Installation
The water connection pressure needs
to be between 200 kPa and 800 kPa
(2 bar and 8 bar).
Risk of damage due to excessive
water pressure.
Excessive water pressure in the pipe
can cause damage to the appliance.
Install a pressure reducing valve if
the water pressure in the system
exceeds 800 kPa (8 bar).
Do not install the system if the water
pressure exceeds 830 kPa (8.3 bar).
Contact a plumbing specialist if you
are unsure of your water pressure.
Use fresh water to ensure a perfect
quality of the ice cubes. Connect the
stainless steel hose to the fresh
water supply and avoid connection
to a water supply in which the water
might stagnate.
Only use the stainless steel hose
supplied. Old or used hoses must
not be connected to the appliance.
The stainless steel hose must not be
shortened, extended or replaced by
another hose.
The stainless steel hose must only
be replaced by an original Miele
spare part. A stainless steel hose
which is suitable for use with
drinking water is available to order
from Miele (see back cover for
contact details).
A tap must be provided between the
stainless steel hose and the mains
water supply to ensure that the water
supply can be shut off if necessary.
54
The tap should be easily accessible
after the appliance has been built in.
The stainless steel hose is 2 m long and
is already installed on the refrigeration
appliance when it is delivered.
Connecting the appliance to the
mains water supply
By this time, the installation niche
should already be prepared so that the
appliance only needs to be pushed into
it.
When doing so, make sure that the
stainless steel hose is not kinked or
damaged.
 Position the appliance slightly in front
of the niche.
The stainless steel hose  of the
refrigeration appliance is ready for
connection.