Air particles, water vapor, oil based contaminants or other liquids, can be harmful to the blower and may cause over-heating. The use of an air-filter, relief valve, and pressure gauge are highly recommended in conjunction with our blowers. When using the blower at a high altitude or high temperatures, please consult with Atlantic Blowers prior to use. Safety Notice To ensure safe operation, we have provided many important safety guidelines in this manual for the Atlantic Regenerative Blower.
1-3 Plumbing Remove any foreign material (burrs, chips, welding drops, slag, pipe cuttings, excess sealant, sand, lime, etc.) from plumbing. Verify the motor is securely mounted and has proper impeller rotation before connecting to plumbing. The inlet and outlet ports are not designed to support the plumbing without proper structural reinforcement.
This product must be properly grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. If the grounding instructions are not completely understood, or if you are not sure whether the product is properly grounded, check with a qualified electrician or serviceman.
Page 5
Standard Installation Layout Pressure Application – Standard Installation Layout Vacuum Application –...
3 Maintenance Failure to follow these instructions can result in death, fire or electrical shock x Disconnect electrical power supply cord before performing maintenance on the blower. x If product is hard wired into system, disconnect electrical power at the circuit breaker or fuse box before performing maintenance on the blower.
Troubleshooting Chart Problem Reason Remedy Increased Sound Noise absorbing foam is Replace foam damaged Replace bearings Impeller may be rubbing Send unit to an authorized casing inside the blower Atlantic Repair Facility Excessive Vibration Damaged impeller Replace impeller Impeller is dirty Clean impeller Add vibration isolators Improper mounting...
Page 10
ITEM PARTS NAME ITEM PARTS NAME ITEM PARTS NAME ITEM PARTS NAME Single Stage Only Impeller 007-04 Wire mounting block Rotor pin Blower cover/ Wire connection Capacitor mounting 007-05 Bearing washer 007-10 back plate jumper/bridge bracket Blower housing 007-06 Fixed terminal Washer 007-11 Capacitor...
Frequently Asked Questions (FAQ’s) 1) Q - What maintenance does my blower require? A- Virtually none, there is no need to grease/oil the bearings as they are sealed and already lubed when you receive your new blower. Bearings are designed to last at a minimum, 20,000 hours.
During the labor warranty period, to repair the Product, Purchaser will either return the defective Product; freight prepaid, or deliver it to an Atlantic Blowers Service Center or to a service facility authorized by Atlantic Blowers. The Product to be repaired is to be returned in either its original carton or a similar package affording an equal degree of protection.
Page 16
LIMITATION OF LIABILITY THE LIABILITY OF ATLANTIC BLOWERS, IF ANY, AND PURCHASER’S SOLE AND EXCLUSIVE REMEDY FOR DAMAGES FOR ANY CLAIM OF ANY KIND WHATSOEVER, REGARDLESS OF THE LEGAL THEORY AND WHETHER ARISING IN TORT OR CONTRACT, SHALL NOT BE GREATER THAN THE ACTUAL PURCHASE PRICE OF THE PRODUCT WITH RESPECT TO WHICH SUCH CLAIM IS MADE.
Need help?
Do you have a question about the AB-70 and is the answer not in the manual?
Questions and answers