    RMD10T, RMD10XT Explanation of symbols Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it. NOTE You can find details on the operation in the manual.
  • Page 4: Safety Instructions

    Safety instructions RMD10T, RMD10XT Safety instructions The manufacturer accepts no liability for damage in the following cases: • Faulty assembly or connection • Damage to the product resulting from mechanical influences and incorrect connection voltage • Alterations to the product without express permission from the manufacturer •...
  • Page 5 RMD10T, RMD10XT Safety instructions CAUTION! Failure to obey these cautions could result in minor or moderate injury. Electrical shock • Before starting the device, ensure that the power supply line and the plug are dry. Risk of crushing • Do not put your fingers into the hinge. NOTICE! Damage hazard •...
  • Page 6 Safety instructions RMD10T, RMD10XT Standard AS 4555 safety WARNING! • The appliance may be installed by authorised personnel only! • The unit and the exhaust duct system must be in principle installed so tat it is accessible for maintenance work, can easily installed and dis- mantled and removed from the vehicle without great effort.
  • Page 7: Accessories

    Accessories Description Dometic gas flue kit 3776 Single lipped sealing for draft-proof installation for gaps of 1 – 5 mm (fig. 8 B, page 15) Double lipped sealing for draft-proof installation for gaps of 5 – 10 mm (fig. 8 C, page 15)
  • Page 8 • The refrigerator may not be installed in the rear of motor homes with the door pointing in the direction of travel. • Use exclusively original Dometic ventilation grills to ensure safe operation. When installing the refrigerator, note the following: •...
  • Page 9 RMD10T, RMD10XT Installing the refrigerator • The refrigerator must be installed in a recess so that it stands secure when the vehicle is in motion. Note the dimensions in fig. 1 for this purpose. Refrigerator Overall dimension in mm RMD10.5T RMD10.5XT Height (A) 1260...
  • Page 10 Installing the refrigerator RMD10T, RMD10XT • The outer wall must be fitted with an air inlet vent (fig. 2 1) and an outlet vent (fig. 2 2) with ventilation grills so that the heat generated can be easily released to the outside: –...
  • Page 11 RMD10T, RMD10XT Installing the refrigerator 15 – 25 mm >25 mm >25 mm • The distance between the refrigerator and the rear wall must be at least 15 mm but no more than 25 mm. • A distance of more than 25 mm between the refrigerator and rear wall leads to poor performance and increases the power consumption of the refrigerator.
  • Page 12 Installing the refrigerator RMD10T, RMD10XT 15 – 25 mm • If the minimum distance between the air inlet and outlet vents cannot be met, a roof vent must be installed instead of the air outlet vent. – The roof vent should be installed directly above the back of the refrigerator as far as this is possible.
  • Page 13 RMD10T, RMD10XT Installing the refrigerator ≥ 300 mm – If a roof air conditioner is provided, the distance between the roof vent (fig. 6 1) and the air outlet of the roof air conditioner (fig. 6 2) must be at least 300 mm.
  • Page 14 Installing the refrigerator RMD10T, RMD10XT Installing the refrigerator in a draft-proof location WARNING! Fire hazard! • Do not use flammable materials such as silicone sealants, foam or similar for the draft-proof installation. • Position the device so that no connection cable is damaged or pinched.
  • Page 15 RMD10T, RMD10XT Installing the refrigerator < 5 mm (< 0.2 in.) 5 mm - 10 mm (0.2 in. – 0.39 in.) ➤ B: For a side gap distance of up to 5 mm, glue the single lipped sealing (accessory) on the side of the cabinet behind the refrigerator (fig. 8 B). ➤...
  • Page 16 Installing the refrigerator RMD10T, RMD10XT ➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of 249 mm x 490 mm. When doing so, observe the information, see chapter “Preparing the installation” on page 8. If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the niche, install an inlet vent in the floor.
  • Page 17 RMD10T, RMD10XT Installing the refrigerator Installing the ventilation grill NOTE Use exclusively original Dometic ventilation grills to ensure safe opera- tion. No. in fig. 0 Description Slider Ventilation grill Installation frame Fastening for condensation drain ➤ Seal the installation frame to make the connection waterproof (fig. a).
  • Page 18 Installing the refrigerator RMD10T, RMD10XT ➤ Insert the installation frame and screw it down tightly (fig. b). Use all the fixing holes for this. ➤ Insert the ventilation grill as shown (fig. c). Installing condensation drain NOTE • Condensation can form inside the refrigerator due to frequent door opening, incorrectly stored food or food that is stored when it is too warm.
  • Page 19 RMD10T, RMD10XT Installing the refrigerator Install the roof vent No. in fig. d Description Hood Installation frame ➤ Seal the installation frame to make the connection waterproof (fig. e). ➤ Insert the installation frame and screw it down tightly (fig. f). Use all the fixing holes for this.
  • Page 20 ➤ Insert the hood and screw it down tightly (fig. g). Installing the flue duct NOTE • Install the Dometic gas flue kit 3776. Contact the customer service (see back page). • Do not install an additional flue stack, as this leads to poor perfor- mance and increases the power consumption of the refrigerator.
  • Page 21 RMD10T, RMD10XT Installing the refrigerator Install the flue duct as follows: min. 15 mm ➤ Make a rectangular opening in the outer wall of the vehicle (fig. i). – The opening must be as wide as the flue pipe (fig. h 3). –...
  • Page 22 Installing the refrigerator RMD10T, RMD10XT ➤ Attach the cover for the flue stack outside on the vehicle (fig. k). Securing the refrigerator CAUTION! Only screw through the receptacles provided, otherwise foamed com- ponents, such as cables, can be damaged. NOTE Attach the side walls or the attached strips so that the screws are tight, even when under increased loads (while driving).
  • Page 23: Connecting The Refrigerator

    RMD10T, RMD10XT Connecting the refrigerator ➤ Fasten the six screws (fig. l 1) through the six plastic washers in the sides of the refrigerator, and further into the wall. ➤ Put the caps (fig. l 2) onto the screw heads. Connecting the refrigerator Connecting to the gas supply NOTICE!
  • Page 24 Connecting the refrigerator RMD10T, RMD10XT ➤ Connect the refrigerator securely by hand to the gas supply (fig. m): Please note the following information: Item in Description fig. m Screw M4 (Torx TX20), Tightening torque: 2 Nm Gas valve shut-off cock Refrigerator gas connection: Rp1/8"-28 ➤...
  • Page 25 RMD10T, RMD10XT Connecting the refrigerator Connecting to DC and AC NOTICE! • The electrical installation and repairs may only be performed by a specialist in accordance with the applicable regulations and stand- ards. • DC connection to the heating element must be made to the vehicle engine battery, connection only while engine is running (fig.
  • Page 26 Connecting the refrigerator RMD10T, RMD10XT 23 24 25 B A D...
  • Page 27 RMD10T, RMD10XT Connecting the refrigerator ➤ Connect the refrigerator according to fig. o, page 26. Item in Description fig. o Fan 2 (if options module is not available) Fan 1 (if options module is not available) S+ (optional) Heating element DC 12 V relay with 20 A fuse for heating cartridge NTC 1: Refrigeration room NTC 2: Outside temperature (optional)
  • Page 28 Connecting the refrigerator RMD10T, RMD10XT DC power WARNING! Fire hazard! • The supply line to the heating element must be protected with a 20 A fuse. • The supply line to the electronics must be protected with a 2 A fuse. NOTICE! •...
  • Page 29 RMD10T, RMD10XT Connecting the refrigerator AC power ➤ Connect the refrigerator to an AC socket using the device plug. Alternative connection methods for DC power supply Refrigerator DC connections Electronics Heating DC House Battery Anderson Plug Anderson cables must be the recommended size.
  • Page 30 Connecting the refrigerator RMD10T, RMD10XT Refrigerator DC connections Electronics Heating DC Fridge House Battery Switch Anderson Plug Anderson cables must be the Vehicle Anderson plug must recommended size. be controlled by ignition relay. Using a fridge movement switch to add 12 Vg to the D+ connection wire, only when the vehicle is moving.
  • Page 31 RMD10T, RMD10XT Connecting the refrigerator Refrigerator DC connections Electronics Heating DC House Battery Anderson Plug Anderson cables must be the Vehicle Anderson plug must recommended size. be controlled by ignition relay. Anderson plug recharging the house battery via a power diode. The D+ wire can only get a 12 V signal when the battery is being charged.
  • Page 32: Technical Data

    4.2 kWh/24 h (230 Vw) Gas consumption: 522 g/24 h Gas connecting pressure: 2.75 kPa Climate class: Batteries (optional): 12 x AA 1.5 V fig. 1, page 8 Dimensions H x W x D: Weight: 43.9 kg 45.5 kg Inspection/certification: Detailed information dometic.com...