Event Description
Repeater missing trouble restore
Repeater Rx1 communication
trouble
Repeater Rx1 communication
trouble restore
Repeater Rx2 communication
trouble
Repeater Rx2 communication
trouble restore
SBUS Class A supervision lost
SBUS Class A supervision re-
store
SBUS expander trouble
SBUS expander trouble restore
SLC class A supervision trouble
SLC class A supervision trouble
restore
SLC programming ended, system
active
SLC programming started, sys-
tem shut down
SLC short circuit trouble
SLC short circuit trouble restore
Time changed event
Unable to report to account
trouble
Unable to report to account
trouble restore
User access code changed
User initiated manual dialer test
Walk test begin
Walk test end
Table 12.2 Zone Events
Auxiliary power trouble
Auxiliary power trouble restore
CO Detector Alarm
CO Detector Alarm Restore
CO Detector Supervisory Alarm
CO Detector Supervisory Alarm
Restore
CO Detector Trouble
CO Detector Trouble Restore
Detector Alarm
Detector Alarm Restore
Detector trouble
Detector trouble restore
163
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter Fixed Length
ID # (If
Event
Any)
Codes
EN
0100
EM
0101
EN
0101
EM
0102
EN
0102
ET
Exp. ID
ER
Exp. ID
ET
Exp. ID
ER
Exp. ID
ET
Exp. ID
ER
Exp. ID
TE
0
TS
0
ET
Exp. ID
ER
Exp. ID
JT
0
RT
Receiver # RTNN00RRRR
YK
Receiver # YKNN00RRRR
JV
0
RX
0
TS
0
TE
0
Note:
Zone events are reported only when "Report by Zone" is selected
FT
0000
FJ
0000
GA
Zone #
GH
Zone #
GS
Zone #
GR
Zone #
GT
Zone #
GJ
Zone #
FA
Zone #
FH
Zone #
FT
Zone #
FJ
Zone #
Table 12.3 : Report Formats Table
IFP-300 / IFP-300ECS Manual P/N LS10145-001SK-E:B 12/18/2017
Contact ID Reporting Format
SIA
Qualifier
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
ENNN000100
3
EMNN000101
1
ENNN000101
3
EMNN000102
1
ENNN000102
3
ETNNXX0000
1
ERNNXX0000
3
ETNNXX0000
1
ERNNXX0000
3
ETNNXX0000
1
ERNNXX0000
3
TENN000000
3
TSNN000000
1
ETNNXX0000
1
ERNNXX0000
3
JTNN000000
1
1
3
JVNN000000
1
RXNN000000
1
TSNN000000
1
TENN000000
3
FTNN000000
1
FJNN000000
3
GANN000ZZZ
1
GHNN000ZZZ
3
GSNN000ZZZ
1
GRNN000ZZZ
3
GTNN000ZZZ
1
GJNN000ZZZ
3
FANN000ZZZ
1
FHNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
Event
Group #
Contact #
Code
334
Panel ID
100
334
Panel ID
101
334
Panel ID
101
334
Panel ID
102
334
Panel ID
102
333
Exp. ID
000
333
Exp. ID
000
333
Exp. ID
000
333
Exp. ID
000
331
Exp. ID
000
331
Exp. ID
000
607
00
000
607
00
000
332
Exp. ID
000
332
Exp. ID
000
625
00
000
354
00
Receiver
#
354
00
Receiver
#
602
00
000
601
00
000
607
00
000
607
00
000
320
00
000
320
00
000
162
00
Zone #
162
00
Zone #
200
00
Zone #
200
00
Zone #
373
00
Zone #
373
00
Zone #
110
00
Zone #
110
00
Zone #
373
00
Zone #
373
00
Zone #

Advertisement

Table of Contents
loading

This manual is also suitable for:

Farenhyt ifp-300Farenhyt ifp-300ecs

Table of Contents

Save PDF