Download Print this page

Advertisement

Quick Links

Monteringsanvisning
NO
Installation- and user manual
GB
Montageanleitung
DE
Manuel d'installation
FR
Bruksanvisning
SE
Asennusohje
FI
Product no:
46378757/ 46378761/ 46378776/ 51204962
Last updated: 03.01.2018
Test report no: Uno 1, 2, 4 - SP: 3P01611, RRF: 40 13 3258,
Uno 5 - RRF: 40 16 4289
Uno 1, 2, 4, 5
2
10
17
28
36
43

Advertisement

loading
Need help?

Need help?

Do you have a question about the Uno 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nordpeis Uno 1

  • Page 1 Monteringsanvisning Installation- and user manual Montageanleitung Manuel d’installation Bruksanvisning Asennusohje Product no: 46378757/ 46378761/ 46378776/ 51204962 Last updated: 03.01.2018 Test report no: Uno 1, 2, 4 - SP: 3P01611, RRF: 40 13 3258, Uno 5 - RRF: 40 16 4289...
  • Page 2 INDEX 1. Please follow the installation manual when Chimney draught Air supply 2. Technical information pipe to the surrounding materials. 3. Distance to combustible material 2. Before use, please carefully read the user manual and follow the instructions. Releasing the stove from the pallet Operating control never be reduced or partially obstructed.
  • Page 3: Technical Information

    Installation of the insert must comply with the current rules and regulations of the country where the product is installed. . Nordpeis AS is not responsible for wrongly assembled stoves. 0,78 The illustrations indicate the approximate centre height of the recess for the ue.
  • Page 4: Distance To Combustible Material

    10/17 mm wrench (included) • Screwdriver FIG 17- FIG 21 - Uno 1, 2, 4, 5 FIG 22 - Uno 5. Uno 1: Remove the screws holding the back cover FIG 17. Carefully tilt the bottom plate through the door on the pedestal.Remove the back cover to acess det...
  • Page 5 The CE-mark which is included should be placed on the 2) before you close the door. Additional ignition air is stove. Uno 1: The CE mark should be placed on the supply is regulated with the air vent control. back of the pedestal.
  • Page 6: Maintenance

    After this, replacements can be purchased. If new plates are needed, contact your dealer: Uno 1, 2, 4, 5 - FIG 11: the Manufacturer. B. Backplate C. Bottom plate + Uno 5 - FIG 11A: are prohibited.
  • Page 7 amount of wood. Too many logs put on hot ember, may result in combustion air starvation, and the gases will be released unburnt. For this reason it is important to briquettes and dry kindling wood. Newspapers cause a increase the air supply just after adding logs. lot of ash and the ink is damaging for the environment.
  • Page 8 se of combustion problems Error Solution The chimney is blocked Contact a chimney sweeper / dealer for more information or clean Downdraught in the room caused by no draught, that the must be installed in the room. central ventilation system that pulls too much air out of more vents must be installed.
  • Page 9 FIG 1 Uno 1, 2, 4 >300 >500 >50 >250 >785 >795 >655 * m/isolert røykrør * w/insulated smokpipe * mit isoliertem Rauchrohr >800 nationales concernant les distances d’installation par fumées * m/isolerat rökrör...
  • Page 10 FIG 1a Uno 5 >(150*) >300 >50 >150 >785 >795 >655 * m/isolert røykrør * w/insulated smokpipe * mit isoliertem Rauchrohr >900 nationales concernant les distances d’installation par fumées * m/isolerat rökrör...
  • Page 11 Uno 1 =mm...
  • Page 12 Uno 1 =mm AIR...
  • Page 13 Uno 2 =mm...
  • Page 14 Uno 2 =mm AIR...
  • Page 15 Uno 4 =mm...
  • Page 16 Uno 4 =mm AIR...
  • Page 17 Uno 5 =mm...
  • Page 18 Uno 5 =mm AIR...
  • Page 19 FIG 2 FIG 3 FIG 4 FIG 5...
  • Page 20 FIG 7 FIG 6 FIG 9 FIG 8...
  • Page 21 FIG 10 FIG 11 FIG 11A FIG 12...
  • Page 22 FIG 13 FIG 14...
  • Page 23 FIG 15 FIG 16 FIG 18 FIG 17...
  • Page 24 FIG 19 FIG 20 FIG 21...
  • Page 25 FIG 22 FIG 23 FIG 24...
  • Page 26 PLASSERING AV SERIENUMMER / POSITION OF THE SERIAL NUMBER POSITION DER SERIENNUMMER / POSITION DU NUMÉRO DE SÉRIE PLACERING AV SERIENUMMER / SARJANUMERON SIJAINTI...
  • Page 27 Nordpeis AS Gjellebekkstubben 11 3420 Lierskogen, Norway UNO 1, 2, 4 EN 13240:2001/A2:2007 Heating of living accomodation / Kamin zum Heizen mit festen Brennstoffen Year of Approval / Zulassungsjahr 2013 Fire safety: Feuersicherheit : Reaction to fire: A1 WT Brandverhalten:...
  • Page 28 Nordpeis AS Gjellebekkstubben 11 3420 Lierskogen, Norway UNO 5 EN 13240:2001/A2:2004 Heating of living accomodation / Kamin zum Heizen mit festen Brennstoffen Year of Approval / Zulassungsjahr 2016 Fire safety: Feuersicherheit : Reaction to fire: Brandverhalten: A1 WT Distance to combustible:...
  • Page 29 Permanent pilot flame power requirement Pilot flame power requirement (if applicable) Contact details Name and address of the supplier: Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway...
  • Page 30 Nordpeis AS. Nordpeis UNO ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE 2015/1186...
  • Page 31 Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway www.nordpeis.no...

This manual is also suitable for:

Uno 2Uno 4Uno 5