Installation ® Setting up your CleverSpa 07 - 08 ® Operating your CleverSpa ® Maintenance & Repair of your CleverSpa ® Cleaning & Storing away your CleverSpa ® Troubleshooting Returns Warranty IMPORTANT SAFETY INSTRUCTIONS - READ, FOLLOW AND SAVE ALL INSTRUCTIONS...
C onsult your doctor before use as some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation. g) T o accurately check the water temperature we recommend the use of a calibrated digital thermometer or mercury thermometer, ensuring this matches with the spa control panel (see page 10 regarding how to operate your hot tub). • H ypothermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37°C (98.6°F). The symptoms of hypothermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. T he effects of hypothermia include failure to perceive heat, a failure to recognise the need to exit the CleverSpa , an unawareness of impending hazards, fetal damage in pregnant women, a physical inability ® and unconsciousness resulting in the danger of drowning. WARNING – The use to exit the CleverSpa ® of alcohol, drugs, or medication can greatly increase the risk of fatal hypothermia. SAVE THESE INSTRUCTIONS SPECIFIC REQUIREMENTS FOR THE SUCTION FITTING • R equired replacement of the suction fitting may only be performed by authorised representatives of Clever Company Limited.
DRAINAGE PLUG (G) SAFETY LOCKING CLIP KEYS (H) PRODUCT SPECIFICATION 71” CIRCULAR 82” CIRCULAR 73” X 73” SQUARE 71” CIRCULAR ETL Model Number: 10001 10002 10003 10004 Capacity 2-4 People 4-6 People 4-6 People Up to 7 People Water Capacity (approx.)
BEFORE YOU SET UP YOUR CLEVERSPA ® Before setting up outdoors Before setting up indoors 1. Y ou must have solid support foundation where 1. F loor must be able to withstand you install your CleverSpa . When setting up, weight of the CleverSpa + occupants. ® ® ensure there are no sharp objects that could 2. Floor should be a non-slip, level surface. damage the CleverSpa and the location is level ® 3. Suitable drainage is essential when so the CleverSpa sits properly. ® installing your CleverSpa indoor.
SETTING UP YOUR CLEVERSPA ® L ay out groundsheet (A) on Unpack CleverSpa on Unfold the CleverSpa ® , ensuring ® a flat even surface, clear of any groundsheet. sides are as upright as possible. sharp objects. Uncoil cord and RCD/GFCI Connector Locations: Remove protective plastic plug, located under built-in Air Outlet (J), Inflation Valve (K) from connectors. control unit. and Water Outlet (L). Unscrew outer cap from Inflation Unscrew cap from Air Outlet (J).
Page 8
Connectors (N1 & N2). (N1 & N2) Drainage Plug (G). Filter Cartridges (B). Set temperature on control panel*. Add water to level, no Double lock clips with Clip on Top Cover (E) to retain the heat. Safety Locking Keys (H). higher than ‘Max’ level. *See page 10 for full operating instructions. You can also see our Clever Clips on how to setup your CleverSpa just visit clevercompany.com ®...
OPERATING YOUR CLEVERSPA ® SETTING THE TEMPERATURE INFLATE/AIR JETS Press ‘SET TEMP/LOCK’ and the numbers on Press ‘INFLATE/AIR JETS’ to start air jets - a red display screen will start to flash. Increase/ light will appear. Press again and air jets will decrease temperature by pressing ‘TEMP UP’ stop working - red light will go out. or ‘TEMP DOWN’. Air jets stop automatically after 20 minutes. Choose desired temperature, press ‘SET TEMP/ To reset, wait for 10 minutes and press LOCK’ again to confirm. Temperatures can be ‘INFLATE/AIR JETS. Air jets can be stopped/ set between the range of 20°C to 40°C started any time during their 20 minute cycle. F - 104 F). (See safety instructions for Air Jets will stop after 20 minutes to avoid recommended operating temperatures).
MAINTENANCE & REPAIR OF YOUR CLEVERSPA ® WATER LEVEL Water should be filled and maintained between ‘Min’ and ‘Max’ fill lines as indicated on inner wall of your CleverSpa ® IMPORTANCE OF WATER TREATMENT You need to regularly monitor and appropriately treat the water in your CleverSpa ® PEOPLE WITH THE FOLLOWING TRAITS ARE AT HIGHER RISK INCLUDING: • Diabetes, lung and heart disease • Smokers and heavy drinkers • Anyone with an impaired immune system • People suffering from chronic respiratory or kidney disease. For more information contact your doctor. WATER AND LEGIONNAIRES DISEASE? Legionnaires’ disease can be contracted by inhaling small droplets of water (called aerosols), which are suspended in the air and contain the bacteria. Certain conditions increase the risk of Legionella if: • W ater temperature in all or some parts of the system is between 20-45°C (68°F-113°F), which is suitable for growth of the bacteria.
3. R eplace the filter protector cover (C) over the filter cartridge (B) and attach FILTER PROTECTOR to the filter connector (N1 & N2) by turning it clockwise until hand tight. COVER (C) To help to keep your water clean, check your filter cartridge every day. To order filters and chemicals for your CleverSpa , please visit: clevercompany.com ®...
A1 Air pump too hot A1 U nplug system. After air pump has is not operating cooled, insert plug and press air jets A2 S omething wrong with button to activate power box A2 Wait for 10 Minutes and restart A3 A ir Pump in cooling mode A3 C all CleverSpa Aftersales if does not reset ® Heating system A1 Temperature is set too low A1 S et to a higher temperature 20-40°C does not operate F-104 F) than current water temperature...
RETURNS CHANGED YOUR MIND AND NEED TO RETURN YOU HOT TUB? PLEASE FOLLOW THE BELOW INSTRUCTIONS: • If you have purchased a CleverSpa and have simply changed your mind, follow the retailers instructions ® for returns. You will need to register your warranty at: clevercompany.com/support/warranty and will require proof of purchase. DEFECTIVE ITEMS If your item is defective in any way, i.e. it doesn’t work but you can’t identify why, in the first instance please consult our FAQ section at clevercompany.com as there may be a simple solution to the issue, if this does not help to resolve the issue, email: support.usa@clevercompany.com for assistance. DAMAGED ITEMS If you receive an order with obvious shipping damage from the retailer, then we suggest the delivery is refused. If the delivery has been accepted and then shipping damage is found, please follow the specific instructions advised by the retailer. In all circumstances please save all packaging material and paperwork for the order. Please be aware that if you dispose of packaging material or attempt to return the merchandise without contacting the fulfiller, you jeopardise your chances of making a claim, and you may not receive a credit for the return. LIMITS OF RESPONSIBILITY CleverSpa accept no responsibility for misuse or user damage and/or loss of parts incurred during ®...
WARRANTY REGISTERING YOUR WARRANTY To register your warranty, visit clevercompany.com/support/warranty and complete the form within 28 days of purchase. The warranty will start from the date of purchase which must be verified by proof of purchase. For up-to-date troubleshooting advice, technical information and FAQs please visit our online help centre at support.usa@clevercompany.com. WARRANTY CLAIMS Before making a claim, we may be able to answer your query, simply visit clevercompany.com/support/ cleverspa-faqs for further information. If the FAQs don’t solve the issue and you need to make a claim, please ensure that you have registered your warranty and contact us by email at: support.usa@clevercompany.com. Our dedicated Aftersales Team will endeavour to answer all messages within 48 hours.
Page 16
SAFETY SIGN POSTING Please post the ‘Safety Sign’ provided in an area visible to all users of the hot tub, to alert them of the safety rules and warnings. REPLACEMENT SAFETY SIGN To obtain additional or a replacement ‘Safety Sign’, please contact Clever Company on support.usa@clevercompany.com.
Need help?
Do you have a question about the 10001 and is the answer not in the manual?
Questions and answers
I have a cleaver spa and I carnt get the temperature past 37degress how do I get the temperature back up to 40degress