➢ Warranty Department – warranty claim issues. Available from 8 a.m. to 5 p.m. EST, Monday- Friday. ➢ Technical Support Department – technical issues related to the function and repair of Rinnai products. Available in the office from 8 a.m. to 8 p.m. EST, Monday – Friday AND 24/7/365 on call support for...
2. All major replacement parts are accompanied with replacement procedures. 3. Rinnai will pay reasonable labor for warranty parts changed during the labor warranty period. Normally one hour labor will be paid for most parts and two hours for the heat exchanger.
Page 7
Manometer (Volt/Ohm Meter) If Rinnai technical support assistance is required please have these tools available in order to speed up the troubleshooting process. Also, Rinnai needs to know the full model and serial number of the product. Have the front cover removed from the product, record and provide any relevant information such as gas pressures, set temperature, fault codes etc.
Water Heater DISASSEMBLY & REASSEMBLY The following procedures are for KB series water heaters. Other Rinnai models may vary slightly in design and service requirements. Please refer to each model’s install guide and service documentation for model specific information. PLEASE STAY WITH THE PRESENTATION DURING DISASSEMBLY AND REASSEMBLY.
Front Panel Information Located inside the front cover panel of all Rinnai Tankless water heaters you will find a wiring diagram and technical data sheet. The technical data sheet contains operation, troubleshooting and service information including: Technical data sheet • Error code information •...
Page 15
Overheat Protection and Safeties The Rinnai Safety “Line of Defense” Multiple layers of technology ensure safe operation If the heat exchanger If the outlet If the overheat If the heat exchanger If the thermal thermistor detects thermistor detects bimetal detects...
On the other hand an incorrect value is a very good indication that the component is defective. For metering values, reference Rinnai’s Tankless Water Heater Service Manual —the “Electrical Diagnostic Points” section (model dependent) or each unit’s technical data sheet located inside the front cover.
- Turn off all hot water tap. Disable bath fill, turn unit OFF then back ON. Bypass Servo failure - Replace bypass servo. - Ensure Rinnai approved venting materials are being used. - Check that nothing is blocking the flue inlet or exhaust. - Check all vent components for proper connections.
Page 81
• If any symptom exists suggesting a gas supply issue may be present, a gas manometer will be needed to verify incoming pressure. Rinnai tankless water heaters only need a single port manometer. Dual port or pressure differential manometers are not needed. Various...
TROUBLESHOOTING SUMMARY WHEN TROUBLESHOOTING IT IS IMPORTANT TO REMEMBER…. •REMEMBER ALL RESOURCES AVAILABLE TO YOU!! • Rinnai documentation (Tech Service Manual, Installation Manuals, Tech Data Sheets). • Rinnai Support •Technical Support and Engineering Phone Support. •Local Support (Sales representatives, distributors, etc.) •...
Page 85
General Troubleshooting Summary Basic Troubleshooting this is a general guide and not intended as an official troubleshooting procedure - contact Rinnai technical support if needed. ELECTRICITY WATER Verify correct venting Verify input power Verify flow Verify incoming pressure Verify correct parts, seals, custom cuts,...
Need help?
Do you have a question about the RUC80i and is the answer not in the manual?
Questions and answers