The fuel to be charged to the burner must be kept in a solid, sealed container (a bunker) and handled to the burner via a screw (auger) fuel feeder from VENMA with properly selected length and power output.
B U R N E R S 2. Burner design The VENMA burner comprises steel components and electrical parts. The combustion chamber and the grate of the burner are made of heat-resistant stainless steel. The steel material has been tested for resistance at temperatures above 1,000°C. The fuel feeder duct is made from galvanized black steel for corrosion protection throughout the operating life.
Standard 2 m long galvanized steel fuel feeder (a longer option is available on request) Flex tube, 1 m long Installation flange (optional)* * Standard feature for 100 kW or higher-rated burners Fuel charging hopper with a fire damper Ceramic gasket VENMA Operating & Maintenance...
DO NOT SELECT “FIRING UP” IF YOU ARE NOT SURE THAT THE COMBUSTION CHAMBER AND THE FLEX PIPE ARE EMPTY. EXPLOSION HAZARD! 16. With the foregoing steps completed, you may operate your VENMA burner; ref. the control unit user manual for the configuration settings.
Page 6
P E L L E T B U R N E R S VENMA Comfort 16-35 burners Model: Power Max. current input: Weight: range: (Firing-up / Combustion) [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] Comfort 16 4-16 kW 300/70 W...
P E L L E T B U R N E R S FIG. 2 6. Fuel specifications The fuel for the burner shall conform to the following specifications: Form Granulated Diameter 6-8 mm Length 3-40 mm Dust fraction ≤1% Fuel density ≥620 kg/m Moisture content...
8. Operating the burner The burner shall be installed and operated according to this Manual and the Warranty Certificate. VENMA shall not be liable for any damage resulting from improper use of the burner. The burner shall be cleaned and maintained according to the sound judgement of the user.
P E L L E T B U R N E R S 9. Inspection of the burner To ensure trouble-free operation of the burner for many years, proper maintenance must be performed. It is highly recommended to order an authorized technical service for an annual inspection of the burner after each heating season.
Page 10
P E L L E T B U R N E R S Flame sensor (photo-sensitive devide) Air fan port • Cleaning the flame sensor (photo-sensitive device): remove the flame sensor carefully by pulling it out towards you and clean with a dry cloth. Reinstall the flame sensor in the rubber gland.
P E L L E T B U R N E R S FAQ (Frequently Asked Questions) Error Alarm / Notification Potential cause - No fuel left in the bunker; restock and prime the fuel feeder duct in manual control mode;...
Page 12
P E L L E T B U R N E R S Pumps or Space Heating. - The CH Pump Room option is enabled. - The control unit operates in the Summer Mode. Change the Running Mode to Parallel The DHW pump fails to start when it reaches Pumps or Boiler in Priority.
P E L L E T B U R N E R S Installation Report Buyer’s data: Location: Postal code: City: Street address: Phone: E-mail: Reseller’s data: Location: Postal code: City: Street address: Phone: E-mail: Burner installer’s data: Location: Postal code: City: Street address: Phone:...
P E L L E T B U R N E R S Warranty Certificate Periodic, warranty and post-warranty burner inspection Date: Service engineer’s stamp and legible Inspection type and Report signature: no.: NOTICE!!! Each inspection on site shall have the Inspection Report filled out and signed by the service engineer.
(provided that the product passes an periodic inspection after every 12 months of operation). 2. All workmanship defects found in the product will be removed at VENMA’s cost in 21 business days from filing the warranty claim. 3. The scope, method and terms of warranty repair are solely at VENMA’s discretion.