PASCO PASPort PS-2170 Instruction Manual

PASCO PASPort PS-2170 Instruction Manual

Chemistry multimeasure sensor

Advertisement

Quick Links

Chemistry MultiMeasure Sensor
1
Included Equipment
1. Chemistry MultiMeasure Sensor
2. Stainless Steel Temperature Probe
3. Voltage Probe
4. pH Electrode
5. Polyurethane Tubing (60 cm, 0.125 inch ID)
6. Quick-release Connectors (qty. 4)
7. Tubing Connectors (qty. 4)
8. Syringe (60 cc)
9. Alligator Clip with Insulator (qty. 2 each)
Polyurethane Tubing, (blue, 15 cm, 0.25 inch OD)
Required Equipment
PASPORT Interface and
Data Acquisition Software
PS-2170
2
3
4
5
8
Note
See PASCO catalog or
www.pasco.com
Instruction Manual
6
7
9
Model Number
PS-2170
PS-2153
PS-2165
PS-2573
Hose and Coupling Kit
not shown
012-09523B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PASPort PS-2170 and is the answer not in the manual?

Questions and answers

Summary of Contents for PASCO PASPort PS-2170

  • Page 1 7. Tubing Connectors (qty. 4) 8. Syringe (60 cc) 9. Alligator Clip with Insulator (qty. 2 each) Polyurethane Tubing, (blue, 15 cm, 0.25 inch OD) not shown Required Equipment Note PASPORT Interface and See PASCO catalog or Data Acquisition Software www.pasco.com...
  • Page 2 For detailed information about each of the multi-sensor sensor’s component sensors see pages 4–6. Follow the instructions in the Computer Setup section to set up the sensor with a PASPORT-compatible interface connected to a computer using PASCO Capstone or PASPORT SPARKvue HD software.
  • Page 3: Computer Setup

    Using PASCO Capstone • Connect a PASPORT-compatible interface to the computer and start the PASCO Capstone software. (Refer to the documentation that came with your PASPORT interface for instructions on connecting it to your computer.) In Capstone, click the Record button to begin data collection; click the Stop...
  • Page 4: Calibration Information

    °C, °F, or K. You can use the included stainless steel probe or a different probe, such as the Fast-response Temperature Probe (PS-2135) or Skin/Surface Temperature Probe (PS-2131). PASCO apparatus containing an embedded 10 k thermistor can also be connected to the multi-sensor. The multi-sensor automatically detects the presence of a temperature probe, and it will only collect temperature data if a probe is connected.
  • Page 5 M o d e l N o . P S- 2 1 7 0 p H / I S E / O R P Connect the pH electrode (or other electrode) to the pH/ISE/ORP port and start data collection. On your computer or interface, display the ISE Voltage measurement (this measurement is valid for pH and ORP electrodes as well as ISE) or the pH mea- surement for the calculated pH (assuming that the pH electrode is connected).
  • Page 6: Specifications

    C h e m i s t r y M u l t i M e a s u r e S e n s o r Pressure Pressure Pressure Port This component of the multi-sensor measures absolute gas pressure from 0 kPa to 700 kPa.
  • Page 7 M o d e l N o . P S - 2 1 7 0 S p e c i f i c a t i o n s Voltage 10 V to  10 V Range  0.1 V Accuracy ...
  • Page 8: Appendix A: Pasco Capstone Calibration

    Appendix A: PASCO Capstone Calibration In PASCO Capstone, click the Hardware Setup icon in the tools palette to open the Hardware Setup panel. Confirm that the icon of the sensor appears with the icon of the interface being used. Click the Hardware Setup icon again to close the panel.
  • Page 9: Appendix B: Sparkvue Hd Calibration

    You can use the SPARKvue HD software if you are using the Chemistry MultiMeasure Sensor with a PASPORT-compatible interface connected to a computer, or with a mobile device paired with a PASCO wireless interface, such as the AirLink2 or SPARKlink Air. If the sensor is connected to a PASPORT-compatible interface, start the SPARKvue software on the computer.
  • Page 10: Appendix C: Spark Sls Calibration

    C h e m i s t r y M u l t i M e a s u r e S e n s o r Spe c ificati ons Appendix C: SPARK SLS Calibration For a two-point calibration of the pH Probe, you will need two “known stan- dards,”...
  • Page 11 M o d e l N o . P S - 2 1 7 0 S p e c i f i c a t i o n s Use the down arrow (d) to highlight “Pt 1 (mV)”. (NOTE: If you need to change the Standard Value, highlight Pt 1 (pH), press “Check”, and use the key- pad to enter the correct Standard Value.) Put the Chemistry Sensor’s pH Probe into the first “known standard”...
  • Page 12: Technical Support

    PASCO, PASCO scientific, PASCO Capstone, MultiMeasure Sensors, PASPORT, SPARK Science Learning System, SPARKvue, and Xplorer GLX are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of, their respective owners. For more information visit www.pasco.com/legal.

Table of Contents