Error Mode; Excess Angle - Lippert Components LCI Level-Up Owner's Manual

Motorhome leveling (2013-present)
Hide thumbs Also See for LCI Level-Up:
Table of Contents

Advertisement

All normal functions will be disabled when the system is in Error Mode.
1.
Auto Level can only commence if running voltage is 12.7V DC or above.
2.
Auto Level operation will halt if running voltage drops to 9.5V DC.
3.
Manual Level operation can be performed at all running voltages above 9.5V DC.
If an error occurs before or during operation, the error will be displayed in the LCD screen (Fig. 1E) and an
alarm will sound. To reset all error or service displays, press RETRACT and ENTER buttons (Fig. 1D and C) at
the same time. Refer to Touchpad Error Codes chart.

Excess Angle

Error Text
Excess Angle
Feature Disabled
External Sensor
Out of Stroke
Low Voltage
Function Aborted
Jack Timeout
Auto Level Fail
Not Configured
Zero Not Set
Battery Voltage
Apply Park Brake to Auto Level
Unit has retracted for longer than 50 seconds
Unable to Finish Leveling
Check Wiring
Caution, Excess Run Time
Latched Retract/Service
1.
The control will not operate at extreme slopes i.e., 3.5 degrees front and rear and 3.5 degrees
side-to-side.
2.
If the coach indicates "EXCESS ANGLE" or "JACKS STROKED OUT" during an auto level cycle, move the
coach to a more level spot.
Rev: 11.18.19
Touchpad Error Codes
Description
Excess slope for auto leveling.
Control not zeroed.
Remote sensor short or disconnected.
Check campsite for even, level ground and turn engine on - Check
battery voltage under load.
Turn engine on - Check battery voltage under load.
Panic stop.
Auto mode/Retract timeout.
Unable to level.
Control not zeroed.
Control not zeroed.
Turn engine on - Check battery voltage under load.
Set parking brake.
Retract timeout, return leveling jacks for service. Latched retract mode.
Move coach to a more level site.
Touchpad is powered, but not communicating with the controller.
Check pin 1 and 2 of touchpad harness.
Pump run too long in manual mode.
Check for leaking jack hose or fitting, reset by pressing retract and
enter at the same time.
Page 13
CCD-0001535

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LCI Level-Up and is the answer not in the manual?

Questions and answers

Michael M Silvers
April 14, 2025

I have a 2015 FLS337 cougar 5th wheel and I have no power to the touchpad for the leveling system. All the troubleshooting says is, Tripped breaker or turn the key on. Where is the breaker for that system?

Table of Contents

Save PDF