Warranty
ELECTRONIC AIR CLEANER LIMITED THREE-YEAR WARRANTY
This limited warranty covers Trion Residential Type Electronic Air Cleaners, excluding ductwork,
wiring and installation. Trion warrants that all new Trion Electronic Residential Air Cleaners are
free from defects in material and workmanship under normal, noncommercial use and service.
Trion will remedy any such defects if they appear within 36 months from the date of original
installation as evidenced by Proof of Purchase from an Authorized Trion Dealer, subject to terms
and conditions of the Limited Three-Year Warranty stated below:
1. THIS LIMITED THREE-YEAR WARRANTY IS GRANTED BY CARECO, 415 WABASH AVE., P .O.
BOX 200, EFFINGHAM, IL 62401.
2. This warranty shall extend only to any noncommercial owner who has purchased the
residential Electronic Air Cleaner other than for purposes of resale.
3. All components are covered by this limited warranty except expendable items such as
charcoal filters.
4. If within the warranty period, any Trion residential Electronic Air Cleaner unit or component
requires service, it must be performed by a competent heating and or air conditioning
contractor (preferably the installing contractor). CareCo will not pay shipping charges or
labor charges to remove or replace such defective parts or components. If the part or
component is found by inspection to contain such defective material and workmanship, it
will be either repaired or exchanged free of charge at CareCo's option, and returned freight
collect.
5. In order to obtain the benefits of this limited three-year warranty, the owner must notify the
dealer or distributor in writing or by phone, of any defect within 30 days of its discovery. If
after reasonable time you have not received an adequate response from the dealer or
distributor, notify in writing, by phone, or email: CareCo Warranty, 415 Wabash Avenue
Effingham, IL 62401 or e:mail to: fiaqcustomerservice@fedders.com
6. This limited warranty does not apply to any part or component that is damaged in transit or
when handling, has been subject to misuse, neglect or accident, has not been installed,
operated and serviced according to Fedders Unitary Product's instruction, has been operated
beyond the factory rated capacity, or altered in any such way that its performance is affected.
There is no warranty due to neglect, alteration or ordinary wear and tear. Fedders Unitary
Product's liability is limited to the replacement of defective parts or components and does
not include the payment cost of labor charges to remove or replace such defective parts.
7. CARECO WILL NOT BE RESPONSIBLE FOR LOSS OF USE OF ANY PRODUCT, LOSS OF TIME,
INCONVENIENCE, OR ANY OTHER INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
WITH RESPECT TO PERSON OR PROPERTY, WHETHER AS A RESULT OF BREACH OF
WARRANTY, NEGLECT OR OTHERWISE. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR
EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU.
8. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.
9. Any warranty (express, implied or statutory), representation, or guarantee other than those
set forth herein, shall expire at the expiration date, of this express limited warranty. SOME
STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO
THE LIMITATION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU.
10. Fedders Unitary Products reserves the right to make changes in the design and material of
its products without incurring any obligation to incorporate such changes in units completed
on the effective date of such a change.
415 Wabash Ave., P .O. Box 200, Effingham, IL 62401,
Phone: 1-866-829-2440
email: fiaqcustomerservice@fedders.com
CareCo
26
HE Plus 1400
HE Plus 2000
Duct Mount
Electronic Air Cleaner
Installation • Operation • Maintenance
CAUTION:
READ INSTALLATION, OPERATION, AND MAINTENANCE
INSTRUCTIONS CAREFULLY FOR SAFE OPERATION.
EXERCISE EXTREME CAUTION WHEN WORKING WITH
ELECTRICITY.
155587-001 07-04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HE Plus 1400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trion HE Plus 1400

  • Page 1 Trion will remedy any such defects if they appear within 36 months from the date of original installation as evidenced by Proof of Purchase from an Authorized Trion Dealer, subject to terms and conditions of the Limited Three-Year Warranty stated below: 1.
  • Page 2: Table Of Contents

    Secondary Circuit – Ionizing-Collecting Cell ...22 Secondary Circuit – Power Supply ...23 Unit Diagram & Parts List ...25 Warranty ...26 Ref. Description HE Plus 1400 (16” x 25”) Power Tray Assembly 120/50-60/1 455578-001 Power Tray Assembly 240/50-60/1 455578-008 High Frequency Power Supply*...
  • Page 3: Troubleshooting

    Troubleshooting For Qualified HVAC Installer Only 10. If no voltage is present, remove the second cell. Install cell number one and measure voltage as described in step #7. If voltage is present, the second cell, which is now out of the cabinet, is shorted.
  • Page 4: Unit Components

    Unit Components Cabinet Mounts to existing ductwork; houses the Ionizing-Collecting Cells and Pre-filters. Ionizing-Collecting Cells Collect the dust, dirt and other particulates in the air. They contain the ionizing and collecting sections. The cells must be installed with the ionizing wires on the air intake side. A spring contact is located on the top of each cell and must be in the position to make contact with the contact board assemblies on the bottom of the Power Tray Assembly.
  • Page 5: Operation

    Troubleshooting For Qualified HVAC Installer Only SECONDARY CIRCUIT IONIZING-COLLECTING CELL The cells are electrically energized through a contact terminal located at the top center of each cell. The ionizing wires and alternating collector plates are electrically charged while the interleaving plates are grounded. If the space between the charged and grounded plates is bridged with conductive or semi-conductive material, a short circuit develops.
  • Page 6: High Altitude Operation

    Operation High Altitude Operation Because the air is less dense at higher altitudes, there is a possibility of nuisance arcing in the Electronic Air Cleaner. The homeowner can quickly and easily correct this condition. Make sure the HVAC System Blower is not operating, the ON/OFF switch is in OFF position and the circuit breaker is turned OFF or input power cord is disconnected.
  • Page 7: Maintenance Of Your Electronic Air Cleaner

    Troubleshooting For Qualified HVAC Installer Only TROUBLESHOOTING WARNING: • These procedures must be performed by a qualified HVAC technician or electrician. • Risk of personal injury or death could occur by attempting to troubleshoot or repair this unit by untrained persons. •...
  • Page 8: Replacing The Ionizer Wires

    Maintenance REPLACING THE IONIZING WIRES Instances of the Ionizing Wires breaking are minimal due to the constant tension design and fixed location of the Ionizing Wire supports. When an Ionizing Wire breaks, the efficiency of the Electronic Air Cleaner will decrease slightly. However, the unit will continue to operate with a broken Ionizing Wire as long as the broken wire has not caused a short in the secondary circuit of the unit.
  • Page 9: Electrical Installation

    Installation For Qualified HVAC Installer Only ELECTRICAL INSTALLATION CAUTION If the Electronic Air Cleaner is wired directly to the integrated accessory control on the furnace, it is imperative that the ampere rating of the control be sufficient to handle the current required by the air cleaner.
  • Page 10 Q & A Q. I lost power to my home during a storm. Should I worry about the Electronic Air Cleaner ? The most common problem associated with power outages is the Electronic Air Cleaner will not turn on properly after power is restored. If the Green INPUT POWER indicating light is illuminated, and the Red CELL ENERGIZED indicating light is illuminated while the HVAC system blower is operating, the unit is operating properly.
  • Page 11: Common Troubleshooting Techniques

    Installation For Qualified HVAC Installer Only INSTALLATION CAUTION: Only a trained, experienced servicer should install this Electronic Air Cleaner. The Front Panel Assembly, Power Tray Assembly, Ionizing-Collecting Cells and Pre-filters should be removed before installation. To remove the Power Tray Assembly, remove the two (2) screws from inside the top front of the cabinet.
  • Page 12: Unit Dimensions

    Unit Dimensions EAC20002025 EAC14001625 EAC14002020 TYPICAL MOUNTING POSITIONS (Air cleaner shown shaded in illustrations) WARNING Before making changes to a HVAC system that affect ventilation fuel-burning appliances, contact your heating contractor. Transitions Transitions Basement Furnace Counterflow (Lowboy) – Mounted Furnace – Mounted horizontally in return horizontally in...
  • Page 13: Hvac Installation Instructions

    INSTALLER HELP LINE If you have any questions on installation issues or problems, please call Technical Support 866-829-2440 Technical Specifications Model HE Plus 1400 HE Plus 1400 Size (16x25) (20x20) Part Number 120V/50-60Hz 455601-001...
  • Page 14: Installation Considerations

    Installation For Qualified HVAC Installer Only Application The air cleaner is used in forced air heating, cooling and ventilating systems. It should be installed in the system such that all the system air is circulated through the air cleaner. The air cleaner will only remove the airborne contaminants delivered to it;...