SystemAir Fantech DEDPV-705 Installation And Operation Manual

SystemAir Fantech DEDPV-705 Installation And Operation Manual

Dryer exhaust duct power ventilator

Advertisement

DEDPV-705
Dryer Exhaust Duct Power Ventilator (DEDPV)
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS IMPOTANTES POUR LA SÉCURITÉ
SAVE THESE INSTRUCTIONS
CONSERVEZ CES INSTRUCTIONS
DEDPV-705 KIT INCLUDES:
Inline Fan with Integral Control, 1 pc
2 ft Section of Tubing, 2 pcs
FC4 Clamps, 4 pcs
Grommet for Tubing, 1 pc
Mounting Bracket and Hardware, 1 pc
Indicator Panel, 1 pc
4" x 4" Indicator Cover Plate, 1 pc
50 ft (15.4 m) Communication Cable, 1 pc
Warning Label for Indicator Cover Plate, 1 pc
REGISTER* THIS PRODUCT TO
INCREASE YOUR PRODUCT
WARRANTY BY AN EXTRA YEAR
registration.fantech.app
Technical / Customer Support
United States: 800.747.1762
Installation and Operation Manual
* in USA only
Item #: 483443
Rev Date: 6/10/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fantech DEDPV-705 and is the answer not in the manual?

Questions and answers

Summary of Contents for SystemAir Fantech DEDPV-705

  • Page 1 Item #: 483443 Rev Date: 6/10/2020 Installation and Operation Manual DEDPV-705 Dryer Exhaust Duct Power Ventilator (DEDPV) IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPOTANTES POUR LA SÉCURITÉ SAVE THESE INSTRUCTIONS CONSERVEZ CES INSTRUCTIONS DEDPV-705 KIT INCLUDES: Inline Fan with Integral Control, 1 pc 2 ft Section of Tubing, 2 pcs FC4 Clamps, 4 pcs Grommet for Tubing, 1 pc...
  • Page 2: Table Of Contents

    A Dryer Exhaust Duct Power Ventilator (DEDPV) is a term used for an appliance specifically designed to assist a single residential dryer (gas or electric) in overcoming dryer performance loss caused by long or restrictive duct configurations. Dryer Exhaust Duct Ventilator differs from the term dryer booster in that the ventilator must comply with stringent application specific safety requirements.
  • Page 3: Safety Instructions

    Safety Instructions Note Warning / Information Technical Practical tip Important information note Read and Save these instructions for future reference. WARNING- TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Your clothes dryer installation incorporates a dryer exhaust power ventilator (DEDPV) which may be in a different location than your dryer, such as in an attic, crawl space or basement.
  • Page 4 CAUTION: • Do not install in exhaust ductwork of a clothes dryer whose instructions prohibit the installation of a clothes dryer booster fan (DEDPV). • Do not install in exhaust ductwork where the equivalent duct length is < 25 ft (7.62 metres). The DEDPV-705 is suitable to overcome an equivalent duct length of 125 feet (38 meters) of 4 inch diameter galvanized steel duct, and to maintain an air velocity of 1200 fpm (6.10 m/s).
  • Page 5: Installation

    Installation This is a cord connected appliance; not intended to be field wired. Accessing or tampering with the electrical enclosure voids the UL marking and manufacturer’s warranty. Use this product in the manner intended by the manufacturer. For additional questions, contact Fantech Technical Services. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 6: Duct Installation (Step 4)

    a) Hold the mounting bracket against the surface it is to be mounted. b) Mark the location of the two most useful key slots and remove the bracket. Using the provided ¾” long wood screws, attach screws into the structure leaving 1/8” space between the screw head and mounting surface. c) Using the provided self-tapping screws, attach the bracket to the fan as shown.
  • Page 7: Sequence Of Operation

    SEQUENCE OF OPERATION 1. Apply power to the DEDPV-705 The blue light on the indicator panel only illuminates when the DEDPV-705 is operating. 2. The DEDPV-705 turns ON approximately 10 seconds after the dryer has started by sensing the pressure inside the exhaust duct. A blue LED will illuminate (solid) on the indicator panel when the DEDPV is operating.
  • Page 8: Troubleshooting

    TROUBLESHOOTING No Indicator Light | DEDPV not operating when dryer runs Check that the pressure tube is free of moisture, cracks, and properly inserted into the exhaust duct upstream of the fan. Solution: The DEDPV-705 is interlocked to the dryer by sensing the pressure inside the exhaust duct when the dryer turns on. Replace the tubing if damage is observed Verify that the low voltage wiring is properly plugged into the DEDPV-705.
  • Page 9: Warranty

    WARRANTY Five (5) Year Warranty This warranty supersedes all prior warranties DURING ENTIRE WARRANTY PERIOD: Fantech will repair or replace any part which has a factory defect in workmanship or material. Product may need to be returned to the Fantech factory, together with a copy of the bill of sale and identified with RMA number. FOR FACTORY RETURN YOU MUST: •...
  • Page 12 Fantech reserves the right to make technical changes. For updated documentation please refer to www.fantech.net Fantech®...