Page 1
Firefly DE500 User Manual Version: 2.3 DE500/501 User Manual DIGITAL VIDEO OTOSCOPE THANK YOU FOR SELECTING A FIREFLY VIDEO OTOSCOPE To take full advantage of this product’s advanced capabilities, and to properly and safely use this product, please read the manual carefully.
Page 2
Firefly Global (www.fireflyglobal.com). Firefly Global assumes no responsibility for any injury, or for any illegal or improper use of the product, that may result from failure to use this product in accordance with the instructions, cautions, warnings, or indications for use published in this manual.
Firefly DE500 User Manual Version: 2.3 Table of Contents Introduction ........................ 4 Warnings & Cautions ....................5 Warning ..........................5 Caution ........................... 5 Check List ........................7 Nomenclature ......................8 Operation ........................9 Setting up the otoscope with specula: ..............9 Setting up the Software Application:...
Version: 2.3 NTRODUCTION The Firefly Otoscope System consists of a digital Otoscope, software application and a USB cable. Only a computer equipped with a free USB port is needed to use the system. The Firefly Otoscope System is designed for effective operation under a variety of conditions and typical video parameters are set at the factory.
In order to obtain optimum performance and ensure patient safety, thoroughly read this manual. Do not use the Firefly Otoscope if you notice any signs of damage to the components of the system. Contact customer service for immediate assistance.
Page 6
Firefly DE500 User Manual Version: 2.3 This product complies with current required standards for electromagnetic interference and should not present problems to other equipment or be affected by other devices. As a precaution, avoid using this device in close proximity to other equipment.
Firefly DE500 User Manual Version: 2.3 HECK Before starting, check that all the following items have been included with your product. If anything is missing, contact your dealer. Otoscope x 1pc Specula (S/M/L) x 3 sets Software Application CD USB cable x 1 pc...
Firefly DE500 User Manual Version: 2.3 PERATION : ETTING UP THE OTOSCOPE WITH SPECULA Only accepts original specula qualified for use with Firefly Otoscopes. Ensure a tight fit for proper operation. Plug the specula into the round concave ...
Firefly DE500 User Manual Version: 2.3 Setting up the Software Application: Prior to using the Firefly Otoscope for the first time, install the FireflyPro software application following the instructions provided with the installation CD. Connect to PC: Connect the Firefly Otoscope to the PC’s USB port Power the Device On:...
Firefly DE500 User Manual Version: 2.3 Using the Firefly Otoscope System: Brightness Adjustment: On left rear side of the otoscope, a knob allows the user to control the brightness of the LEDs: Backward Turn: Decrease Brightness Forward Turn: Increase Brightness ...
Firefly DE500 User Manual Version: 2.3 Using Focus: Based on the relative distance of the observed object, the focus wheel can be turned for a clear image. When a higher magnification is required, the focus wheel can be turned to the left (see below). If a larger field of view is required, the otoscope can be moved farther away and the wheel turned to the right.
Double-click the FireflyPro.exe icon on your computer desktop: Viewing the Images: FireflyPro software controls your Firefly Otocope. TheOtoscope communicates with the PC through the USB cable. The user can configure the video properties, review live images, capture images, record video clips and perform a variety of powerful measurement and documentation functions.
Firefly DE500 User Manual Version: 2.3 Tool bars The Tools bars enable quick access to the functions of FireflyPro software. The tool bars can be grouped into Control, Images and Device tool bar sets. Control tool bars: Icon Icon Name...
Firefly DE500 User Manual Version: 2.3 Device Tool bars: Icon Icon Name Function Description Device Connect Refresh image device connection Select available image devices, such as Dermatoscope Select a video format (default 640x480 YUY2)
Do not apply alcohol, chemicals, or water to the lens. Any liquids entering the optical assembly will damage internal components. Use a dry cloth to clean the Digital Firefly Otoscope System on a weekly basis. Recycling the System Components Within the EU Do not dispose of this product as unsorted municipal refuse.
Version: 2.3 Service Policy All repairs on products under warranty must be performed or approved by Firefly or its authorized resellers. Unauthorized repairs will void the warranty. In addition, whether or not covered under warranty, any product repair shall exclusively be performed by Firefly-certified service personnel.
Firefly DE500 User Manual Version: 2.3 PECIFICATIONS Item Specification Weight Approximately 100 g (0.22 lb) Length: 13.0 cm (5.2 inches) Dimensions (approximate) Height: 3.6 cm (1.5 inches) Width: 4.0 cm (1.6 inches) Power USB 5VDC, 150mA Protection against ingress of water IPXØ...
ARRANTY Limited Hardware Warranty (through distributors & resellers) Firefly Global hardware products come with a 1-year limited hardware warranty. The warranty is extended through Firefly Global authorized representatives and resellers. If you have a warranty claim, please contact the store, distributor, or website through which the product was purchased.
Page 21
How long does this limited hardware warranty last? The limited hardware warranty on all Firefly Global products begins on the date of the packing slip, invoice, or receipt. The warranty period is not extended if a warranted product or any parts are repaired or replaced.
Firefly DE500 User Manual Version: 2.3 ROUBLESHOOTING Frequently Asked Questions (FAQs): Q1. What do I do if my Firefly Otoscope and FireflyPro software suddenly stops working? Answer: Shutdown the Firefly Otoscope and disconnect the USB cable from the computer. Close the FireflyPro software.
Page 23
Firefly DE500 User Manual Version: 2.3 Q7. Why does the video stream appear like a mosaic and update slowly (or not smoothly)? Answer: a. Too many software programs may be running simultaneously and overloading the CPU, or the physical memory has reached its saturation. Please close unnecessary programs. If video stream doesn’t improve, please reboot the system in order to release previously used memory.
Need help?
Do you have a question about the DE500 and is the answer not in the manual?
Questions and answers