Operation Of Battery Disconnect Switch - Komatsu PC360LCi-11 Operation & Maintenance Manual

Hydraulic excavator
Table of Contents

Advertisement

OPERATION
Fuse 2
Fuse ca-
No.
pacity
ICT sensor controller, work equipment con-
(1)
5 A
troller, voice amplifier
(2)
20 A
GNSS receiver, control box
(3)
10 A
Spare
(4)
10 A
Spare
(5)
10 A
Spare
(6)
5 A
IMU
(7)
5 A
Solenoid valve
(8)
20 A
Solenoid valve
(9)
20 A
Boom secondary drive switch
(10)
10 A
Spare
REMARK
Spare fuses are installed in the back of the fuse holder lid
at the rear of the operator's seat.
After using spare fuses, replenish them immediately.
One spare fuse is installed for each 5 A, 10 A, 15 A, 20 A,
25 A, and 30 A.
OPERATION OF BATTERY DISCONNECT SWITCH (FOR LOCKOUT/TAGOUT
REGULATED REGIONS)
Disconnect-switch can be locked out at the position where
switch-key(3) position is OFF using hasp (1) (Vehicle accesso-
ries) & padlock (2).
NOTICE
Prepare an appropriate padlock (2) by yourself in ad-
vance.
If you lost hasp(1)(Vehicle accessories) , please pur-
chase KomatsuPart Number (17A-54-55280) or procure
locally.
Please perform the following checks before imple-
menting Lockout.
Lock out disconnect-switch with hasp(1) & pad-
lock(2), In the locked out state, check that the switch-
key(3) does not move to the ON position and the sys-
tem operation lamp(4) does not light up.
Name of circuit
EXPLANATION OF COMPONENTS
3-35