Technical Faults, Possible Causes And Remedies - Schaudt Electrobloc EBL 208 S G Instruction Manual

Table of Contents

Advertisement

R
8110600 BA / EN
Instruction Manual Electrobloc EBL 208 S G
10

Technical faults, possible causes and remedies

If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, for example if you are abroad, you can have the Elec-
trobloc repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt
GmbH takes no liability for any resulting damage.
Fault
Living area battery is not
charged during 230 V
operation (battery voltage
constantly below 13.3 V)
The living area battery is
overloaded during 230
operation (battery voltage
in the red zone on the com-
bined measuring instru-
ment)
Starter battery is not
charged during 230 V
operation (battery voltage
constantly below 13.0 V)
Living area battery is not
charged during mobile
operation (battery voltage
below 13.0 V)
The living area battery is
overloaded during mobile
operation (battery voltage
in the red zone on the com-
bined measuring instru-
ment)
The refrigerator does not
work during mobile opera-
tion
Solar charger does not
work (power supply and
engine are off)
Possible cause
No mains voltage
Defective Electrobloc
Defective Electrobloc
No mains voltage
Defective Electrobloc
Defective alternator
No voltage at D+ input
Defective Electrobloc
Defective alternator
No power supply to the
refrigerator
Defective Electrobloc
Defective refrigerator
Solar charge regulator not
plugged in
Defective fuse or wiring
Defective solar charge reg-
ulator
Edition: 20.11.2018
Remedy
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Call customer service
Call customer service
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Call customer service
Have the alternator
checked
Have the fuse and wiring
checked
Call customer service
Have the alternator
checked
Have the fuse and wiring
checked
Call customer service
Have the refrigerator
checked
Plug in the solar charge
regulator
Have the fuse and wiring
checked
Have the solar charge reg-
ulator checked
9