Operation; Commissioning; General; Power Supply - HADEF 29/06 E Series Installation, Operating And Maintenance Instructions

Electric chain hoist ultra-low headroom configuration with monorail hand geared trolley with monorail electric trolley
Table of Contents

Advertisement

8

Operation

Pos: 12.2.1 /1_HADEF/8--BETRIEB Nur (E+P)/Allgemein/Elektro+Druckluft/04.Alle E @ 1\mod_1185781340750_52.docx @ 7412 @ @ 1
The following, important points must be observed when operating the equipment:
Read the safety instructions.
Never load the devices beyond their working load limit.
When changing the motor turning direction, allow the motor to come to a standstill first.
The prescribed maintenance intervals must be adhered to.
Pos: 12.2.2 /1_HADEF/8--BETRIEB Nur (E+P)/Allgemein/Elektro+Druckluft/04.Zusatz für Elektro @ 1\mod_1193041482179_52.docx @ 8072 @ @ 1
Observe the duty cycle, i.e. intermittent operation S4-40% ED (as per VDE 0530) means that in a period
of 10 minutes the motor can operate – no matter the height of the load – for 4 minutes. It is therefore
irrelevant whether the 4 minutes are continuous (i.e., in case of very high lifting heights) or are made in
intervals.
Pos: 12.2.3 /1_HADEF/8--BETRIEB Nur (E+P)/Allgemein/Elektro+Druckluft/04.Zusatz für Hebezeuge @ 1\mod_1193041504888_52.docx @ 8078 @ @ 1
The lifting tackle or the load must be securely attached to the hook and be seated at the bottom of the
hook. The safety catch must always be closed.
Pos: 12.2.4 /1_HADEF/---ALLGEMEIN/Hinweise/GEFAHR - Losreißen, Personentr.,schweb.Lasten, ex verboten (E+P) @ 0\mod_1176799462104_52.docx @ 4735 @ @ 1
DANGER!
It is not allowed:
pulling loose of stuck loads, dragging of loads and inclined pulling is not allowed.
in explosive atmosphere, except the unit is especially modified for it and marked by an indication label
to transport people
The device is not suitable for use on stages and in studios
persons must not stand under a suspended load
Pos: 13.1 /1_HADEF/9--INBETRIEBNAHME/*Ü1*/#. Kapitel - Inbetriebnahme @ 0\mod_1177486166685_52.docx @ 5393 @ @ 1
9

Commissioning

Pos: 13.2.1.1 /1_HADEF/9--INBETRIEBNAHME/Allgemein/Allgemein/01.Allgemein @ 0\mod_1172504961658_52.docx @ 355 @ @ 1
9.1

General

Should the unit be used in Germany:
Please observe the validated, national accident prevention regulations.
For other countries:
Inspections as above. Please observe the national rules and regulations and the instructions in this manual!
Pos: 13.2.1.2 /1_HADEF/---ALLGEMEIN/Hinweise/Prüfungen/HINWEIS - Prüfung durch befähigte Pesonen @ 0\mod_1177339966681_52.docx @ 5319 @ @ 1
NOTICE!
Hoists up to 1000 kg capacity and without motor-driven trolleys of hoisting unit must be tested by a "qualified
person" before putting into operation for the first time.
Hoists of 1000 kg capacity and up or with more than one motor-driven hoist movement; i.e. lifting and trolley
movement, must be tested by a "licensed qualified person" before putting in operation.
An exception is "hoists ready for operation" acc. validated national regulations with EU-declaration of
conformity.
Definition "qualified person" (former expert)
A "qualified person" has learned, due to occupational training and experience and the job that the person has
done, the skills needed to tests the material for one's work.
Definition "licensed qualified person" (former approved expert)
A "licensed qualified person" has, due through special occupational training, knowledge about testing of the
material for one's work and knows the national accident prevention regulations and other prescriptions and
technical regulations. This person must test the material for one's work regularly with regard to design and
kind of use. The license will be given to qualified person be the approved supervision authorities (ZÜS).
Pos: 13.2.2.1 /1_HADEF/9--INBETRIEBNAHME/Allgemein/Stromanschluss/02.Stromanschluss - Alle Kettenzüge + Winden @ 0\mod_1172566680881_52.docx @ 363 @ @ 1
9.2

Power supply

9.2.1
Mains connection
Hoist motor technical data can be found it in the "Technical data" chapter.
The following tables show the assignment of the fuses at 400 Volt 3-phase current.
Select connection cross-sections as per VDE 0100.
Put sleeves on the ends of the cables.
Insert the connection cable into the connection plug without strain.
14
5.52.180.00.01.07

Advertisement

Table of Contents
loading