NTP-G298 Configure a Cisco Catalyst 2950 or Catalyst 3560 (Active and Standby) for a ONS 15454 Multishelf Node
NTP-G298 Configure a Cisco Catalyst 2950 or Catalyst 3560
(Active and Standby) for a ONS 15454 Multishelf Node
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
When Cisco Catalysts are used in a multishelf node configuration, the Cisco Catalysts can be used for other
applications as long as they do not interfere with the VLAN settings of the multishelf node configuration.
• The ONS 15454 works with any VLAN ID type. The ONS 15454 M6 works with public VLAN ID of
• Public and Private VLAN IDs are specified in the multishelf configuration of ONS 15454 node controller.
Procedure
Step 1
At the Cisco IOS command line interface (CLI) for the Catalyst switch, enter the following spanning tree
commands:
Example:
Switch(config)#
Switch(config)#
Switch(config)#
Step 2
Enter the following commands to configure Port 1:
Example:
Switch(config)#
Switch(config-if)#
Switch(config-if)#
Switch(config-if)#
Switch(config-if)#
Cisco ONS 15454 Hardware Installation Guide
152
This procedure uses Cisco IOS to configure the Cisco Catalyst 2950 or Cisco
Catalyst 3560 for a multishelf node configuration. For more information about
the Catalyst 2950 or Catalyst 3560, refer to the Catalyst 2950 or Catalyst 3560
product documentation.
None
NTP-G295 Connect the ONS 15454 Multishelf Node and Subtending Shelves to
a Catalyst 2950 or Catalyst 3560, on page 146
Required
Onsite or remote
Superuser
1 and private VLAN ID of 2.
spanning-tree mode rapid-pvst
no spanning-tree optimize bpdu transmission
spanning-tree extend system-id
interface FastEthernet0/1
switchport trunk encapsulation dot1q
switchport trunk allowed vlan
switchport mode trunk
switchport nonegotiate