharge Boom & Swivel 8 007288 Replacement 2” Swivel Joint 1 006969 Swivel Repair Kit‐ Includes the ball bearings and seals 2 Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 46
T170/T280/T330/T400 Discharge Boom & Swivels 3 012283 Replacement 2‐1/2” Straight Swivel 2 012397 Swivel Repair Kit‐ includes ball bearings and seals 1 per Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 47
Titan Discharge Boom & Swivels 5 012888 Replacement 3” Straight Swivel 2 013043 Swivel Repair Kit‐ Includes ball bearings & Seals 1 per Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 48
Pump Adjustment Instructions Pump Maintenance should only be performed with engine off and battery cables disconnected. 1. Loosen the bolts with the jam nuts so they are out of the way. 2. Tighten the bolts with the flat washer until the suction cover touches the impeller. If the cover bottoms out before touching the impeller‐ one or both pieces may need replaced and should be inspected. 3. Tighten the bolts with the jam nut by hand until the touch the housing. 4. Loosen the bolts with the flat washer a couple of turns. 5. Loosen the bolts with the jam nut 1‐1/2 turns. Lock the jam nuts down. 6. Tighten the bolts with the flat washers. Do not exceed 15 ft lbs and follow accepted torque procedures. 7. Turn the pump by hand through one full revolution checking to make sure it turns free. Back to Complaint Screen **Note: The pump impeller does have regular threads. Please be sure to mention this to any customer getting ready to disassemble a pump! Hydroseeder Practical Service Guide for the Parts Professional ...
Page 49
Clutch Adjusting Instructions There are two different types of mechanical clutches on Finn Machines. To identify, remove the inspection cover and count the number of “Fingers” on the clutch. Choose the appropriate clutch below: 3 “Fingers” 4 “Fingers” Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 50
NACD Clutch Adjustment Clutch Maintenance should only be performed with engine off and battery cables disconnected. The clutch has a castle ring that is held in place with a retaining clip. To adjust, remove the retaining clip, being careful not to drop the clip into the housing. To Tighten‐Turn the castle ring counter clockwise a few teeth and use the handle to test the correct feel‐ continue adjusting until handle has a firm snap. Once adjusted reinstall the retaining clip. To loosen adjustment turn ring clockwise. *Note: Machines with air operated clutches will have to have the air cylinder disconnected to properly adjust the clutch. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...
Page 51
Twin Disc Clutch Adjustment Instructions Clutch Maintenance should only be performed with engine off and battery cables disconnected. The clutch has a locking pin toward the center of the clutch. To tighten, pull the pin out with needle nose pliers. Turn the ring clockwise a few teeth to tighten and use the handle to test for correct feel‐ continue adjusting until handle has a firm snap. To loosen the adjustment‐ turn the ring counter clockwise. Note: Machines with air operated clutches will have to have the air cylinder disconnected to properly adjust the clutch. Back to Complaint Screen Hydroseeder Practical Service Guide for the Parts Professional ...