For C5 flues, exhaust gas and clean air terminals
must be installed on the counter walls of the
building.

3.6 Electrical connection

In order for the appliance to work in a healthy way
and for the electrical safety to be perfect, power
line to which the appliance is connected should be
strictly grounded.
Connect the appliance to the 220 ~ 230 V mono-
phase grounded power line with three-way cable
by connecting a 2 Amp. protector fuse (V- automat)
and paying attention to the phase/neutral poles.
Minimum operating voltage of the appliance is
195 V; maximum operating voltage is 253 V. In or-
der to minimize the effects of the supply values
over this range or the voltage fluctuations in the
mains line on the appliance, it is recommended
that a regulator is used.
Use a double-pole switch with a minimum 3 mm
distance between both poles.
When changing the supply cable, use HAR H05
VV-F' 3x0.75 cable with a maximum diameter of
8 mm.
B
Before performing a procedure on
the appliance, power should be dis-
connected.
Combi Boiler / User Manual
3.7 Pump capacity curve
L
2
BK 20 HP LCD
5,5
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
BK 26 HP LCD
7
6
5
4
3
2
1
0
0
Graphic 2
0
200
400
600
200
400 600 800 1000
Flowrate (I/h)
800
1000
1200
1200 1400 1600 1800 2000
29 / EN