1
1
Reading Window
2
Positioning LED
3
Keypad button
4
Calibration LED
For further details on product installation, see the complete Installation Manual available on
the CD included with this product.
NOTE
Compliance:
- This product is intended to be installed by Qualified Personnel only.
- This product is intended to be connected to a UL Listed
Computer which supplies power directly to the reader or a
UL Listed Direct Plug-in Power Unit marked LPS or
"Class 2", rated 10 to 30 V, minimum 1 A.
- In order to meet the EMC requirements:
connect reader chassis to the plant earth ground by
means of a flat copper braid shorter than 100 mm;
connect the main interface cable shield to pin 1 of the
reader 25-pin connector;
use two clip-on ferrite sleeves (type Stewart 28A2029-
0A0) on the main interface cable near the reader 25-
pin connector;
connect the Ethernet interface cable shield to the
reader chassis (for Matrix-21XX only)
Model Description:
Device Connectivity
0 = RS232/RS485 + RS232
1 = RS232/RS485 + RS232+ Ethernet
Matrix-2000™
Quick Reference Guide
5
6
7
8
Figure A
5
Communication LED
6
Main/Auxiliary Interface
Ethernet Interface (for 21XX
7
models only)
MATRIX - 2XXX-X
Optics
1 = Ultra High Density (UHD)
2 = High Density (HD)
3 = Standard Density (SD)
4 = Low Density (LD)
5 = Medium Range (MR)
6 = Long Range (LR)
10
11
9
Auxiliary Interface
8
Good Read LED
9
10 External Trigger LED
Power On LED
11
TO EN 60825-1:2001
Image Sensor
1 = VGA CCD
5 = SXGA CMOS
4
3
2
Other Options
R = 90° Reading Window

Advertisement

loading
Need help?

Need help?

Do you have a question about the Matrix-2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Datalogic Matrix-2000

  • Page 1 Matrix-2000™ Quick Reference Guide Figure A Reading Window Communication LED Auxiliary Interface Positioning LED Main/Auxiliary Interface Good Read LED Keypad button 10 External Trigger LED Ethernet Interface (for 21XX models only) Calibration LED Power On LED For further details on product installation, see the complete Installation Manual available on the CD included with this product.
  • Page 2 121 x 73 x 57 mm (4.76 x 2.87 x 2.24 in.) Weight 380 g. (13.40 oz.) Material Magnesium alloy A special Application Program to read Pharmacode, RSS, QR code, Aztec Code, MaxiCode and other symbologies is available on request. Please refer to your local Datalogic Distributor.
  • Page 3: Environmental Features

    IEC 68-2-27 test EA 30 G; 11 ms; 3 shocks on each axis Protection class IP64 (Matrix-20XX models only) Please refer to your local Datalogic Distributor for IP64 Protection class on 21XX models. READING FEATURES Up to 60 frames/sec 2XX1 Models Frame rate Up to 16 frames/sec.
  • Page 4 GFC-MATRIX-2000 90° deflection mirror Electrical Connections The Matrix-2000™ reader provides a 25-pin male D-sub connector for connection to power supply, Host interface (Main and Auxiliary), and input/output signals. A separate 9-pin female D-sub connector provides access to the auxiliary port.
  • Page 5 The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 25-pin D-sub female 9-pin D-sub female TXAUX RXAUX MATRIX EXT TRIG+ EXT TRIG- Power Supply VS (10 – 30 VDC) Power GND Trigger Test Cable for Matrix-2000™...
  • Page 6 MATRIX-2000™ QUICK GUIDE C-BOX 100 Pinout for Matrix-2000™ The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the Matrix- 2000™ reader is connected by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors...
  • Page 7 Input / Output Connections: Inputs Vext MATRIX MATRIX USER INTERFACE USER INTERFACE 30 Vdc Max. Input PNP command using Matrix-2000    power Input PNP command using external power MATRIX MATRIX USER INTERFACE USER INTERFACE Vext 30 Vdc Max.
  • Page 8 MATRIX-2000™ QUICK GUIDE Mechanical Installation: [2.24] [2.87] [inch] 18.1 [2.24] [0.71] M4 x 5 n°4 Overall dimensions - Standard model [2.87] [1.46] [inch] [2.87] [0.59] [0.08] [inch] [0.17] Overall dimensions - 90° model Mounting Bracket Dimensions...
  • Page 9 MATRIX-2000™ QUICK GUIDE Connectivity Point-to-Point Multiplexer Terminal CAB-600X Matrix-2000™ C-BOX 100 MX4000 Power Matrix-2000™ C-BOX 100 C-BOX 100 C-BOX 100 Local Host P.S. PG6000 Multidrop Network - RS485 HD Main Interface Main Serial Interface Auxiliary Serial Interface RS232 Auxiliary Interface (Local Echo)
  • Page 10 (refer to the Reading Features table). Power up the Matrix-2000™ and press the keypad button positioned on top of the reader for at least 2 seconds; Matrix-2000™ will emit 3 high pitched beeps and the POS and CAL LEDs will start blinking. Slow blinking means that positioning and calibration values must be improved.
  • Page 11 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el MATRIX-2XXX e tutti i suoi modelli and all its models et tous ses modèles...