1
6
7
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/ADVERTISEMENT
Risk of electrical shock. Disconnect power before
servicing or installing product.
Risque de choc électrique. Couper l'alimentation
avant le dépannage ou avant l'installation du produit.
imagination at work
2
3
5
8
9
10
1
UL approved 18 AWG (0.82 mm
4
2
UL approved 22-14 AWG (0.33-2.08 mm
wire connectors or 22-18 AWG
(0.33-0.82 mm
3
#6 or #8 (M3 or M4) screws or 1/8 inch
(3.2 mm) rivets
4
End caps (GETMEC1)
5
®
Tetra
Power Supply (GEPS12-20,
GEPS12-60, GEPS12-60U)
6
®
Tetra
PowerStrip LED modules
(GEWHSSP3-65K, GEWWSSP3-41K)
OPTIONAL
7
®
Tetra
PowerStrip Assembly Support
(GEDSAS1)
8
Tetra
®
PowerStrip Tube Connector (GEDSTC1)
9
Tetra
®
PowerStrip Assembly End Cap
(GEDSMB1)
10
Tetra
®
PowerStrip Tube (GEDSAT96)
Prepare Electrical Wiring
Electrical Requirements
• Do not use in wet locations.
• The grounding and bonding of the LED
Driver shall be done in accordance with
National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and
local codes.
Installation Guide
) supply wire
2
) in-line/IDC connectors
2
12
Volt
)
2

Advertisement

loading

Summary of Contents for GE Tetra PowerStrip GEWHSSP3-65K

  • Page 1 Installation Guide Lumination Volt PowerStrip Tetra ® LED Lighting System (GEWHSSP3-65K, GEWWSSP3-41K) Components UL approved 18 AWG (0.82 mm ) supply wire UL approved 22-14 AWG (0.33-2.08 mm wire connectors or 22-18 AWG (0.33-0.82 mm ) in-line/IDC connectors #6 or #8 (M3 or M4) screws or 1/8 inch (3.2 mm) rivets End caps (GETMEC1) ®...
  • Page 2 Retrofit Preparation Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes 0.5 in. (13mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13mm), use an aluminum or zinc coated steel patch with rivets and sealant.
  • Page 3 Electrical Connections NOTE: Refer to the power supply installation instructions for loading and remote mounting information. White (-) Red stripe (+) Connect modules using twist-on wire connectors Cap all exposed wires with appropriate end caps. or in-line (IDC) connectors. Join white wires together and red striped wires together.
  • Page 4 (1.888.694.3533) Lumination, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of Lumination, LLC. The GE brand, logo, and ecomagination are trademarks of the General Electric Company. © 2009 Lumination, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

This manual is also suitable for:

Tetra powerstrip gewwssp3-41k