DMP Electronics 9000 Series Installation And Programming Manual

Wireless keypads
Hide thumbs Also See for 9000 Series:

Advertisement

9000 Series Wireless Keypads
INSTALLATION AND PROGRAMMING GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DMP Electronics 9000 Series

  • Page 1 9000 Series Wireless Keypads INSTALLATION AND PROGRAMMING GUIDE...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS About the Keypad ........1 Program the Keypad Options ....12 What is Included ........... 1 Keypad Options ..........12 Keypad Features .........2 Custom Card Format ........ 14 Additional Programming (9063 only) ..21 Enter Characters .........3 Test the Keypad ........22 Enter Alpha Characters ........
  • Page 4 Compliance Specifications..... 36 Certifications ..........37 FCC Information ........38 Industry Canada Information ....39...
  • Page 5: About The Keypad

    • One wireless keypad mounted in a Thinline™ two-part housing (base and cover) • One internal rechargeable 3.7 V lithium battery • One 12 VDC DC Plug-in Power Supply • Built-in proximity card reader (9063 only) Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 6: Keypad Features

    KEYPAD FEATURES Select Keys Keypad Display/ Status List Panic Keys 1. Backlit Logo Command 2. Proximity (CMD) Key Credential Reader Back Arrow Key (9063 only) Figure 1: 9000 Series LCD Keypad 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 7: Enter Characters

    Each key has a non-alpha special character that is not shown on the keypad. Non-alphanumeric characters are entered into the keypad the same way as alphanumeric characters. See Figure 3. Figure 3: Keys with Non-Alpha Characters Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 8: System Components

    The keypads provide an alternate prewarn with alarm cadence that occurs when the status list displays a zone alarm. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 9: Backlighting

    Red Steady Panel Armed Primary Power OK, Battery OK Red/Green Alternate Panel Armed Primary Power OK, Battery Fault Red Blinking Panel Armed Primary Power Fault, Battery OK Table 1: Backlit Logo Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 10: User Options Menu

    At SET VOLUME LEVEL, use the left and right select keys to adjust the volume. Model Number Display the keypad model number, firmware version, and date. Serial Number Display Display the keypad serial number. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 11: Program The Keypad

    To enable association operation in XR150/XR550, XT30/XT50, and XTLplus/XTLtouch panels, reset the panel 3 times within 12 seconds. Allow the keypad bus Transmit/Receive LEDs to turn back on between each reset. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 12 The keypad logo turns green to indicate it has been associated with the panel. Selecting the Proper Location 9000 Series keypads provide a built-in survey capability in the Installer Options menu to allow one person to confirm keypad communication with the panel. For more information, see “Keypad Wireless Survey”.
  • Page 13: Install The Keypad

    Repeat with the other slot. Gently separate the cover from the base and set the cover containing the keypad components aside. See Figure 4 Figure 4: Separate the Keypad Housing Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 14: Mount The Keypad

    Surface and Backbox Mounting Holes Black (-) Black/White stripe (+) Combined 4-Square and 3-Gang Switch Box Mounting Holes Wall Tamper Surface and Backbox Mounting Holes Figure 5: Mounting Holes on Keypad Back 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 15: Power The Keypad

    3.62 VDC. To restore the keypad from a low battery state, the voltage must be above 3.62 VDC. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 16: Program The Keypad Options

    Keypad Options KPD KPD KPD To program keypad options, press KPD OPT. OPT DIAG RF STOP Serial Number The keypad displays the serial number of the keypad. SERIAL #:XXXXXXXX 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 17 The delay also occurs when any credential is presented for arming the Home/Sleep/Away system. Default is 2. ENABLE TAMPER? Enable Tamper? Select YES to enable wall tamper protection. Default is NO. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 18: Custom Card Format

    ZN 3 REX TIME. No user code information is sent to the panel. The menu advances to NO COMM WITH PNL. The default card format is DMP. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 19 SINGLE CARD FORMAT and WIEGAND CODE LENGTH will default to 45. Format Name FORMAT NAME Press any select area to rename the card format. Press CMD to *UNUSED* save and advance. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 20 Received Position = 0 Length = 8 Length = 16 Position = 25 In this example the Wiegand Code Length = 26 bits. Figure 7: Wiegand Data Stream Bit Location 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 21 0-255. Press CMD to save. Default is 9. Press select area 4 to clear the user code length and enter a number between 16-64. Press CMD to save. The default is the DMP value of 16. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 22 In the keypad display, enter site code 1 and press CMD. The display will ask for site code 2 followed by site code 3 and so on. When you have selected the site code you want to change, press CMD. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 23 All bits are read and converted into a decimal number string. The number string is left padded with 0 (zero) if needed for long user code lengths. Example: # decoded 1234567 10 digits 0001234567 4 digits 4567 Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 24 Press the first select key or area to choose LAST (Keep Last NO COMM WITH PNL State). The relay remains in the same state and does not LAST change when communication is lost. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 25: Additional Programming (9063 Only)

    Press any select key. Choose ADD. At ENTER CODE: -, present the credential to the reader. The keypad works by reading the user code from the data string sent by the access control reader. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 26: Test The Keypad

    Press and hold each key for two seconds. The key number being held appears in the display. Verify the correct number displays before testing the next key. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 27 Exiting the Installer Options When done, press CMD once to return to the Installer Options screen. Press the select key under STOP to exit the Installer Options function. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 28: End User Training

    END USER TRAINING This section covers: • Keypad Arming and Disarming • Keypad Entry Delay All of the examples displayed assume that CLOSING CODE is YES in panel programming. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 29: Keypad Arming And Disarming

    Select NO to arm or disarm individual areas. Select YES, or simply wait, to automatically arm or disarm all areas for which you are authorized. Figure 8: Area Arming and Disarming Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 30 If the system is disarmed when you present your card, once the card is validated, HOME SLEEP AWAY displays. Manually select HOME, SLEEP, AWAY or after a short time-out, all areas automatically arm in the AWAY mode. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 31: Keypad Entry Delay

    See Figure 9. ABC SECURITY ENTER CODE: – Entry delay starts. The system disarms the areas to which you are authorized. Figure 9: Entry Delay Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 32: Replace The Battery

    See Figure 10 Line up the PCB alignment post with the hole in the PCB. Press the PCB into the top PCB snaps to secure in place. Replace the base. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 33 Top PCB Snaps 4 Position Header PCB Alignment Post Bottom PCB Snaps Figure 10: PCB Snaps Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 34 Standby battery connector Black Figure 11: Battery Replacement 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 35: Public Card Formats

    LENGTH POSITION LENGTH POSITION LENGTH DIGITS H10301 26 BIT H10302 37 BIT W/O FAC H10304 37 BIT W/FAC FARPOINTE 39 BIT CORPORATE 1000 35 BIT CORPORATE 1000 48 BIT Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 36: Readers And Credentials

    PROXKEY III® ACCESS DEVICE READER 1351 PROXPASS® PP-6005B PROXPOINT® PLUS PROXIMITY READER 1386 ISOPROX II® CARD PR-5355 PROXPRO PROXIMITY READER WITH KEYPAD PR-5455 PROXPRO® II PROXIMITY READER TL-5395 THINLINE II® PROXIMITY READER 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 37 MIFARE® DESFIRE® EV2 SMARTCARD READER SMARTCARD DELTA5* SINGLE GANG BOX MOUNT CSK-2 MIFARE® DESFIRE® EV2 KEY SMARTCARD READER FOB SMARTCARD DELTA6.4* SMARTCARD READER WITH KEYPAD CSR-35P BLUETOOTH SMARTCARD READER Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 38: Ordering Information

    Wireless Thinline Keypad (white) 9060-W/699 Wireless Thinline Keypad with Deskstand (white) 9063-W Wireless Thinline Keypad with Prox Reader (white) 9063-W/699 Wireless Thinline Keypad with Prox Reader and Deskstand (white) 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 39: Accessories

    Keypad Backplate (plastic, 9” x 9”) Keypad Backplate (plastic, 7.4” x 11”) Keypad Deskstand (smoked plexiglass) 699-W Keypad Deskstand (white steel) Protective Keypad Cover Batteries 9000BAT/8 Replacement Standby Battery (8 pack) Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 40: Compliance Specifications

    7.00” W x 5.25” H x 0.50” D Color: White Housing Material Flame Retardant ABS Compatibility All 9000 Series keypads are compatible with all DMP panels and 1100 Series Wireless Receivers. Patents U.S. Patent No. 7,239,236 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 41: Certifications

    FCC Part 15 RFID Reader FCC ID: CCKPC0126 Industry Canada: 5251A-PC0126 Underwriters Laboratory (UL) Listed ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 985 Household Fire Warning System Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 42: Fcc Information

    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
  • Page 43: Industry Canada Information

    établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand public. Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide...
  • Page 48 LT-1107 20014 1.04 © 2019 Digital Monitoring Products, Inc.

This manual is also suitable for:

90609063

Table of Contents