11. Specification

Supply
Power 3/ 6L model
Tank capacity 3/ 6L model
Max water pressure
Min water pressure
Max tank pressure
Ambient operating temperature
Approvals
* If pressure is above 0.42 MPa (4.2 bar) a pressure reducing valve is required.

12. Troubleshooting

Problem
Water and steam spitting from
the tap
Tank not heating and no LED
lights
Tank not heating and red light
flashing
Water dripping from the tap
Low flow from the tap
Low flow from the tap
Low flow from the tap
Dispensed water is too hot
22
230V ~ 50Hz
1.55/ 2.84 kW
3/ 6 litres
0.42 MPa (4.2 bar)*
0.1MPa (1 bar)
0.6 MPa (6 bar)
5 – 35°C
CE
Likely Fault(s)
This is normal but temperature
can be adjusted if desired. Water
temperature is set to 100°C.
Thermal cut out has tripped
Software error
Tap fault
Scale filter needs changing
Scale build up in tank
Aerator needs cleaning
Water temperature is set to
100°C
Solution
Turn temperature down to 98°C
on PC board. See Section 6
Reset using cut out button. See
Section 6
Contact Hyco
Contact Hyco
Replace scale filter cartridge. See
Section 8
Descale tank. See section 10
Unscrew, remove and clean
aerator
Turn temperature down to 98°C
on PC board. See Section 6